Back to Authors

Makkar, Raj

https://orcid.org/0000-0002-6613-519X

Mayo Clinic

Cedars-Sinai Medical Center

Citations 29

Standardized Definition of Structural Valve Degeneration for Surgical and Transcatheter Bioprosthetic Aortic Valves
Dvir, Danny , Bourguignon, Thierry , Rosenhek, Raphaël , Webb, John G. , Treede, Hendrik , Enriquez‐Sarano, Maurice , Feldman, Ted , Wijeysundera, Harindra C. , Topilsky, Yan , Aupart, Michel, Reardon, Michael J. , Szeto, Wilson Y. , Gammie, James S. , Yoganathan, Ajit P. , Arbel, Yaron , Borger, Michael A. , Simonato, Matheus , Reisman, Mark, Makkar, Raj , Abizaid, Alexandre , Dahle, Gry , Aldea, Gabriel S. , Leipsic, Jonathon , Pîbarot, Philippe , Moat, Neil, Mack, Michael J. , Leon, Martin B. , Topilsky, Yan , Sarano, Maurice E, Pibarot, Phillippe , Enriquez-Sarano, Maurice , Otto, Catherine M , Hahn, Rebecca T , Mackensen, G. Burkhard , Kornowski, Ran , McCabe, James M , Kappetein, A. Pieter , Topilsky, Yan , Reardon, Michael J , Abizaid, Alexandre

Circulation | January 22, 2018 | Volume: 137 | Issue: 4 | Pages: 388-399

10.1161/circulationaha.117.030729 Get It

Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.
Clinical Impact of Diabetes Mellitus on Outcomes After Transcatheter Aortic Valve Replacement
Abramowitz, Yigal, Vemulapalli, Sreekanth , Chakravarty, Tarun , Li, Zhuokai , Holmes, David R. , Wang, Alice , Cheng, Wen , Forrester, James S. , Smalling, Richard W. , Thourani, Vinod H. , Mack, Michael J. , Leon, Martin B. , Makkar, Raj , Douglas, Pamela S. , Matsouaka, Roland A, Smalling, Richard, Thourani, Vinod, Mack, Michael, Leon, Martin, Makkar, Raj R., Douglas, Pamela S , Kapadia, Samir , Matsouaka, Roland

Circulation: Cardiovascular Interventions | November 14, 2017 | Volume: 10 | Issue: 11 | Pages: No page available

10.1161/circinterventions.117.005417 Get It

Background— Diabetes mellitus (DM) adversely affects morbidity and mortality for cardiovascular diseases and procedures. Data evaluating the outcomes of transcatheter aortic valve replacement (TAVR) in diabetic patients are limited by small sample size and contradictory results. We aimed to establish the magnitude of risk and the incremental influence of insulin dependency by examining short- and long-term adverse outcomes according to DM status and therapy in the world’s largest TAVR registry. Methods and Results— We analyzed data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. In-hospital mortality, 30-day mortality, and 1-year mortality after TAVR in patients with and without DM were evaluated using multivariate modeling. Among 47 643 patients treated with TAVR from November 2011 through September 2015 at 394 US hospitals, there were 17 849 (37.5%) patients with DM. Overall, 6600 of the diabetic patients were insulin treated (IT). Thirty-day mortality was 5.0% in patients with DM (6.1% in IT DM and 4.4% in non-IT DM; P <0.001) versus 5.9% in patients without DM ( P <0.001). Overall, 1-year mortality was 21.8% in patients with DM (24.8% in IT DM and 20.1% in non-IT DM; P <0.001) versus 21.2% in patients without DM ( P =0.274). In a multivariable model, DM was associated with increased 1-year mortality (hazard ratio, 1.30; 95% confidence interval, 1.13–1.49; P <0.001). Subgroup multivariable analysis showed stronger mortality association in IT diabetics (hazard ratio, 1.57; 95% confidence interval, 1.28–1.91; P <0.001) than in non-IT diabetics (hazard ratio, 1.17; 95% confidence interval, 1.00–1.38; P =0.052). Conclusions— Our data establish the magnitude of short- and long-term risk conferred by DM and the incremental risk conferred by insulin dependency in the performance of TAVR. Clinical Trial Registration— URL: https://www.clinicaltrials.gov . Unique identifier: NCT01737528.
Transcatheter aortic valve replacement for stenotic bicuspid aortic valves: Systematic review and meta analyses of observational studies
Reddy, Gautam , Greason, Kevin L. , Yoon, Sung‐Han , Makkar, Raj , Holmes, David R. , Wang, Zhen , Nishimura, Rick A.

