Study of linear energy transfer effect on rib fracture in breast cancer patients receiving pencil‐beam‐scanning proton therapy
Yang, Yunze, Afzal, Arslan, Mullikin, Trey C. , Gao, Robert W. , Shumway, Dean A. , Corbin, Kimberly S. , Liu, Wei , Mutter, Robert W. , Gergelis, Kimberly R. , Aziz, Khaled , Shen, Jiajian

Medical Physics | March 19, 2025 | Volume: 52 | Issue: 5 | Pages: 3428-3438

10.1002/mp.17745 Get It

Abstract Background In breast cancer patients treated with pencil‐beam scanning proton therapy (PBS), the increased linear energy transfer (LET) near the end of the proton range can affect nearby ribs. This may associate with a higher risk of rib fractures. Purpose To study the effect of LET on rib fracture in breast cancer patients treated with PBS using a novel tool of dose‐LET volume histogram (DLVH). Methods From a prospective registry of patients treated with post‐mastectomy proton therapy to the chest wall and regional lymph nodes for breast cancer between 2015 and 2020, we retrospectively identified rib fracture cases detected after completing treatment. Contemporaneously treated control patients who did not develop rib fracture were matched to patients 2:1 considering prescription dose, boost location, reconstruction status, laterality, chest wall thickness, and treatment year. The DLVH index, V (d, l), defined as volume( V ) of the structure with at least dose(d) and dose‐averaged LET (l) (LETd), was calculated. DLVH plots between the fracture and control group were compared. Conditional logistic regression (CLR) model was used to establish the relation of V (d, l) and the observed fracture at each combination of d and l . The p ‐value derived from CLR model shows the statistical difference between fracture patients and the matched control group. Using the 2D p ‐value map derived from CLR model, the DLVH features associated with the patient outcomes were extracted. Results Seven rib fracture patients were identified, and fourteen matched patients were selected for the control group. The median time from the completion of proton therapy to rib fracture diagnosis was 12 months (range 5–14 months). Two patients had grade 2 symptomatic rib fracture while the remaining 5 were grade 1 incidentally detected on imaging. The derived p ‐value map demonstrated larger V (0–36 Gy[RBE], 4.0–5.0 keV/µm) in patients experiencing fracture ( p < 0.1). For example, the p ‐value for V (30 Gy[RBE], 4.0 keV/um) was 0.069. Conclusion In breast cancer patients receiving PBS, a larger volume of chest wall receiving moderate dose and high LETd may result in an increased risk of rib fracture.
Deep‐learning based fast and accurate 3D CT deformable image registration in lung cancer
Ding, Yuzhen , Feng, Hongying , Yang, Yunze, Wong, William W. , Yu, Nathan Y. , Schild, Steven E. , Holmes, Jason , Liu, Zhengliang , Liu, David M. , Sio, Terence T. , Li, Baoxin , Liu, Wei

Medical Physics | June 8, 2023 | Volume: 50 | Issue: 11 | Pages: 6864-6880

10.1002/mp.16548 Get It

AbstractBackgroundDeformable Image Registration (DIR) is an essential technique required in many applications of radiation oncology. However, conventional DIR approaches typically take several minutes to register one pair of 3D CT images and the resulting deformable vector fields (DVFs) are only specific to the pair of images used, making it less appealing for clinical application.PurposeA deep‐learning‐based DIR method using CT images is proposed for lung cancer patients to address the common drawbacks of the conventional DIR approaches and in turn can accelerate the speed of related applications, such as contour propagation, dose deformation, adaptive radiotherapy (ART), etc.MethodsA deep neural network based on VoxelMorph was developed to generate DVFs using CT images collected from 114 lung cancer patients. Two models were trained with the weighted mean absolute error (wMAE) loss and structural similarity index matrix (SSIM) loss (optional) (i.e., the MAE model and the M+S model). In total, 192 pairs of initial CT (iCT) and verification CT (vCT) were included as a training dataset and the other independent 10 pairs of CTs were included as a testing dataset. The vCTs usually were taken 2 weeks after the iCTs. The synthetic CTs (sCTs) were generated by warping the vCTs according to the DVFs generated by the pre‐trained model. The image quality of the synthetic CTs was evaluated by measuring the similarity between the iCTs and the sCTs generated by the proposed methods and the conventional DIR approaches, respectively. Per‐voxel absolute CT‐number‐difference volume histogram (CDVH) and MAE were used as the evaluation metrics. The time to generate the sCTs was also recorded and compared quantitatively. Contours were propagated using the derived DVFs and evaluated with SSIM. Forward dose calculations were done on the sCTs and the corresponding iCTs. Dose volume histograms (DVHs) were generated based on dose distributions on both iCTs and sCTs generated by two models, respectively. The clinically relevant DVH indices were derived for comparison. The resulted dose distributions were also compared using 3D Gamma analysis with thresholds of 3 mm/3%/10% and 2 mm/2%/10%, respectively.ResultsThe two models (wMAE and M+S) achieved a speed of 263.7±163 / 265.8±190 ms and a MAE of 13.15±3.8 / 17.52±5.8 HU for the testing dataset, respectively. The average SSIM scores of 0.987±0.006 and 0.988±0.004 were achieved by the two proposed models, respectively. For both models, CDVH of a typical patient showed that less than 5% of the voxels had a per‐voxel absolute CT‐number‐difference larger than 55 HU. The dose distribution calculated based on a typical sCT showed differences of ≤2cGy[RBE] for clinical target volume (CTV) D95 and D5, within ±0.06% for total lung V5, ≤1.5cGy[RBE] for heart and esophagus Dmean, and ≤6cGy[RBE] for cord Dmax compared to the dose distribution calculated based on the iCT. The good average 3D Gamma passing rates (> 96% for 3 mm/3%/10% and > 94% for 2 mm/2%/10%, respectively) were also observed.ConclusionA deep neural network‐based DIR approach was proposed and has been shown to be reasonably accurate and efficient to register the initial CTs and verification CTs in lung cancer.
Technical note: Investigation of dose and LETd effect to rectum and bladder by using non‐straight laterals in prostate cancer receiving proton therapy
Yang, Yunze, Rwigema, Jean‐Claude M. , Vargas, Carlos , Yu, Nathan Y. , Keole, Sameer R., Wong, William W. , Shen, Jiajian , Schild, Steven E. , Shen, Jiajian , Bues, Martin , Liu, Wei

