Back to Authors

Liu, Zhengliang

https://orcid.org/0000-0001-7061-6714

Mayo Clinic

University of Georgia

Citations 7

Noisy probing dose facilitated dose prediction for pencil beam scanning proton therapy: Physics enhances generalizability
Zhang, Lian , Zhang, Xiao, Li, Mingzhu, Vargas, Carlos , Keole, Sameer R., Stützer, Kristin , Liu, Tianming , Wong, William W. , Vora, Sujay A., Feng, Hongying , Holmes, Jason , Zhang, Xiao, Liu, Zhengliang , Li, Mingzhu, Sio, Terence T. , Li, Sheng , Shen, Jiajian , Liu, Wei

Medical Physics | May 27, 2026 | Volume: 53 | Issue: 5 | Pages: No page available

10.1002/mp.70509 Get It

Abstract Background Accurate and efficient dose calculation is essential for online adaptive planning in proton therapy. Deep learning (DL) has shown promising dose prediction results for pencil beam scanning proton therapy (PBSPT) in recent years, but existing DL‐based dose prediction methods still suffer from limited generalizability and an inability to effectively handle outlier clinical cases. This may lead to inaccurate dose delivery to targets or excessive irradiation to organs at risk (OARs), thereby compromising the safety and efficacy of online adaptive proton therapy. Purpose To design a physics‐aware and generalizable AI‐based PBSPT dose prediction method that incorporates underlying physics to enhance generalizability, particularly in handling outlier clinical cases. Methods This study analyzed PBSPT plans of 103 prostate (93 for training and 10 for testing) and 78 lung cancer patients (68 for training and 10 for testing) from our institution, with each case comprising CT images and structure sets. Using the doses generated by our Monte Carlo‐based dose engine as the reference standard, we compared three methods: the region of interest (ROI)‐based method, the beam mask and sliding window method, and the proposed noisy probing dose method, which rapidly generates a low‐statistics dose via uniformly weighted spots on an expanded spot‐placement target volume without optimization. To evaluate the generalizability of these methods to rare treatment planning scenarios, 12 cases with uncommon beam angles or prescription doses were used to assess their performance, which was evaluated using dose‐volume histogram (DVH) indices, 3D Gamma passing rates (3%/2 mm/10%), and Dice coefficients for dose agreement, while prediction times were measured to gauge model efficiency. Results The proposed noisy probing dose method consistently outperformed the ROI‐based and beam mask baselines across all evaluated metrics, with more accurate dose agreement and superior generalizability. For DVH indices, the noisy probing dose method achieved the smallest deviation in clinical target volume (CTV) dose coverage: in prostate cancer, CTV D98 deviation was reduced by 45% (from 0.53 ± 0.22 Gy [RBE] for ROI‐based) and 29% (from 0.41 ± 0.28 Gy [RBE] for beam mask) to 0.29 ± 0.06 Gy [RBE]; in lung cancer, similar improvements were observed, with CTV D98 deviations reduced to 0.34 ± 0.12 Gy [RBE]. The 3D Gamma passing rates improved to 99.65% ± 1.15% for prostate targets and 97.04% ± 1.17% for lung targets. The dice coefficients of the 90% iso‐dose lines were also the highest with the noisy probing dose method (prostate: 0.983 ± 0.005; lung: 0.967 ± 0.01). For the 12 outlier cases, the noisy probing dose method maintained superior generalizability, yielding higher 3D Gamma passing rates (prostate targets: 96.79% ± 0.83%, OARs: 94.29% ± 1.01%; lung targets: 93.38% ± 1.34%, OARs: 93.95% ± 1.32%), demonstrating robust generalizability to rare clinical scenarios. The dose predictions for all testing cases were completed within 0.3 seconds. Conclusions A novel noisy probing dose method was proposed for PBSPT dose prediction in prostate and lung cancer patients. By embedding more proton‐specific physics, this method demonstrated an improvement in the generalizability of dose prediction.
Exploring the Trade-Offs: Unified Large Language Models vs Local Fine-Tuned Models for Highly-Specific Radiology NLI Task
Wu, Zihao , Zhang, Lu , Cao, Chao , Liu, Zhengliang , Zhao, Lin , Li, Yiwei , Dai, Haixing , Ma, Chong , Li, Gang , Liu, Tianming , Wu, Zihao , Zhang, Lu , Yu, Xiaowei , Liu, Wei , Li, Quanzheng , Shen, Dinggang G. , Li, Xiang , Zhu, Dajiang , Liu, Tianming

