Objective: Evaluating the feasibility of closed-loop insulin delivery with a zone model predictive control (zone-MPC) algorithm designed for pregnancy complicated by type 1 diabetes (T1D). Research Design and Methods: Pregnant women with T1D from 14 to 32 weeks gestation already using continuous glucose monitor (CGM) augmented pump therapy were enrolled in a 2-day multicenter supervised outpatient study evaluating pregnancy-specific zone-MPC based closed-loop control (CLC) with the interoperable artificial pancreas system (iAPS) running on an unlocked smartphone. Meals and activities were unrestricted. The primary outcome was the CGM percentage of time between 63 and 140 mg/dL compared with participants' 1-week run-in period. Early (2-h) postprandial glucose control was also evaluated. Results: Eleven participants completed the study (age: 30.6 ± 4.1 years; gestational age: 20.7 ± 3.5 weeks; weight: 76.5 ± 15.3 kg; hemoglobin A1c: 5.6% ± 0.5% at enrollment). No serious adverse events occurred. Compared with the 1-week run-in, there was an increased percentage of time in 63–140 mg/dL during supervised CLC (CLC: 81.5%, run-in: 64%, P = 0.007) with less time >140 mg/dL (CLC: 16.5%, run-in: 30.8%, P = 0.029) and time <63 mg/dL (CLC: 2.0%, run-in:5.2%, P = 0.039). There was also less time <54 mg/dL (CLC: 0.7%, run-in:1.6%, P = 0.030) and >180 mg/dL (CLC: 4.9%, run-in: 13.1%, P = 0.032). Overnight glucose control was comparable, except for less time >250 mg/dL (CLC: 0%, run-in:3.9%, P = 0.030) and lower glucose standard deviation (CLC: 23.8 mg/dL, run-in:42.8 mg/dL, P = 0.007) during CLC. Conclusion: In this pilot study, use of the pregnancy-specific zone-MPC was feasible in pregnant women with T1D. Although the duration of our study was short and the number of participants was small, our findings add to the limited data available on the use of CLC systems during pregnancy (NCT04492566).
Insulin Delivery and Glucose Variability Throughout the Menstrual Cycle on Closed Loop Control for Women with Type 1 Diabetes
Objective: To analyze insulin delivery and glycemic metrics throughout the menstrual cycle for women with type 1 diabetes using closed loop control (CLC) insulin delivery. Methods: Menstruating women using a CLC system in a clinical trial were invited to record their menstrual cycles through a cycle-tracking application. Sixteen participants provided data for this secondary analysis over three or more complete cycles. Insulin delivery and continuous glucose monitoring (CGM) data were analyzed in relation to reported cycle phases. Results: Insulin delivery and CGM metrics remained consistent during cycle phases. Intraparticipant variability of CGM metrics and weight-based insulin delivery did not change through cycle phases. Conclusions: For this sample of menstruating women with type 1 diabetes using a CLC system, insulin delivery and glycemic metrics remained stable throughout menstrual cycle phases. Additional studies in this population are needed, particularly among women who report variable glycemic control during their cycles. Trial Registration: NCT03591354.
Outpatient Randomized Crossover Automated Insulin Delivery Versus Conventional Therapy with Induced Stress Challenges
Background: Automated insulin delivery (AID) systems have not been evaluated in the context of psychological and pharmacological stress in type 1 diabetes. Our objective was to determine glycemic control and insulin use with Zone Model Predictive Control (zone-MPC) AID system enhanced for states of persistent hyperglycemia versus sensor-augmented pump (SAP) during outpatient use, including in-clinic induced stress. Materials and Methods: Randomized, crossover, 2-week trial of zone-MPC AID versus SAP in 14 adults with type 1 diabetes. In each arm, each participant was studied in-clinic with psychological stress induction (Trier Social Stress Test [TSST] and Socially Evaluated Cold Pressor Test [SECPT]), followed by pharmacological stress induction with oral hydrocortisone (total four sessions per participant). The main outcomes were 2-week continuous glucose monitor percent time in range (TIR) 70–180 mg/dL, and glucose and insulin outcomes during and overnight following stress induction. Results: During psychological stress, AID decreased glycemic variability percentage by 13.4% ( P = 0.009). During pharmacological stress, including the following overnight, there were no differences in glucose outcomes and total insulin between AID and physician-assisted SAP. However, with AID total user-requested insulin was lower by 6.9 U ( P = 0.01) for pharmacological stress. Stress induction was validated by changes in heart rate and salivary cortisol levels. During the 2-week AID use, TIR was 74.4% (vs. SAP 63.1%, P = 0.001) and overnight TIR was 78.3% (vs. SAP 63.1%, P = 0.004). There were no adverse events. Conclusions: Zone-MPC AID can reduce glycemic variability and the need for user-requested insulin during pharmacological stress and can improve overall glycemic outcomes. Clinical Trial Identifier NCT04142229.
