AbstractBackgroundIn proton therapy dose calculation, Monte Carlo (MC) simulations are superior in accuracy but more time consuming, compared to analytical calculations. Graphic processing units (GPUs) are effective in accelerating MC simulations but may suffer thread divergence and racing condition in GPU threads that degrades the computing performance due to the generation of secondary particles during nuclear reactions.PurposeA novel concept of virtual particle (VP) MC (VPMC) is proposed to avoid simulating secondary particles in GPU‐accelerated proton MC dose calculation and take full advantage of the computing power of GPU.MethodsNeutrons and gamma rays were ignored as escaping from the human body; doses of electrons, heavy ions, and nuclear fragments were locally deposited; the tracks of deuterons were converted into tracks of protons. These particles, together with primary and secondary protons, are considered to be the realistic particles. Histories of primary and secondary protons were replaced by histories of multiple VPs. Each VP corresponded to one proton (either primary or secondary). A continuous‐slowing‐down‐approximation model, an ionization model, and a large angle scattering event model corresponding to nuclear interactions were developed for VPs by generating probability distribution functions (PDFs) based on simulation results of realistic particles using MCsquare. For efficient calculations, these PDFs were stored in the Compute Unified Device Architecture textures. VPMC was benchmarked with TOPAS and MCsquare in phantoms and with MCsquare in 13 representative patient geometries. Comparisons between the VPMC calculated dose and dose measured in water during patient‐specific quality assurance (PSQA) of the selected 13 patients were also carried out. Gamma analysis was used to compare the doses derived from different methods and calculation efficiencies were also compared.ResultsIntegrated depth dose and lateral dose profiles in both homogeneous and inhomogeneous phantoms all matched well among VPMC, TOPAS, and MCsquare calculations. The 3D–3D gamma passing rates with a criterion of 2%/2 mm and a threshold of 10% was 98.49% between MCsquare and TOPAS and 98.31% between VPMC and TOPAS in homogeneous phantoms, and 99.18% between MCsquare and TOPAS and 98.49% between VPMC and TOPAS in inhomogeneous phantoms, respectively. In patient geometries, the 3D–3D gamma passing rates with 2%/2 mm/10% between dose distributions from VPMC and MCsquare were 98.56 ± 1.09% in patient geometries. The 2D–3D gamma analysis with 3%/2 mm/10% between the VPMC calculated dose distributions and the 2D measured planar dose distributions during PSQA was 98.91 ± 0.88%. VPMC calculation was highly efficient and took 2.84 ± 2.44 s to finish for the selected 13 patients running on four NVIDIA Ampere GPUs in patient geometries.ConclusionVPMC was found to achieve high accuracy and efficiency in proton therapy dose calculation.
Exploratory study of seed spots analysis to characterize dose and linear‐energy‐transfer effect in adverse event initialization of pencil‐beam‐scanning proton therapy
AbstractBackgroundBoth dose and linear energy transfer (LET) could play a substantial role in adverse event (AE) initialization of cancer patients treated with pencil‐beam‐scanning (PBS) proton therapy. However, not all the voxels within the AE regions are directly induced from the dose and LET effect. It is important to study the synergistic effect of dose and LET in AE initialization by only including a subset of voxels that are dosimetrically important.PurposeTo perform exploratory investigation of the dose and LET effects upon AE initialization in PBS using seed spots analysis.MethodsA total of 113 head‐and‐neck (H&N) cancer patients receiving curative PBS were included. Among them, 20 patients experienced unanticipated CTCAEv4.0 grade ≥3 AEs (AE group) and 93 patients did not (control group). Within the AE group, 13 AE patients were included in the seed spot analysis to derive the descriptive features of AE initialization and the remaining 7 mandible osteoradionecrosis patients and 93 control patients were used to derive the feature‐based volume constraint of mandible osteoradionecrosis. The AE regions were contoured and the corresponding dose–LET volume histograms of AE regions were generated for all patients in the AE group. We selected high LET voxels (the highest 5% of each dose bin) with a range of moderate‐to‐high dose (≥∼40‐Gy relative biological effectiveness) as critical voxels. Critical voxels that were contiguous with each other were grouped into clusters. Each cluster was considered a potential independent seed spot for AE initialization. Seed spots were displayed in a 2D dose–LET plane based on their mean dose and LET to derive the descriptive features of AE initialization. A volume constraint of mandible osteoradionecrosis was then established based on the extracted features using a receiver operating characteristic curve.ResultsThe product of dose and LET (xBD) was found to be a descriptive feature of seed spots leading to AE initialization in this preliminary study. The derived xBD volume constraint for mandible osteoradionecrosis showed good performance with an area under curve of 0.87 (sensitivity of 0.714 and specificity of 0.807 in the leave‐one‐out cross‐validation) for the very limited patient data included in this study.ConclusionOur exploratory study showed that both dose and LET were observed to be important in AE initializations. The derived xBD volume constraint could predict mandible osteoradionecrosis reasonably well in the very limited H&N cancer patient data treated with PBS included in this study.
