Technical note: Comprehensive evaluations of gantry and couch rotation isocentricities for implementing proton stereotactic radiosurgery
Shen, Jiajian , Robertson, Daniel , Shipulin, K. N., Stoker, Joshua B., Ashman, Jonathan B. , Lara, Pedro, Keole, Sameer R., Wong, William W. , Vora, Sujay A., Robertson, Daniel G, Shipulin, Konstantin, Stoker, Joshua, Wong, William, Shen, Jiajian , Bues, Martin , Liu, Wei

Medical Physics | March 24, 2023 | Volume: 50 | Issue: 6 | Pages: 3359-3367

10.1002/mp.16382 Get It

AbstractBackgroundMechanical accuracy should be verified before implementing a proton stereotactic radiosurgery (SRS) program. Linear accelerator (Linac)‐based SRS systems often use electronic portal imaging devices (EPIDs) to verify beam isocentricity. Because proton therapy systems do not have EPID, beam isocentricity tests of proton SRS may still rely on films, which are not efficient.PurposeTo validate that our proton SRS system meets mechanical precision requirements and to present an efficient method to evaluate the couch and gantry's rotational isocentricity for our proton SRS system.MethodsA dedicated applicator to hold brass aperture for proton SRS system was designed. The mechanical precision of the system was tested using a metal ball and film for 11 combinations of gantry and couch angles. A more efficient quality assurance (QA) procedure was developed, which used a scintillator device to replace the film. The couch rotational isocentricity tests were performed using orthogonal kV x‐rays with the couch rotated isocentrically to five positions (0°, 315°, 270°, 225°, and 180°). At each couch position, the distance between the metal ball in kV images and the imaging isocenter was measured. The gantry isocentricity tests were performed using a cone‐shaped scintillator and proton beams at five gantry angles (0°, 45°, 90°, 135°, and 180°), and the isocenter position and the distance of each beam path to the isocenter were obtained. Daily QA procedure was performed for 1 month to test the robustness and reproducibility of the procedure.ResultsThe gantry and couch rotational isocentricity exhibited sub‐mm precision, with most measurements within ±0.5 mm. The 1‐month QA results showed that the procedure was robust and highly reproducible to within ±0.2 mm. The gantry isocentricity test using the cone‐shaped scintillator was accurate and sensitive to variations of ±0.2 mm. The QA procedure was efficient enough to be completed within 30 min. The 1‐month isocentricity position variations were within 0.5 mm, which demonstrating that the overall proton SRS system was stable and precise.ConclusionThe proton SRS Winston–Lutz QA procedure using a cone‐shaped scintillator was efficient and robust. We were able to verify radiation delivery could be performed with sub‐mm mechanical precision.
Robust intensity‐modulated proton therapy to reduce high linear energy transfer in organs at risk
An, Yu , Shan, Jie , Patel, Samir H. , Wong, William W. , Ding, Xiaoning, Bues, Martin , Wong, William, Schild, Steven E. , Bues, Martin , Liu, Wei

Medical Physics | October 4, 2017 | Volume: 44 | Issue: 12 | Pages: 6138-6147

10.1002/mp.12610 Get It

Purpose We propose a robust treatment planning model that simultaneously considers proton range and patient setup uncertainties and reduces high linear energy transfer (LET) exposure in organs at risk (OARs) to minimize the relative biological effectiveness (RBE) dose in OARs for intensity‐modulated proton therapy (IMPT). Our method could potentially reduce the unwanted damage to OARs. Methods We retrospectively generated plans for 10 patients including two prostate, four head and neck, and four lung cancer patients. The “worst‐case robust optimization” model was applied. One additional term as a “biological surrogate (BS)” of OARs due to the high LET‐related biological effects was added in the objective function. The biological surrogate was defined as the sum of the physical dose and extra biological effects caused by the dose‐averaged LET. We generated nine uncertainty scenarios that considered proton range and patient setup uncertainty. Corresponding to each uncertainty scenario, LET was obtained by a fast LET calculation method developed in‐house and based on Monte Carlo simulations. In each optimization iteration, the model used the worst‐case BS among all scenarios and then penalized overly high BS to organs. The model was solved by an efficient algorithm (limited‐memory Broyden–Fletcher–Goldfarb–Shanno) in a parallel computing environment. Our new model was benchmarked with the conventional robust planning model without considering BS. Dose–volume histograms (DVHs) of the dose assuming a fixed RBE of 1.1 and BS for tumor and organs under nominal and uncertainty scenarios were compared to assess the plan quality between the two methods. Results For the 10 cases, our model outperformed the conventional robust model in avoidance of high LET in OARs. At the same time, our method could achieve dose distributions and plan robustness of tumors assuming a fixed RBE of 1.1 almost the same as those of the conventional robust model. Conclusions Explicitly considering LET in IMPT robust treatment planning can reduce the high LET to OARs and minimize the possible toxicity of high RBE dose to OARs without sacrificing plan quality. We believe this will allow one to design and deliver safer proton therapy.
Proposed prognostic scoring system evaluating risk factors for biochemical recurrence of prostate cancer after salvage radiation therapy
Lee, Richard J. , Tzou, Katherine S., Hobbs, C., Rawal, Bhupendra, Diehl, Nancy N. , Peterson, Jennifer , Paryani, Nitesh N., Daugherty, Larry C., Vallow, Laura A., Wong, William W. , Pisansky, Thomas M. , Buskirk, Steven J., Hobbs, Corey J, Peterson, Jennifer L., Ko, Stephen J. , Wong, William, Schild, Steven, Heckman, Michael G. , Schild, Steven E.

BJU International | July 18, 2015 | Volume: 118 | Issue: 2 | Pages: 236-242

10.1111/bju.13229 Get It

Objective To update a previously proposed prognostic scoring system that predicts risk of biochemical recurrence ( BCR ) after salvage radiation therapy ( SRT ) for recurrent prostate cancer when using additional patients and a PSA value of 0.2 ng/ mL and rising as the definition of BCR . Patients and Methods We included 577 patients who received SRT for a rising PSA after radical prostatectomy in this retrospective cohort study. Clinical, pathological, and SRT characteristics were evaluated for association with BCR using relative risks ( RR s) from multivariable Cox regression models. Results With a median follow‐up of 5.5 years after SRT , 354 patients (61%) experienced BCR . At 5 years after SRT , 40% of patients were free of BCR . Independent associations with BCR were identified for the PSA level before SRT ( RR [doubling]: 1.25, P < 0.001), pathological tumour stage ( RR [T3a vs T2] 1.21, P = 0.19; RR [T3b/T4 vs T2] 2.09, P < 0.001; overall P < 0.001), Gleason score ( RR [7 vs <7] 1.63, P < 0.001; RR [8–10 vs <7] 2.28, P < 0.001; overall P < 0.001), and surgical margin status ( RR [positive vs negative] 0.71, P = 0.003). We combined these four variables to create a prognostic scoring system that predicted BCR risk with a c ‐index of 0.66. Scores ranged from 0 to 7, and 5‐year freedom from BCR for different levels of the score was as follows: Score = 0–1: 66%, Score = 2: 46%, Score = 3: 28%, Score = 4: 19%, and Score = 5–7: 15%. Conclusion We developed a scoring system that provides an estimation of the risk of BCR after SRT . These findings will be useful for patients and physicians in decision making for radiation therapy in the salvage setting.