Back to Authors

Li, Baoxin

0000-0002-9294-4572

Mayo Clinic

Arizona State University

Citations 5

Using Large-scale Contrastive Language-Image Pre-training to Maximize Brain MRI-Based Headache Classification (P4-12.007)
Rafsani, Fazle , Sheth, Devam, Che, Yiming , Shah, Jay , Nikolva, Simona, Sheth, Devam, Siddiquee, Md Mahfuzur Rahman , Chong, Catherine D. , Dumkrieger, Gina , Li, Baoxin , Wu, Teresa , Schwedt, Todd J.

Neurology | April 7, 2025 | Volume: 104 | Issue: 7_Supplement_1 | Pages: No page available

10.1212/wnl.0000000000210540 Get It

Applying Generative Adversarial Network on Structural Brain MRI for Unsupervised Classification of Headache (P5-12.003)
Shah, Jay , Siddiquee, Md Mahfuzur Rahman , Schwedt, Todd J. , Chong, Catherine D. , Li, Baoxin , Wu, Teresa

Neurology | April 9, 2024 | Volume: 102 | Issue: 7_supplement_1 | Pages: No page available

10.1212/wnl.0000000000204957 Get It

Prediction of Headache Improvement Using Multimodal Machine Learning in Patients with Acute Post-traumatic Headache (P5-12.002)
Joshi, Amogh , Shah, Jay , Joshi, Amogh, Siddiquee, Md Mahfuzur Rahman , Schwedt, Todd J. , Chong, Catherine D. , Li, Baoxin , Wu, Teresa

Neurology | April 9, 2024 | Volume: 102 | Issue: 7_supplement_1 | Pages: No page available

10.1212/wnl.0000000000205109 Get It

Deep‐learning based fast and accurate 3D CT deformable image registration in lung cancer
Ding, Yuzhen , Feng, Hongying , Yang, Yunze, Wong, William W. , Yu, Nathan Y. , Schild, Steven E. , Holmes, Jason , Liu, Zhengliang , Liu, David M. , Sio, Terence T. , Li, Baoxin , Liu, Wei

Medical Physics | June 8, 2023 | Volume: 50 | Issue: 11 | Pages: 6864-6880

10.1002/mp.16548 Get It

AbstractBackgroundDeformable Image Registration (DIR) is an essential technique required in many applications of radiation oncology. However, conventional DIR approaches typically take several minutes to register one pair of 3D CT images and the resulting deformable vector fields (DVFs) are only specific to the pair of images used, making it less appealing for clinical application.PurposeA deep‐learning‐based DIR method using CT images is proposed for lung cancer patients to address the common drawbacks of the conventional DIR approaches and in turn can accelerate the speed of related applications, such as contour propagation, dose deformation, adaptive radiotherapy (ART), etc.MethodsA deep neural network based on VoxelMorph was developed to generate DVFs using CT images collected from 114 lung cancer patients. Two models were trained with the weighted mean absolute error (wMAE) loss and structural similarity index matrix (SSIM) loss (optional) (i.e., the MAE model and the M+S model). In total, 192 pairs of initial CT (iCT) and verification CT (vCT) were included as a training dataset and the other independent 10 pairs of CTs were included as a testing dataset. The vCTs usually were taken 2 weeks after the iCTs. The synthetic CTs (sCTs) were generated by warping the vCTs according to the DVFs generated by the pre‐trained model. The image quality of the synthetic CTs was evaluated by measuring the similarity between the iCTs and the sCTs generated by the proposed methods and the conventional DIR approaches, respectively. Per‐voxel absolute CT‐number‐difference volume histogram (CDVH) and MAE were used as the evaluation metrics. The time to generate the sCTs was also recorded and compared quantitatively. Contours were propagated using the derived DVFs and evaluated with SSIM. Forward dose calculations were done on the sCTs and the corresponding iCTs. Dose volume histograms (DVHs) were generated based on dose distributions on both iCTs and sCTs generated by two models, respectively. The clinically relevant DVH indices were derived for comparison. The resulted dose distributions were also compared using 3D Gamma analysis with thresholds of 3 mm/3%/10% and 2 mm/2%/10%, respectively.ResultsThe two models (wMAE and M+S) achieved a speed of 263.7±163 / 265.8±190 ms and a MAE of 13.15±3.8 / 17.52±5.8 HU for the testing dataset, respectively. The average SSIM scores of 0.987±0.006 and 0.988±0.004 were achieved by the two proposed models, respectively. For both models, CDVH of a typical patient showed that less than 5% of the voxels had a per‐voxel absolute CT‐number‐difference larger than 55 HU. The dose distribution calculated based on a typical sCT showed differences of ≤2cGy[RBE] for clinical target volume (CTV) D95 and D5, within ±0.06% for total lung V5, ≤1.5cGy[RBE] for heart and esophagus Dmean, and ≤6cGy[RBE] for cord Dmax compared to the dose distribution calculated based on the iCT. The good average 3D Gamma passing rates (> 96% for 3 mm/3%/10% and > 94% for 2 mm/2%/10%, respectively) were also observed.ConclusionA deep neural network‐based DIR approach was proposed and has been shown to be reasonably accurate and efficient to register the initial CTs and verification CTs in lung cancer.
Deep residual inception encoder‐decoder network for amyloid PET harmonization
Shah, Jay , Gao, Fei , Ghisays, Valentina , Luo, Ji , Chen, Yinghua , Lee, Wendy , Zhou, Yuxiang, Reiman, Eric M. , Li, Baoxin , Zhou, Yuxiang , Benzinger, Tammie L.S. , Chen, Kewei , Su, Yi , Wu, Teresa

Alzheimer's & Dementia | February 10, 2022 | Volume: 18 | Issue: 12 | Pages: 2448-2457

10.1002/alz.12564 Get It

AbstractIntroductionMultiple positron emission tomography (PET) tracers are available for amyloid imaging, posing a significant challenge to consensus interpretation and quantitative analysis. We accordingly developed and validated a deep learning model as a harmonization strategy.MethodA Residual Inception Encoder‐Decoder Neural Network was developed to harmonize images between amyloid PET image pairs made with Pittsburgh Compound‐B and florbetapir tracers. The model was trained using a dataset with 92 subjects with 10‐fold cross validation and its generalizability was further examined using an independent external dataset of 46 subjects.ResultsSignificantly stronger between‐tracer correlations (P < .001) were observed after harmonization for both global amyloid burden indices and voxel‐wise measurements in the training cohort and the external testing cohort.DiscussionWe proposed and validated a novel encoder‐decoder based deep model to harmonize amyloid PET imaging data from different tracers. Further investigation is ongoing to improve the model and apply to additional tracers.