GPU‐accelerated Monte Carlo‐based online adaptive proton therapy: A feasibility study
AbstractPurposeTo develop an online graphic processing unit (GPU)‐accelerated Monte Carlo‐based adaptive radiation therapy (ART) workflow for pencil beam scanning (PBS) proton therapy to address interfraction anatomical changes in patients treated with PBS.Methods and MaterialsA four‐step workflow was developed using our in‐house developed GPU‐accelerated Monte Carlo‐based treatment planning system to implement online Monte Carlo‐based ART for PBS. The first step conducts diffeomorphic demon‐based deformable image registration (DIR) to propagate contours on the initial planning CT (pCT) to the verification CT (vCT) to form a new structure set. The second step performs forward dose calculation of the initial plan on the vCT with the propagated contours after manual approval (possible modifications involved). The third step triggers a reoptimization of the plan depending on whether the verification dose meets the clinical requirements or not. A robust evaluation will be done for both the verification plan in the second step and the reopotimized plan in the third step. The fourth step involves a two‐stage (before and after delivery) patient‐specific quality assurance (PSQA) of the reoptimized plan. The before‐delivery PSQA is to compare the plan dose to the dose calculated using an independent fast open‐source Monte Carlo code, MCsquare. The after‐delivery PSQA is to compare the plan dose to the dose recalculated using the log file (spot MU, spot position, and spot energy) collected during the delivery. Jaccard index (JI), dice similarity coefficients (DSCs), and Hausdorff distance (HD) were used to assess the quality of the propagated contours in the first step. A commercial plan evaluation software, ClearCheck™, was integrated into the workflow to carry out efficient plan evaluation. 3D Gamma analysis was used during the fourth step to ensure the accuracy of the plan dose from reoptimization. Three patients with three different disease sites were chosen to evaluate the feasibility of the online ART workflow for PBS.ResultsFor all three patients, the propagated contours were found to have good volume conformance [JI (lowest‐highest: 0.833–0.983) and DSC (0.909–0.992)] but suboptimal boundary coincidence [HD (2.37–20.76 mm)] for organs‐at‐risk. The verification dose evaluated by ClearCheck™ showed significant degradation of the target coverage due to the interfractional anatomical changes. Reoptimization on the vCT resulted in great improvement of the plan quality to a clinically acceptable level. 3D Gamma analyses of PSQA confirmed the accuracy of the plan dose before delivery (mean Gamma index = 98.74% with a threshold of 2%/2 mm/10%), and after delivery based on the log files (mean Gamma index = 99.05% with a threshold of 2%/2 mm/10%). The average time cost for the complete execution of the workflow was around 858 s, excluding the time for manual intervention.ConclusionThe proposed online ART workflow for PBS was demonstrated to be efficient and effective by generating a reoptimized plan that significantly improved the plan quality.