Catheterization and Cardiovascular Interventions | September 30, 2017 | Volume: 91 | Issue: 5 | Pages: 975-983

10.1002/ccd.27340 Get It

AbstractObjectiveThe aim of this study was to perform a systematic review and meta‐analyses of observational studies of transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve stenosis (BcAV).BackgroundTAVR for BcAV stenosis has been associated with an increased incidence of paravalvular leaks, valve malposition, pacemaker placement and all‐cause mortality. The conclusions drawn have been limited by small sample sizes. The use of TAVR for BcAV stenosis remains controversial.MethodsWe searched multiple databases from the inception of the databases through September 30, 2016 for studies of TAVR for BcAV stenosis. We included all observational studies with more than one patient and at least 1 month of outcomes.ResultsWe analyzed 13 observational studies with 758 patients. Meta analyses showed device success rate of 95% [95% confidence interval (CI) 90.2% to 98.5%] and an early safety event in 16.9% [95% CI 12.2% to 22%]. At 30 days, moderate to severe paravalvular leak was seen in 12.2% [95% CI 3.1% to 24.8%] and new pacemaker implantation in 17.9% [95% CI 14.2% to 22%]. All‐cause mortality was 3.7% [95% CI 2.1% to 5.6%], which should be viewed in the context of an STS PROM of 5.0%.ConclusionsThis analysis suggests that TAVR for BcAV is not associated with excess mortality. The incidence of paravalvular leaks and pacemaker implant is increased compared to tricuspid aortic valve cohorts undergoing TAVR, and operators should weigh these potential complications against the clinical benefit provided by TAVR for BcAV patients at high risk for surgical valve replacement.
One-Year Clinical Outcomes With SAPIEN 3 Transcatheter Aortic Valve Replacement in High-Risk and Inoperable Patients With Severe Aortic Stenosis
Thourani, Vinod H. , Kodali, Susheel , Makkar, Raj , Szeto, Wilson Y. , Anwaruddin, Saif , Lim, Scott, Kereiakes, Dean J. , Ramee, Steven, Greason, Kevin L. , Kapadia, Samir , Babaliaros, Vasilis , Pîbarot, Philippe , Weissman, Neil J., Leipsic, Jonathon , Webb, John G. , Mack, Michael J. , Leon, Martin B. , Douglas, Pamela S. , Makkar, Raj R., Desai, Nimesh, Whisenant, Brian K, Herrmann, Howard C. , Desai, Nimesh D. , Malaisrie, S. Chris , Hahn, Rebecca T , Pibarot, Phillippe , Whisenant, Brian K. , Douglas, Pamela S

Circulation | July 12, 2016 | Volume: 134 | Issue: 2 | Pages: 130-140

10.1161/circulationaha.116.022797 Get It

Background: In the initial PARTNER trial (Placement of Aortic Transcatheter Valves) of transcatheter aortic valve replacement for high-risk (HR) and inoperable patients, mortality at 1 year was 24% in HR and 31% in inoperable patients. A recent report of the 30-day outcomes with the low-profile SAPIEN 3 transcatheter aortic valve replacement system demonstrated very low rates of adverse events, but little is known about the longer-term outcomes with this device. Methods: Between October 2013 and September 2014, 583 HR (65%) or inoperable (35%) patients were treated via the transfemoral (84%) or transapical/transaortic (16%) access route at 29 US sites. Major clinical events at 1 year were adjudicated by an independent clinical events committee, and echocardiographic results were analyzed by a core laboratory. Results: Baseline characteristics included age of 83 years, 42% female, and median Society of Thoracic Surgeons score of 8.4%. At the 1-year follow-up, survival (all-cause) was 85.6% for all patients, 87.3% in the HR subgroup, and 82.3% in the inoperable subgroup. Survival free of all-cause and cardiovascular mortality in the transfemoral patients from the HR cohort was 87.7% and 93.3%, respectively. There was no severe paravalvular leak. Moderate paravalvular leak (2.7%) was associated with an increase in mortality at 1 year, whereas mild paravalvular leak had no significant association with mortality. Symptomatic improvement as assessed by the percentage of patients in New York Heart Association class III and IV (90.1% to 7.7% at 1 year; P <0.0001) and by Kansas City Cardiomyopathy Questionnaire overall summary score (improved from 46.9 to 72.4; P <0.0001) was marked. Multivariable predictors of 1-year mortality included alternative access, Society of Thoracic Surgeons score, and disabling stroke. Conclusions: In this large, adjudicated registry of SAPIEN 3 HR and inoperable patients, the very low rates of important complications resulted in a strikingly low mortality rate at 1 year. Between 30 and 365 days, the incidence of moderate paravalvular aortic regurgitation did not increase, and no association between mild paravalvular leak and 1-year mortality was observed, although a small increase in disabling stroke occurred. These results, which likely reflect device iteration and procedural evolution, support the use of transcatheter aortic valve replacement as the preferred therapy in HR and inoperable patients with aortic stenosis. Clinical Trial Registration : URL: http://www.clinicaltrials.gov . Unique identifier: NCT01314313.
Learning curves for transfemoral transcatheter aortic valve replacement in the PARTNER‐I trial: Success and safety
Minha, Sa’ar , Waksman, Ron , Satler, Lowell P., Torguson, Rebecca, Alli, Oluseun , Rihal, Charanjit S. , Mack, Michael J. , Svensson, Lars G. , Rajeswaran, Jeevanantham , Tuzcu, E. Murat , Thourani, Vinod H. , Makkar, Raj , Ehrlinger, John, Lowry, Ashley M. , Suri, Rakesh M. , Greason, Kevin L. , Leon, Martin B. , Holmes, David R. , Pichard, Augusto D., Rihal, Charanjit S. , Blackstone, Eugene H.