Medical Physics | October 8, 2022 | Volume: 49 | Issue: 12 | Pages: 7428-7437

10.1002/mp.16008 Get It

AbstractBackgroundParallel‐opposed lateral beams are the conventional beam arrangements in proton therapy for prostate cancer. However, when considering linear energy transfer (LET) and RBE effects, alternative beam arrangements should be investigated.PurposeTo investigate the dose and dose averaged LET (LETd) impact of using new beam arrangements rotating beams 5°–15° posteriorly to the laterals in prostate cancer treated with pencil‐beam‐scanning (PBS) proton therapy.MethodsTwenty patients with localized prostate cancer were included in this study. Four proton treatment plans for each patient were generated utilizing 0°, 5°, 10°, and 15° posterior oblique beam pairs relative to parallel‐opposed lateral beams. Dose‐volume histograms (DVHs) from posterior oblique beams were analyzed. Dose‐LETd‐volume histogram (DLVH) was employed to study the difference in dose and LETd with each beam arrangement. DLVH indices, , defined as the cumulative absolute volume that has a dose of at least d (Gy[RBE]) and a LETd of at least l (keV/µm), were calculated for both the rectum and bladder to the whole group of patients and two‐sub groups with and without hydrogel spacer. These metrics were tested using Wilcoxon signed‐rank test.ResultsRotating beam angles from laterals to slightly posterior by 5°–15° reduced high LETd volumes while it increased the dose volume in the rectum and increased LETd in bladders. Beam angles rotated five degrees posteriorly from laterals (i.e., gantry in 95° and 265°) are proposed since they achieved the optimal balance of better LETd sparing and minimal dose increase in the rectum. A reduction of V(50 Gy[RBE], 2.6 keV/µm) from 7.41 to 3.96 cc (p < 0.01), and a slight increase of V(50 Gy[RBE], 0 keV/µm) from 20.1 to 21.6 cc (p < 0.01) were observed for the group without hydrogel spacer. The LETd sparing was less effective for the group with hydrogel spacer, which achieved the reduction of V(50 Gy[RBE], 2.6 keV/µm) from 4.28 to 2.10 cc (p < 0.01).ConclusionsPosterior oblique angle plans improved LETd sparing of the rectum while sacrificing LETd sparing in the bladder in the treatment of prostate cancer with PBS. Beam angle modification from laterals to slightly posterior may be a strategy to redistribute LETd and perhaps reduce rectal toxicity risks in prostate cancer patients treated with PBS. However, the effect is reduced for patients with hydrogel spacer.
Exploratory study of seed spots analysis to characterize dose and linear‐energy‐transfer effect in adverse event initialization of pencil‐beam‐scanning proton therapy
Yang, Yunze, Patel, Samir H. , Bridhikitti, Jidapa , Wong, William W. , Halyard, Michele Y. , McGee, L.A. , Rwigema, Jean‐Claude M. , Vora, Sujay A., Liu, Tianming , Fatyga, M., Foote, Robert L. , McGee, Lisa A, Schild, Steven E. , Bues, Martin , Fatyga, Mirek, Liu, Wei