Per‐voxel constraints to minimize hot spots in linear energy transfer‐guided robust optimization for base of skull head and neck cancer patients in IMPT
AbstractPurposeDue to the employment of quadratic programming using soft constraints to implement dose volume constraints and the “trial‐and‐error” procedure needed to achieve a clinically acceptable plan, conventional dose volume constraints (upper limit) are not adequately effective in controlling small and isolated hot spots in the dose/linear energy transfer (LET) distribution. Such hot spots can lead to adverse events. In order to mitigate the risk of brain necrosis, one of the most clinically significant adverse events in patients receiving intensity‐modulated proton therapy (IMPT) for base of skull (BOS) cancer, we propose per‐voxel constraints to minimize hot spots in LET‐guided robust optimization.Methods and materialsTen BOS cancer patients treated with IMPT were carefully selected by meeting one of the following conditions: (1) diagnosis of brain necrosis during follow‐up; and (2) considered high risk for brain necrosis by not meeting dose constraints to the brain. An optimizing structure (BrainOPT) and an evaluating structure (BrainROI) that both contained the aforementioned hot dose regions in the brain were generated for optimization and evaluation, respectively. Two plans were generated for every patient: one using conventional dose‐only robust optimization, the other using LET‐guided robust optimization. The impact of LET was integrated into the optimization via a term of extra biological dose (xBD). A novel optimization tool of per‐voxel constraints to control small and isolated hot spots in either the dose, LET, or combined (dose/LET) distribution was developed and used to minimize dose/LET hot spots of the selected structures. Indices from dose‐volume histogram (DVH) and xBD dose‐volume histogram (xBDVH) were used in the plan evaluation. A newly developed tool of the dose‐LET‐volume histogram (DLVH) was also adopted to illustrate the underlying mechanism. Wilcoxon signed‐rank test was used for statistical comparison of the DVH and xBDVH indices between the conventional dose‐only and the LET‐guided robustly optimized plans.ResultsPer‐voxel constraints effectively and efficiently minimized dose hot spots in both dose‐only and LET‐guided robust optimization and LET hot spots in LET‐guided robust optimization. Compared to the conventional dose‐only robust optimization, the LET‐guided robust optimization could generate plans with statistically lower xBD hot spots in BrainROI (VxBD,50 Gy[RBE], p = 0.009; VxBD,60 Gy[RBE], p = 0.025; xBD1cc, p = 0.017; xBD2cc, p = 0.022) with comparable dose coverage, dose hot spots in the target, and dose hot spots in BrainROI. DLVH analysis indicated that LET‐guided robust optimization could either reduce LET at the same dose level or redistribute high LET from high dose regions to low dose regions.ConclusionPer‐voxel constraint is a powerful tool to minimize dose/LET hot spots in IMPT. The LET‐guided robustly optimized plans outperformed the conventional dose‐only robustly optimized plans in terms of xBD hot spots control.
Technical Note: Multiple energy extraction techniques for synchrotron‐based proton delivery systems may exacerbate motion interplay effects in lung cancer treatments
Abstract Purpose The multiple energy extraction (MEE) delivery technique for synchrotron‐based proton delivery systems reduces beam delivery time by decelerating the beam multiple times during one accelerator spill, but this might cause additional plan quality degradation due to intrafractional motion. We seek to determine whether MEE causes significantly different plan quality degradation compared to single energy extraction (SEE) for lung cancer treatments due to the interplay effect. Methods Ten lung cancer patients treated with IMPT at our institution were nonrandomly sampled based on a representative range of tumor motion amplitudes, tumor volumes, and respiratory periods. Dose‐volume histogram (DVH) indices from single‐fraction SEE and MEE four‐dimensional (4D) dynamic dose distributions were compared using the Wilcoxon signed‐rank test. Distributions of monitor units (MU) to breathing phases were investigated for features associated with plan quality degradation. SEE and MEE DVH indices were compared in fractionated deliveries of the worst‐case patient treatment scenario to evaluate the impact of fractionation. Results There were no clinically significant differences in target mean dose, target dose conformity, or dose to organs‐at‐risk between SEE and MEE in single‐fraction delivery. Three patients had significantly worse dose homogeneity with MEE compared to SEE (single‐fraction mean D 5% ‐D 95% increased by up to 9.6% of prescription dose), and plots of MU distribution to breathing phases showed synchronization patterns with MEE but not SEE. However, after 30 fractions the patient in the worst‐case scenario had clinically acceptable target dose homogeneity and coverage with MEE (mean D 5% –D 95% increased by 1% compared to SEE). Conclusions For some patients with breathing periods close to the mean spill duration, MEE resulted in significantly worse single‐fraction target dose homogeneity compared to SEE due to the interplay effect. However, this was mitigated by fractionation, and target dose homogeneity and coverage were clinically acceptable after 30 fractions with MEE.