Longitudinal Observation of Insulin Use and Glucose Sensor Metrics in Pregnant Women with Type 1 Diabetes Using Continuous Glucose Monitors and Insulin Pumps: The LOIS-P Study
Background: Suboptimal glycemic control is associated with maternal and neonatal morbidity and mortality in pregnancy complicated by type 1 diabetes (T1D). Prospective analysis of continuous glucose monitoring (CGM) metrics, insulin pump settings, and insulin delivery can better characterize the changes in glycemic levels and insulin use throughout pregnancy with T1D. Materials and Methods: Prescribed parameters, insulin delivery, carbohydrate intake, and CGM data for 25 pregnant women with T1D from three U.S. sites were collected. Participants enrolled before 17 weeks gestation and used personal insulin pumps and study CGM. Mean daily total, basal, and bolus insulin doses (units/kg), CGM time in range (TIR: 63–140 mg/dL), and pump-entered carbohydrates were analyzed for every 2-week gestational interval. Linear mixed-effects regression models were used to evaluate changes across gestational ages compared to 12–14 weeks. Results: Basal insulin was higher during weeks 6–12 and 24–40. Daily bolus and total insulin were higher during weeks 20–40. Pump parameters were adjusted to intensify insulin therapy from 22 weeks onward. Average TIR across pregnancy was 59% ± 14%. Between 18 and 30 weeks, TIR was significantly lower, and time above range was significantly higher compared to the reference biweek. Time below target was lower between 22 and 34 weeks. Seven participants achieved >70% recommended TIR for pregnancy. Participants with maternal complications or infant neonatal intensive care unit admissions had lower TIR. Conclusion: While insulin dosing changed significantly with advancing gestation, most participants did not achieve >70% TIR. Customized anticipatory pump setting adjustments and automated systems aimed toward the designated TIR are needed to improve outcomes for this population. NCT03761615
Clinical Experience of Continuous Glucose Monitoring in Pregnancy
Background: Closed-loop control (CLC) has been shown to improve glucose time in range and other glucose metrics; however, randomized trials >3 months comparing CLC with sensor-augmented pump (SAP) therapy are limited. We recently reported glucose control outcomes from the 6-month international Diabetes Closed-Loop (iDCL) trial; we now report patient-reported outcomes (PROs) in this iDCL trial. Methods: Participants were randomized 2:1 to CLC ( N = 112) versus SAP ( N = 56) and completed questionnaires, including Hypoglycemia Fear Survey, Diabetes Distress Scale (DDS), Hypoglycemia Awareness, Hypoglycemia Confidence, Hyperglycemia Avoidance, and Positive Expectancies of CLC (INSPIRE) at baseline, 3, and 6 months. CLC participants also completed Diabetes Technology Expectations and Acceptance and System Usability Scale (SUS). Results: The Hypoglycemia Fear Survey Behavior subscale improved significantly after 6 months of CLC compared with SAP. DDS did not differ except for powerless subscale scores, which worsened at 3 months in SAP. Whereas Hypoglycemia Awareness and Hyperglycemia Avoidance did not differ between groups, CLC participants showed a tendency toward improved confidence in managing hypoglycemia. The INSPIRE questionnaire showed favorable scores in the CLC group for teens and parents, with a similar trend for adults. At baseline and 6 months, CLC participants had high positive expectations for the device with Diabetes Technology Acceptance and SUS showing high benefit and low burden scores. Conclusion: CLC improved some PROs compared with SAP. Participants reported high benefit and low burden with CLC. Clinical Trial Identifier: NCT03563313.