IEEE Transactions on Big Data | February 13, 2025 | Volume: 11 | Issue: 3 | Pages: 1027-1041

10.1109/tbdata.2025.3536928 Get It

AugGPT: Leveraging ChatGPT for Text Data Augmentation
Dai, Haixing , Liu, Zhengliang , Liao, Wenxiong , Huang, Xiaoke , Wu, Zihao , Zhao, Lin , Xu, Shaochen , Zeng, Fang , Liu, Wei , Liu, Ninghao , Shen, Dinggang, Liu, Tianming , Li, Xiang , Liu, Wei , Cao, Yihan , Li, Sheng , Zhu, Dajiang , Cai, Hongmin , Sun, Lichao , Li, Quanzheng , Shen, Dinggang G. , Li, Xiang

IEEE Transactions on Big Data | January 30, 2025 | Volume: 11 | Issue: 3 | Pages: 907-918

10.1109/tbdata.2025.3536934 Get It

Artificial General Intelligence for Medical Imaging Analysis
Li, Xiang , Zhao, Lin , Zhang, Lu , Wu, Zihao , Liu, Zhengliang , Jiang, Hanqi , Cao, Chao , Xu, Shaochen , Li, Yiwei , Dai, Haixing , Liu, Jun , Liu, Tianming , Yuan, Yixuan , Li, Gang , Zhu, Dajiang , Yan, Pingkun , Li, Quanzheng , Liu, Wei , Shen, Dinggang G.

IEEE Reviews in Biomedical Engineering | November 7, 2024 | Volume: 18 | Issue: No issue available | Pages: 113-129

10.1109/rbme.2024.3493775 Get It

Beam mask and sliding window‐facilitated deep learning‐based accurate and efficient dose prediction for pencil beam scanning proton therapy
Zhang, Lian , Vora, Sujay A., Vargas, Carlos , Yu, Nathan Y. , Keole, Sameer R., Liu, Tianming , Shen, Jiajian , Wong, William W. , Holmes, Jason M, Schild, Steven E. , Shen, Jiajian , Holmes, Jason , Liu, Zhengliang , Sio, Terence T. , Bues, Martin , Li, Sheng , Liu, Wei

Medical Physics | September 25, 2023 | Volume: 51 | Issue: 2 | Pages: 1484-1498

10.1002/mp.16758 Get It

AbstractBackgroundAccurate and efficient dose calculation is essential for on‐line adaptive planning in proton therapy. Deep learning (DL) has shown promising dose prediction results in photon therapy. However, there is a scarcity of DL‐based dose prediction methods specifically designed for proton therapy. Successful dose prediction method for proton therapy should account for more challenging dose prediction problems in pencil beam scanning proton therapy (PBSPT) due to its sensitivity to heterogeneities.PurposeTo develop a DL‐based PBSPT dose prediction workflow with high accuracy and balanced complexity to support on‐line adaptive proton therapy clinical decision and subsequent replanning.MethodsPBSPT plans of 103 prostate cancer patients (93 for training and the other 10 for independent testing) and 83 lung cancer patients (73 for training and the other 10 for independent testing) previously treated at our institution were included in the study, each with computed tomography scans (CTs), structure sets, and plan doses calculated by the in‐house developed Monte‐Carlo dose engine (considered as the ground truth in the model training and testing). For the ablation study, we designed three experiments corresponding to the following three methods: (1) Experiment 1, the conventional region of interest (ROI) (composed of targets and organs‐at‐risk [OARs]) method. (2) Experiment 2, the beam mask (generated by raytracing of proton beams) method to improve proton dose prediction. (3) Experiment 3, the sliding window method for the model to focus on local details to further improve proton dose prediction. A fully connected 3D‐Unet was adopted as the backbone. Dose volume histogram (DVH) indices, 3D Gamma passing rates with a criterion of 3%/3 mm/10%, and dice coefficients for the structures enclosed by the iso‐dose lines between the predicted and the ground truth doses were used as the evaluation metrics. The calculation time for each proton dose prediction was recorded to evaluate the method's efficiency.ResultsCompared to the conventional ROI method, the beam mask method improved the agreement of DVH indices for both targets and OARs and the sliding window method further improved the agreement of the DVH indices (for lung cancer, CTV D98 absolute deviation: 0.74 ± 0.18 vs. 0.57 ± 0.21 vs. 0.54 ± 0.15 Gy[RBE], ROI vs. beam mask vs. sliding window methods, respectively). For the 3D Gamma passing rates in the target, OARs, and BODY (outside target and OARs), the beam mask method improved the passing rates in these regions and the sliding window method further improved them (for prostate cancer, targets: 96.93% ± 0.53% vs. 98.88% ± 0.49% vs. 99.97% ± 0.07%, BODY: 86.88% ± 0.74% vs. 93.21% ± 0.56% vs. 95.17% ± 0.59%). A similar trend was also observed for the dice coefficients. This trend was especially remarkable for relatively low prescription isodose lines (for lung cancer, 10% isodose line dice: 0.871 ± 0.027 vs. 0.911 ± 0.023 vs. 0.927 ± 0.017). The dose predictions for all the testing cases were completed within 0.25 s.ConclusionsAn accurate and efficient deep learning‐augmented proton dose prediction framework has been developed for PBSPT, which can predict accurate dose distributions not only inside but also outside ROI efficiently. The framework can potentially further reduce the initial planning and adaptive replanning workload in PBSPT.
Deep‐learning based fast and accurate 3D CT deformable image registration in lung cancer
Ding, Yuzhen , Feng, Hongying , Yang, Yunze, Wong, William W. , Yu, Nathan Y. , Schild, Steven E. , Holmes, Jason , Liu, Zhengliang , Liu, David M. , Sio, Terence T. , Li, Baoxin , Liu, Wei