Technical Note: 4D robust optimization in small spot intensity‐modulated proton therapy (IMPT) for distal esophageal carcinoma
Purpose To compare the dosimetric performances of small‐spot three‐dimensional (3D) and four‐dimensional (4D) robustly optimized intensity‐modulated proton (IMPT) plans in the presence of uncertainties and interplay effect simultaneously for distal esophageal carcinoma. Method and Materials Thirteen (13) patients were selected and re‐planned with small‐spot ( ~ 2–6 mm) 3D and 4D robust optimization in IMPT, respectively. The internal clinical target volumes (CTV high3d , CTV low3d ) were used in 3D robust optimization. Different CTVs (CTV high4d , CTV low4d ) were generated by subtracting an inner margin of the motion amplitudes in three cardinal directions from the internal CTVs and used in 4D robust optimization. All patients were prescribed the same dose to CTVs (50 Gy[RBE] for CTV high3d /CTV high4d and 45 Gy[RBE] for CTV low3d /CTV low4d ). Dose–volume histogram (DVH) indices were calculated to assess plan quality. Comprehensive plan robustness evaluations that consisted of 300 perturbed scenarios (10 different motion patterns to consider irregular motion (sampled from a Gaussian distribution) and 30 different uncertainties scenarios (sampled from a 4D uniform distribution) combined), were performed to quantify robustness to uncertainties and interplay effect simultaneously. Wilcoxon signed‐rank test was used for statistical analysis. Results Compared to 3D robustly optimized plans, 4D robustly optimized plans had statistically improved target coverage and better sparing of lungs and heart (heart D mean , P = 0.001; heart V 30Gy[RBE] , P = 0.001) in the nominal scenario. 4D robustly optimized plans had better robustness in target dose coverage (CTV high4d V 100% , P = 0.002) and the protection of lungs and heart (heart D mean , P = 0.001; heart V 30Gy[RBE] , P = 0.001) when uncertainties and interplay effect were considered simultaneously. Conclusions Even with small spots in IMPT, 4D robust optimization outperformed 3D robust optimization in terms of normal tissue protection and robustness to uncertainties and interplay effect simultaneously. Our findings support the use of 4D robust optimization to treat distal esophageal carcinoma with small spots in IMPT.