Catheterization and Cardiovascular Interventions | October 1, 2015 | Volume: 87 | Issue: 1 | Pages: 165-175

10.1002/ccd.26121 Get It

ObjectivesTo identify number of cases needed to maximize device success and minimize adverse events after transfemoral transcatheter aortic valve replacement (TF‐TAVR), and determine if adverse events were linked to the technical performance learning curve.BackgroundTF‐TAVR is a complex procedure with an incompletely characterized learning curve for clinical outcomes.MethodsFrom 4/2007–2/2012, 1521 patients underwent TF‐TAVR in the PARTNER‐I trial. Outcomes learning curves were defined as number of cases needed to reach a plateau for device success, adverse events, and post‐procedure length of stay. Institutional variation was accounted for by mixed‐model non‐linear techniques, which were also used to identify contribution of the procedure time learning curve to 30‐day major adverse events and length of stay.ResultsEighty percent device success was achieved after 22 cases; major vascular complications fell below 5% after 70 cases and major bleeding below 10% after 25 cases. It took an average of 28 cases to achieve a consistent low risk of 30‐day major adverse events, but institutions entering in the middle of the trial achieved it after about 26. The most significant correlate of 30‐day major adverse events and post‐procedure length of stay was procedure time (P < 0.0001). However, this association was related to patient and unmeasured variables, not the procedure time learning curve (P = 0.6).ConclusionsBy end of trial, a consistent low risk of adverse events was achieved after ∼26 cases. However, these improved results were due to change in patient risk profile; outcomes were not linked to the technical performance learning curve. © 2015 Wiley Periodicals, Inc.
Learning curves for transfemoral transcatheter aortic valve replacement in the PARTNER‐I trial: Technical performance
Alli, Oluseun , Rihal, Charanjit S. , Suri, Rakesh M. , Greason, Kevin L. , Waksman, Ron , Minha, Sa’ar , Torguson, Rebecca, Pichard, Augusto D., Mack, Michael J. , Svensson, Lars G. , Rajeswaran, Jeevanantham , Lowry, Ashley M. , Ehrlinger, John, Tuzcu, E. Murat , Thourani, Vinod H. , Makkar, Raj , Leon, Martin B. , Holmes, David R. , Rihal, Charanjit S. , Blackstone, Eugene H.

Catheterization and Cardiovascular Interventions | August 10, 2015 | Volume: 87 | Issue: 1 | Pages: 154-162

