AbstractBackgroundMechanical accuracy should be verified before implementing a proton stereotactic radiosurgery (SRS) program. Linear accelerator (Linac)‐based SRS systems often use electronic portal imaging devices (EPIDs) to verify beam isocentricity. Because proton therapy systems do not have EPID, beam isocentricity tests of proton SRS may still rely on films, which are not efficient.PurposeTo validate that our proton SRS system meets mechanical precision requirements and to present an efficient method to evaluate the couch and gantry's rotational isocentricity for our proton SRS system.MethodsA dedicated applicator to hold brass aperture for proton SRS system was designed. The mechanical precision of the system was tested using a metal ball and film for 11 combinations of gantry and couch angles. A more efficient quality assurance (QA) procedure was developed, which used a scintillator device to replace the film. The couch rotational isocentricity tests were performed using orthogonal kV x‐rays with the couch rotated isocentrically to five positions (0°, 315°, 270°, 225°, and 180°). At each couch position, the distance between the metal ball in kV images and the imaging isocenter was measured. The gantry isocentricity tests were performed using a cone‐shaped scintillator and proton beams at five gantry angles (0°, 45°, 90°, 135°, and 180°), and the isocenter position and the distance of each beam path to the isocenter were obtained. Daily QA procedure was performed for 1 month to test the robustness and reproducibility of the procedure.ResultsThe gantry and couch rotational isocentricity exhibited sub‐mm precision, with most measurements within ±0.5 mm. The 1‐month QA results showed that the procedure was robust and highly reproducible to within ±0.2 mm. The gantry isocentricity test using the cone‐shaped scintillator was accurate and sensitive to variations of ±0.2 mm. The QA procedure was efficient enough to be completed within 30 min. The 1‐month isocentricity position variations were within 0.5 mm, which demonstrating that the overall proton SRS system was stable and precise.ConclusionThe proton SRS Winston–Lutz QA procedure using a cone‐shaped scintillator was efficient and robust. We were able to verify radiation delivery could be performed with sub‐mm mechanical precision.
Technical Note: Integrating an open source Monte Carlo code “MCsquare” for clinical use in intensity‐modulated proton therapy
PurposeTo commission an open source Monte Carlo (MC) dose engine, “MCsquare” for a synchrotron‐based proton machine, integrate it into our in‐house C++‐based I/O user interface and our web‐based software platform, expand its functionalities, and improve calculation efficiency for intensity‐modulated proton therapy (IMPT).MethodsWe commissioned MCsquare using a double Gaussian beam model based on in‐air lateral profiles, integrated depth dose of 97 beam energies, and measurements of various spread‐out Bragg peaks (SOBPs). Then we integrated MCsquare into our C++‐based dose calculation code and web‐based second check platform “DOSeCHECK.” We validated the commissioned MCsquare based on 12 different patient geometries and compared the dose calculation with a well‐benchmarked GPU‐accelerated MC (gMC) dose engine. We further improved the MCsquare efficiency by employing the computed tomography (CT) resampling approach. We also expanded its functionality by adding a linear energy transfer (LET)‐related model‐dependent biological dose calculation.ResultsDifferences between MCsquare calculations and SOBP measurements were <2.5% (<1.5% for ~85% of measurements) in water. The dose distributions calculated using MCsquare agreed well with the results calculated using gMC in patient geometries. The average 3D gamma analysis (2%/2 mm) passing rates comparing MCsquare and gMC calculations in the 12 patient geometries were 98.0 ± 1.0%. The computation time to calculate one IMPT plan in patients’ geometries using an inexpensive CPU workstation (Intel Xeon E5‐2680 2.50 GHz) was 2.3 ± 1.8 min after the variable resolution technique was adopted. All calculations except for one craniospinal patient were finished within 3.5 min.ConclusionsMCsquare was successfully commissioned for a synchrotron‐based proton beam therapy delivery system and integrated into our web‐based second check platform. After adopting CT resampling and implementing LET model‐dependent biological dose calculation capabilities, MCsquare will be sufficiently efficient and powerful to achieve Monte Carlo‐based and LET‐guided robust optimization in IMPT, which will be done in the future studies.