Beam angle comparison for distal esophageal carcinoma patients treated with intensity‐modulated proton therapy
Abstract Purpose To compare the dosimetric performances of intensity‐modulated proton therapy (IMPT) plans generated with two different beam angle configurations (the Right–Left oblique posterior beams and the Superior–Inferior oblique posterior beams) for the treatment of distal esophageal carcinoma in the presence of uncertainties and interplay effect. Methods and Materials Twenty patients’ IMPT plans were retrospectively selected, with 10 patients treated with the R‐L oblique posterior beams (Group R‐L) and the other 10 patients treated with the S‐I oblique posterior beams (Group S‐I). Patients in both groups were matched by their clinical target volumes (CTVs—high and low dose levels) and respiratory motion amplitudes. Dose‐volume‐histogram (DVH) indices were used to assess plan quality. DVH bandwidth was calculated to evaluate plan robustness. Interplay effect was quantified using four‐dimensional (4D) dynamic dose calculation with random respiratory starting phase of each fraction. Normal tissue complication probability (NTCP) for heart, liver, and lung was calculated, respectively, to estimate the clinical outcomes. Wilcoxon signed‐rank test was used for statistical comparison between the two groups. Results Compared with plans in Group R‐L, plans in Group S‐I resulted in significantly lower liver D mean and lung V 30Gy[RBE] with slightly higher but clinically acceptable spinal cord D max . Similar plan robustness was observed between the two groups. When interplay effect was considered, plans in Group S‐I performed statistically better for heart D mean and V 30Gy[RBE] , lung Dmean and V 5Gy[RBE] , and liver D mean , with slightly increased but clinically acceptable spinal cord D max . NTCP for liver was significantly better in Group S‐I. Conclusions IMPT plans in Group S‐I have better sparing of liver, heart, and lungs at the slight cost of spinal cord maximum dose protection, and are more interplay‐effect resilient compared to IMPT plans in Group R‐L. Our study supports the routine use of the S‐I oblique posterior beams for the treatments of distal esophageal carcinoma.
Intensity‐modulated proton therapy (IMPT) interplay effect evaluation of asymmetric breathing with simultaneous uncertainty considerations in patients with non‐small cell lung cancer
Purpose Intensity‐modulated proton therapy (IMPT) is sensitive to uncertainties from patient setup and proton beam range, as well as interplay effect. In addition, respiratory motion may vary from cycle to cycle, and also from day to day. These uncertainties can severely degrade the original plan quality and potentially affect patient’s outcome. In this work, we developed a new tool to comprehensively consider the impact of all these uncertainties and provide plan robustness evaluation under them. Methods We developed a comprehensive plan robustness evaluation tool that considered both uncertainties from patient setup and proton beam range, as well as respiratory motion simultaneously. To mimic patients' respiratory motion, the time spent in each phase was randomly sampled based on patient‐specific breathing pattern parameters as acquired during the four‐dimensional (4D)‐computed tomography (CT) simulation. Spots were then assigned to one specific phase according to the temporal relationship between spot delivery sequence and patients’ respiratory motion. Dose in each phase was calculated by summing contributions from all the spots delivered in that phase. The final 4D dynamic dose was obtained by deforming all doses in each phase to the maximum exhalation phase. Three hundred (300) scenarios (10 different breathing patterns with 30 different setup and range uncertainty scenario combinations) were calculated for each plan. The dose‐volume histograms (DVHs) band method was used to assess plan robustness. Benchmarking the tool as an application’s example, we compared plan robustness under both three‐dimensional (3D) and 4D robustly optimized IMPT plans for 10 nonrandomly selected patients with non‐small cell lung cancer. Results The developed comprehensive plan robustness tool had been successfully applied to compare the plan robustness between 3D and 4D robustly optimized IMPT plans for 10 lung cancer patients. In the presence of interplay effect with uncertainties considered simultaneously, 4D robustly optimized plans provided significantly better CTV coverage (D 95% , P = 0.002), CTV homogeneity (D 5% ‐D 95% , P = 0.002) with less target hot spots (D 5% , P = 0.002), and target coverage robustness (CTV D 95% bandwidth, P = 0.004) compared to 3D robustly optimized plans. Superior dose sparing of normal lung (lung D mean , P = 0.020) favoring 4D plans and comparable normal tissue sparing including esophagus, heart, and spinal cord for both 3D and 4D plans were observed. The calculation time for all patients included in this study was 11.4 ± 2.6 min. Conclusion A comprehensive plan robustness evaluation tool was successfully developed and benchmarked for plan robustness evaluation in the presence of interplay effect, setup and range uncertainties. The very high efficiency of this tool marks its clinical adaptation, highly practical and versatile nature, including possible real‐time intra‐fractional interplay effect evaluation as a potential application for future use.
Detecting spatial susceptibility to cardiac toxicity of radiation therapy for lung cancer