Closed-Loop Insulin Therapy Improves Glycemic Control in Adolescents and Young Adults: Outcomes from the International Diabetes Closed-Loop Trial
Objective: To assess the efficacy and safety of closed-loop control (CLC) insulin delivery system in adolescents and young adults with type 1 diabetes. Research Design and Methods: Prespecified subanalysis of outcomes in adolescents and young adults aged 14–24 years old with type 1 diabetes in a previously published 6-month multicenter randomized trial. Participants were randomly assigned 2:1 to CLC (Tandem Control-IQ) or sensor augmented pump (SAP, various pumps+Dexcom G6 CGM) and followed for 6 months. Results: Mean age of the 63 participants was 17 years, median type 1 diabetes duration was 7 years, and mean baseline HbA1c was 8.1%. All 63 completed the trial. Time in range (TIR) increased by 13% with CLC versus decreasing by 1% with SAP (adjusted treatment group difference = +13% [+3.1 h/day]; 95% confidence interval [CI] 9–16, P < 0.001), which largely reflected a reduction in time >180 mg/dL (adjusted difference −12% [−2.9 h/day], P < 0.001). Time <70 mg/dL decreased by 1.6% with CLC versus 0.3% with SAP (adjusted difference −0.7% [−10 min/day], 95% CI −1.0% to −0.2%, P = 0.002). CLC use averaged 89% of the time for 6 months. The mean adjusted difference in HbA1c after 6 months was 0.30% in CLC versus SAP (95% CI −0.67 to +0.08, P = 0.13). There was one diabetic ketoacidosis episode in the CLC group. Conclusions: CLC use for 6 months was substantial and associated with improved TIR and reduced hypoglycemia in adolescents and young adults with type 1 diabetes. Thus, CLC has the potential to improve glycemic outcomes in this challenging age group. The clinical trial was registered with ClinicalTrials.gov (NCT03563313).
Clinical Management and Pump Parameter Adjustment of the Control-IQ Closed-Loop Control System: Results from a 6-Month, Multicenter, Randomized Clinical Trial
Background: Data are limited on the need for and benefits of pump setting optimization with automated insulin delivery. We examined clinical management of a closed-loop control (CLC) system and its relationship to glycemic outcomes. Materials and Methods: We analyzed personal parameter adjustments in 168 participants in a 6-month multicenter trial of CLC with Control-IQ versus sensor-augmented pump (SAP) therapy. Preset parameters (BR = basal rates, CF = correction factors, CR = carbohydrate ratios) were optimized at randomization, 2 and 13 weeks, for safety issues, participant concerns, or initiation by participants' usual diabetes care team. Time in range (TIR 70–180 mg/dL) was compared in the week before and after parameter changes. Results: In 607 encounters for parameter changes, there were fewer adjustments for CLC than SAP (3.4 vs. 4.1/participant). Adjustments involved BR (CLC 69%, SAP 80%), CR (CLC 68%, SAP 50%), CF (CLC 44%, SAP 41%), and overnight parameters (CLC 62%, SAP 75%). TIR before and after adjustments was 71.2% and 71.3% for CLC and 61.0% and 62.9% for SAP. The highest baseline HbA 1c CLC subgroup had the largest TIR improvement (51.2% vs. 57.7%). When a CR was made more aggressive in the CLC group, postprandial time >180 mg/dL was 43.1% before the change and 36.0% after the change. The median postprandial time <70 mg/dL before making CR less aggressive was 1.8%, and after the change was 0.7%. Conclusions: No difference in TIR was detected with parameter changes overall, but they may have an effect in higher HbA 1c subgroups or following user-directed boluses, suggesting that changes may matter more in suboptimal control or during discrete periods of the day. Clinical Trials Registration number: NCT03563313.
Use of the Interoperable Artificial Pancreas System for Type 1 Diabetes Management During Psychological Stress
OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14–72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70–180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P < 0.001). Time >180 mg/dL was lower in the CLC group than PLGS group (difference = −6.0%; 95% CI −8.4%, −3.7%; P < 0.001) while time <54 mg/dL was similar (0.04%; 95% CI −0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference −0.34% [−3.7 mmol/mol]; 95% CI −0.57% [−6.2 mmol/mol], −0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.