Medical Physics | July 12, 2022 | Volume: 49 | Issue: 9 | Pages: 6237-6252

10.1002/mp.15859 Get It

AbstractBackgroundBoth dose and linear energy transfer (LET) could play a substantial role in adverse event (AE) initialization of cancer patients treated with pencil‐beam‐scanning (PBS) proton therapy. However, not all the voxels within the AE regions are directly induced from the dose and LET effect. It is important to study the synergistic effect of dose and LET in AE initialization by only including a subset of voxels that are dosimetrically important.PurposeTo perform exploratory investigation of the dose and LET effects upon AE initialization in PBS using seed spots analysis.MethodsA total of 113 head‐and‐neck (H&N) cancer patients receiving curative PBS were included. Among them, 20 patients experienced unanticipated CTCAEv4.0 grade ≥3 AEs (AE group) and 93 patients did not (control group). Within the AE group, 13 AE patients were included in the seed spot analysis to derive the descriptive features of AE initialization and the remaining 7 mandible osteoradionecrosis patients and 93 control patients were used to derive the feature‐based volume constraint of mandible osteoradionecrosis. The AE regions were contoured and the corresponding dose–LET volume histograms of AE regions were generated for all patients in the AE group. We selected high LET voxels (the highest 5% of each dose bin) with a range of moderate‐to‐high dose (≥∼40‐Gy relative biological effectiveness) as critical voxels. Critical voxels that were contiguous with each other were grouped into clusters. Each cluster was considered a potential independent seed spot for AE initialization. Seed spots were displayed in a 2D dose–LET plane based on their mean dose and LET to derive the descriptive features of AE initialization. A volume constraint of mandible osteoradionecrosis was then established based on the extracted features using a receiver operating characteristic curve.ResultsThe product of dose and LET (xBD) was found to be a descriptive feature of seed spots leading to AE initialization in this preliminary study. The derived xBD volume constraint for mandible osteoradionecrosis showed good performance with an area under curve of 0.87 (sensitivity of 0.714 and specificity of 0.807 in the leave‐one‐out cross‐validation) for the very limited patient data included in this study.ConclusionOur exploratory study showed that both dose and LET were observed to be important in AE initializations. The derived xBD volume constraint could predict mandible osteoradionecrosis reasonably well in the very limited H&N cancer patient data treated with PBS included in this study.
Intensity‐modulated proton therapy (IMPT) interplay effect evaluation of asymmetric breathing with simultaneous uncertainty considerations in patients with non‐small cell lung cancer
Shan, Jie , Yang, Yunze, Daniels, T.B., Wong, William W. , Fatyga, M., Schild, Steven E. , Daniels, Thomas B, Fatyga, Mirek, Bues, Martin , Sio, Terence T. , Liu, Wei

Medical Physics | September 22, 2020 | Volume: 47 | Issue: 11 | Pages: 5428-5440

10.1002/mp.14491 Get It

Purpose Intensity‐modulated proton therapy (IMPT) is sensitive to uncertainties from patient setup and proton beam range, as well as interplay effect. In addition, respiratory motion may vary from cycle to cycle, and also from day to day. These uncertainties can severely degrade the original plan quality and potentially affect patient’s outcome. In this work, we developed a new tool to comprehensively consider the impact of all these uncertainties and provide plan robustness evaluation under them. Methods We developed a comprehensive plan robustness evaluation tool that considered both uncertainties from patient setup and proton beam range, as well as respiratory motion simultaneously. To mimic patients' respiratory motion, the time spent in each phase was randomly sampled based on patient‐specific breathing pattern parameters as acquired during the four‐dimensional (4D)‐computed tomography (CT) simulation. Spots were then assigned to one specific phase according to the temporal relationship between spot delivery sequence and patients’ respiratory motion. Dose in each phase was calculated by summing contributions from all the spots delivered in that phase. The final 4D dynamic dose was obtained by deforming all doses in each phase to the maximum exhalation phase. Three hundred (300) scenarios (10 different breathing patterns with 30 different setup and range uncertainty scenario combinations) were calculated for each plan. The dose‐volume histograms (DVHs) band method was used to assess plan robustness. Benchmarking the tool as an application’s example, we compared plan robustness under both three‐dimensional (3D) and 4D robustly optimized IMPT plans for 10 nonrandomly selected patients with non‐small cell lung cancer. Results The developed comprehensive plan robustness tool had been successfully applied to compare the plan robustness between 3D and 4D robustly optimized IMPT plans for 10 lung cancer patients. In the presence of interplay effect with uncertainties considered simultaneously, 4D robustly optimized plans provided significantly better CTV coverage (D 95% , P = 0.002), CTV homogeneity (D 5% ‐D 95% , P = 0.002) with less target hot spots (D 5% , P = 0.002), and target coverage robustness (CTV D 95% bandwidth, P = 0.004) compared to 3D robustly optimized plans. Superior dose sparing of normal lung (lung D mean , P = 0.020) favoring 4D plans and comparable normal tissue sparing including esophagus, heart, and spinal cord for both 3D and 4D plans were observed. The calculation time for all patients included in this study was 11.4 ± 2.6 min. Conclusion A comprehensive plan robustness evaluation tool was successfully developed and benchmarked for plan robustness evaluation in the presence of interplay effect, setup and range uncertainties. The very high efficiency of this tool marks its clinical adaptation, highly practical and versatile nature, including possible real‐time intra‐fractional interplay effect evaluation as a potential application for future use.