Back to Authors

Korte, Shawn

Mayo Clinic

Department of Radiation Oncology, Mayo Clinic, Phoenix, AZ, 85054, USA.

Citations 2

Beam angle comparison for distal esophageal carcinoma patients treated with intensity‐modulated proton therapy
Feng, Hongying , Rule, William G., Bhangoo, R.S. , Lara, Pedro, Patrick, Christopher L., Korte, Shawn M., Fatyga, M., Wong, William W. , Ashman, Jonathan B. , Bhangoo, Ronik S, Korte, Shawn, Fatyga, Mirek, Schild, Steven E. , Liu, Wei , Sio, Terence T. , Liu, Wei

Journal of Applied Clinical Medical Physics | October 15, 2020 | Volume: 21 | Issue: 11 | Pages: 141-152

10.1002/acm2.13049 Get It

Abstract Purpose To compare the dosimetric performances of intensity‐modulated proton therapy (IMPT) plans generated with two different beam angle configurations (the Right–Left oblique posterior beams and the Superior–Inferior oblique posterior beams) for the treatment of distal esophageal carcinoma in the presence of uncertainties and interplay effect. Methods and Materials Twenty patients’ IMPT plans were retrospectively selected, with 10 patients treated with the R‐L oblique posterior beams (Group R‐L) and the other 10 patients treated with the S‐I oblique posterior beams (Group S‐I). Patients in both groups were matched by their clinical target volumes (CTVs—high and low dose levels) and respiratory motion amplitudes. Dose‐volume‐histogram (DVH) indices were used to assess plan quality. DVH bandwidth was calculated to evaluate plan robustness. Interplay effect was quantified using four‐dimensional (4D) dynamic dose calculation with random respiratory starting phase of each fraction. Normal tissue complication probability (NTCP) for heart, liver, and lung was calculated, respectively, to estimate the clinical outcomes. Wilcoxon signed‐rank test was used for statistical comparison between the two groups. Results Compared with plans in Group R‐L, plans in Group S‐I resulted in significantly lower liver D mean and lung V 30Gy[RBE] with slightly higher but clinically acceptable spinal cord D max . Similar plan robustness was observed between the two groups. When interplay effect was considered, plans in Group S‐I performed statistically better for heart D mean and V 30Gy[RBE] , lung Dmean and V 5Gy[RBE] , and liver D mean , with slightly increased but clinically acceptable spinal cord D max . NTCP for liver was significantly better in Group S‐I. Conclusions IMPT plans in Group S‐I have better sparing of liver, heart, and lungs at the slight cost of spinal cord maximum dose protection, and are more interplay‐effect resilient compared to IMPT plans in Group R‐L. Our study supports the routine use of the S‐I oblique posterior beams for the treatments of distal esophageal carcinoma.
Dosimetric comparison of distal esophageal carcinoma plans for patients treated with small‐spot intensity‐modulated proton versus volumetric‐modulated arc therapies
Liu, Chenbin , Bhangoo, R.S. , Yu, Nathan Y. , Shan, Jie , Chiang, Jennifer S. , Ding, Julia, Rule, William G., Korte, Shawn M., Lara, Pedro, Ding, Xiaoning, Hu, Yanle , DeWees, T.A. , Ashman, Jonathan B. , Bhangoo, Ronik S, Ding, Julia X, Korte, Shawn, Bues, Martin , DeWees, Todd, DeWees, Todd A , Sio, Terence T. , Liu, Wei

Journal of Applied Clinical Medical Physics | May 21, 2019 | Volume: 20 | Issue: 7 | Pages: 15-27

10.1002/acm2.12623 Get It

BackgroundEsophageal carcinoma is the eighth most common cancer in the world. Volumetric‐modulated arc therapy (VMAT) is widely used to treat distal esophageal carcinoma due to high conformality to the target and good sparing of organs at risk (OAR). It is not clear if small‐spot intensity‐modulated proton therapy (IMPT) demonstrates a dosimetric advantage over VMAT. In this study, we compared dosimetric performance of VMAT and small‐spot IMPT for distal esophageal carcinoma in terms of plan quality, plan robustness, and interplay effects.Methods35 distal esophageal carcinoma patients were retrospectively reviewed; 19 patients received small‐spot IMPT and the remaining 16 of them received VMAT. Both plans were generated by delivering prescription doses to clinical target volumes (CTVs) on phase‐averaged 4D‐CT's. The dose‐volume‐histogram (DVH) band method was used to quantify plan robustness. Software was developed to evaluate interplay effects with randomized starting phases for each field per fraction. DVH indices were compared using Wilcoxon rank‐sum test. For fair comparison, all the treatment plans were normalized to have the same CTVhigh D95% in the nominal scenario relative to the prescription dose.ResultsIn the nominal scenario, small‐spot IMPT delivered statistically significantly lower liver Dmean and V30Gy[RBE], lung Dmean, heart Dmean compared with VMAT. CTVhigh dose homogeneity and protection of other OARs were comparable between the two treatments. In terms of plan robustness, the IMPT and VMAT plans were comparable for kidney V18Gy[RBE], liver V30Gy[RBE], stomach V45Gy[RBE], lung Dmean, V5Gy[RBE], and V20Gy[RBE], cord Dmax and , liver Dmean, heart V20Gy[RBE], and V30Gy[RBE], but IMPT was significantly worse for CTVhigh D95%, , and D5%‐D95%, CTVlow D95%, heart Dmean, and V40Gy[RBE], requiring careful and experienced adjustments during the planning process and robustness considerations. The small‐spot IMPT plans still met the standard clinical requirements after interplay effects were considered.ConclusionsSmall‐spot IMPT decreases doses to heart, liver, and total lung compared to VMAT as well as achieves clinically acceptable plan robustness. Our study supports the use of small‐spot IMPT for the treatment of distal esophageal carcinoma.