10.1002/ccd.26120 Get It

ObjectivesTo assess technical performance learning curves of teams performing transfemoral transcatheter aortic valve replacement (TF‐TAVR).BackgroundTF‐TAVR is a new procedure for treating severe aortic stenosis. The number of cases required for procedural efficiency is unknown.MethodsIn the PARTNER‐I trial, 1,521 patients underwent TF‐TAVR from 4/2007–2/2012. Learning curve analysis of technical performance metrics was performed using institution‐specific patient sequence number, interval between procedures, and institutional trial entry date. Learning curve characteristics were assessed using semi‐parametric and parametric mixed‐effects models.ResultsAs patient sequence number increased, average procedure time decreased from 154 to 85 minutes (P < 0.0001), and fluoroscopy time from 28 to 20 minutes (P < 0.0001). Procedure time plateaued at an average of 83 minutes (range 52–140). Procedure time plateau was dynamic during the course of the trial, averaging 25 cases (range 21–52) by its end. The later institutions enrolled in the trial, the shorter the initial procedure time. During the trial, percutaneous rather than surgical access increased from 7.9% to 69%.ConclusionsTechnical performance learning curves exist for TF‐TAVR; procedural efficiency increased with experience, with concomitant decreases in radiation and contrast media exposure. The number of cases needed to achieve efficiency decreased progressively, with optimal procedural performance reached after approximately 25 cases for late‐entering institutions. Knowledge and experience accumulated by early TF‐TAVR institutions were disseminated, shortening the learning curve of late‐entering institutions. Technological advances resulting from learning during the trial moved the field from initial conservative surgical cut‐down to percutaneous access for most patients. © 2015 Wiley Periodicals, Inc.
Response to Letter Regarding Article “Impact of Annual Operator and Institutional Volume on Percutaneous Coronary Intervention Outcomes: A 5-Year United States Experience (2005–2009)”
Badheka, Apurva O., Patel, Nileshkumar, Grover, Peeyush , Singh, Vikas , Patel, Nilay , Arora, Shilpkumar , Chothani, Ankit , Mehta, Kathan , Deshmukh, Abhishek , Savani, Ghanshyambhai T., Patel, Achint , Panaich, Sidakpal , Shah, Neeraj , Brown, Michael, Mohamad, Tamam , Makkar, Raj , Schreiber, Theodore , Rihal, Charanjit S. , Cohen, Mauricio G. , Rathod, Ankit D. , Grines, Cindy L. , Rihal, Charanjit S. , Panaich, Sidakpal S , Cohen, Mauricio G

Circulation | August 3, 2015 | Volume: 132 | Issue: 5 | Pages: No page available

10.1161/circulationaha.115.015221 Get It

Cardiopulmonary bypass and intra‐aortic balloon pump use is associated with higher short and long term mortality after transcatheter aortic valve replacement: A PARTNER trial substudy
Shreenivas, Satya , Lilly, Scott , Szeto, Wilson Y. , Anwaruddin, Saif , Bavaria, Joseph E. , Hudock, Kristin , Thourani, Vinod H. , Makkar, Raj , Pichard, Augusto D., Webb, John G. , Dewey, Todd, Suri, Rakesh M. , Xu, Ke , Leon, Martin B. , Desai, Nimesh D. , Kapadia, Samir , Herrmann, Howard C.

Catheterization and Cardiovascular Interventions | December 24, 2014 | Volume: 86 | Issue: 2 | Pages: 316-322

10.1002/ccd.25776 Get It

BackgroundTranscatheter aortic valve replacement (TAVR) with the balloon‐expandable Sapien transcatheter heart valve improves survival compared to standard therapy in patients with severe aortic stenosis (AS) and is noninferior to surgical aortic valve replacement (AVR) in patients at high operative risk. Nonetheless, a significant proportion of patients may require pre‐emptive or emergent support with cardiopulmonary bypass (CPB) and/or intra‐aortic balloon pump (IABP) during TAVR due to pre‐existing comorbid conditions or as a result of procedural complications. Objectives: We hypothesized that patients who required CPB or IABP would have increased periprocedural complications and reduced long‐term survival. In addition, we sought to determine whether preprocedural variables could predict the need for CPB and IABP. Methods: The study population included 2,525 patients in the PARTNER Trial (Cohort A and B) and the continuing access registry (CAR). Patients that received CPB or IABP were compared to patients that did not receive either, and then further divided into those that received support pre‐TAVR and those that were placed on support emergently. Results: One‐hundred sixty‐three patients (6.5%) were placed on CPB and/or IABP. The use of CPB or IABP was associated with higher 1 year mortality (49.1% vs. 21.6%, P < 0.001). In multivariable analysis, utilization of CPB or IABP was an independent predictor of 30 day (HR 6.95) and 1‐year (HR 2.56) mortality. Although mortality was highest in emergent cases, mortality was also greater in planned CPB and IABP cases compared with non‐CPB/IABP cases (53.3% and 40.3% vs. 21.6%, P < 0.001). Conclusions: These findings indicate that CPB and IABP use in TAVR portends a poor prognosis and its utilization, particularly in the setting of pre‐emptive use, needs reconsideration. © 2015 Wiley Periodicals, Inc.