Medical Physics | June 8, 2023 | Volume: 50 | Issue: 11 | Pages: 6864-6880

10.1002/mp.16548 Get It

AbstractBackgroundDeformable Image Registration (DIR) is an essential technique required in many applications of radiation oncology. However, conventional DIR approaches typically take several minutes to register one pair of 3D CT images and the resulting deformable vector fields (DVFs) are only specific to the pair of images used, making it less appealing for clinical application.PurposeA deep‐learning‐based DIR method using CT images is proposed for lung cancer patients to address the common drawbacks of the conventional DIR approaches and in turn can accelerate the speed of related applications, such as contour propagation, dose deformation, adaptive radiotherapy (ART), etc.MethodsA deep neural network based on VoxelMorph was developed to generate DVFs using CT images collected from 114 lung cancer patients. Two models were trained with the weighted mean absolute error (wMAE) loss and structural similarity index matrix (SSIM) loss (optional) (i.e., the MAE model and the M+S model). In total, 192 pairs of initial CT (iCT) and verification CT (vCT) were included as a training dataset and the other independent 10 pairs of CTs were included as a testing dataset. The vCTs usually were taken 2 weeks after the iCTs. The synthetic CTs (sCTs) were generated by warping the vCTs according to the DVFs generated by the pre‐trained model. The image quality of the synthetic CTs was evaluated by measuring the similarity between the iCTs and the sCTs generated by the proposed methods and the conventional DIR approaches, respectively. Per‐voxel absolute CT‐number‐difference volume histogram (CDVH) and MAE were used as the evaluation metrics. The time to generate the sCTs was also recorded and compared quantitatively. Contours were propagated using the derived DVFs and evaluated with SSIM. Forward dose calculations were done on the sCTs and the corresponding iCTs. Dose volume histograms (DVHs) were generated based on dose distributions on both iCTs and sCTs generated by two models, respectively. The clinically relevant DVH indices were derived for comparison. The resulted dose distributions were also compared using 3D Gamma analysis with thresholds of 3 mm/3%/10% and 2 mm/2%/10%, respectively.ResultsThe two models (wMAE and M+S) achieved a speed of 263.7±163 / 265.8±190 ms and a MAE of 13.15±3.8 / 17.52±5.8 HU for the testing dataset, respectively. The average SSIM scores of 0.987±0.006 and 0.988±0.004 were achieved by the two proposed models, respectively. For both models, CDVH of a typical patient showed that less than 5% of the voxels had a per‐voxel absolute CT‐number‐difference larger than 55 HU. The dose distribution calculated based on a typical sCT showed differences of ≤2cGy[RBE] for clinical target volume (CTV) D95 and D5, within ±0.06% for total lung V5, ≤1.5cGy[RBE] for heart and esophagus Dmean, and ≤6cGy[RBE] for cord Dmax compared to the dose distribution calculated based on the iCT. The good average 3D Gamma passing rates (> 96% for 3 mm/3%/10% and > 94% for 2 mm/2%/10%, respectively) were also observed.ConclusionA deep neural network‐based DIR approach was proposed and has been shown to be reasonably accurate and efficient to register the initial CTs and verification CTs in lung cancer.