Calibration of concomitant field offsets using phase contrast MRI for asymmetric gradient coils
Abad, Nastaren , Lee, Seung‐Kyun , Ajala, Afis , In, Myung‐Ho , Frigo, Louis M., Morris, H Douglas , Hua, Yihe , Ho, Vincent B. , Bernstein, Matt A. , Foo, Thomas , Bernstein, Matt A , Foo, Thomas K F , In, Myung-Ho , Bhushan, Chitresh

Magnetic Resonance in Medicine | September 21, 2022 | Volume: 89 | Issue: 1 | Pages: 262-275

10.1002/mrm.29452 Get It

PurposeAsymmetric gradient coils introduce zeroth‐ and first‐order concomitant field terms, in addition to higher‐order terms common to both asymmetric and symmetric gradients. Salient to compensation strategies is the accurate calibration of the concomitant field spatial offset parameters for asymmetric coils. A method that allows for one‐time calibration of the offset parameters is described.Theory and MethodsA modified phase contrast pulse sequence with single‐sided bipolar flow encoding is proposed to calibrate the offsets for asymmetric, transverse gradient coils. By fitting the measured phase offsets to different gradient amplitudes, the spatial offsets were calculated by fitting the phase variation. This was used for calibrating real‐time pre‐emphasis compensation of the zeroth‐ and first‐order concomitant fields.ResultsImage quality improvement with the proposed corrections was demonstrated in phantom and healthy volunteers with non‐Cartesian and Cartesian trajectory acquisitions. Concomitant field compensation using the calibrated offsets resulted in a residual phase error <3% at the highest gradient amplitude and demonstrated substantial reduction of image blur and slice position/selection artifacts.ConclusionsThe proposed implementation provides an accurate method for calibrating spatial offsets that can be used for real‐time concomitant field compensation of zeroth and first‐order terms, substantially reducing artifacts without retrospective correction or sequence specific waveform modifications.
Enhanced clinical task-based fMRI metrics through locally low-rank denoising of complex-valued data
Meyer, Nolan , Black, David F. , Welker, Kirk M. , Gray, Erin M. , In, Myung‐Ho , Shu, Yunhong , Trzasko, Joshua D. , Meyer, Nolan K , Huston Iii, John, In, Myung-Ho , Kang, Daehun , Campeau, Norbert G. , Huston, John , Bernstein, Matt A.

The Neuroradiology Journal | September 5, 2022 | Volume: 36 | Issue: 3 | Pages: 273-288

10.1177/19714009221122171 Get It

Objective This study investigates a locally low-rank (LLR) denoising algorithm applied to source images from a clinical task-based functional MRI (fMRI) exam before post-processing for improving statistical confidence of task-based activation maps. Methods Task-based motor and language fMRI was obtained in eleven healthy volunteers under an IRB approved protocol. LLR denoising was then applied to raw complex-valued image data before fMRI processing. Activation maps generated from conventional non-denoised (control) data were compared with maps derived from LLR-denoised image data. Four board-certified neuroradiologists completed consensus assessment of activation maps; region-specific and aggregate motor and language consensus thresholds were then compared with nonparametric statistical tests. Additional evaluation included retrospective truncation of exam data without and with LLR denoising; a ROI-based analysis tracked t-statistics and temporal SNR (tSNR) as scan durations decreased. A test-retest assessment was performed; retest data were matched with initial test data and compared for one subject. Results fMRI activation maps generated from LLR-denoised data predominantly exhibited statistically significant ( p = 4.88×10 –4 to p = 0.042; one p = 0.062) increases in consensus t-statistic thresholds for motor and language activation maps. Following data truncation, LLR data showed task-specific increases in t-statistics and tSNR respectively exceeding 20 and 50% compared to control. LLR denoising enabled truncation of exam durations while preserving cluster volumes at fixed thresholds. Test-retest showed variable activation with LLR data thresholded higher in matching initial test data. Conclusion LLR denoising affords robust increases in t-statistics on fMRI activation maps compared to routine processing, and offers potential for reduced scan duration while preserving map quality.
Rapid Geometry‐Corrected Echo‐Planar Diffusion Imaging at Ultrahigh Field: Fusing View Angle Tilting and Point‐Spread Function Mapping
Tung, Yi‐Hang , In, Myung‐Ho , Ahn, Sinyeob , Speck, Oliver , In, Myung-Ho

Magnetic Resonance in Medicine | June 28, 2022 | Volume: 88 | Issue: 5 | Pages: 2074-2087

10.1002/mrm.29360 Get It

PurposeSevere geometric distortions induced by tissue susceptibility, water–fat chemical shift, and eddy currents pose a substantial obstacle in single‐shot EPI, especially for high‐resolution imaging at ultrahigh field. View angle tilting (VAT)‐EPI can mitigate in‐plane distortion. However, the accompanied strong image blurring prevented its widespread applications. On the other hand, point‐spread function mapping (PSF)‐EPI can correct distortion and blurring accurately but requires prolonged scan time. We present fused VAT‐PSF‐EPI and possibilities for acceleration.MethodsMR signal equations were explicitly derived to quantify image blurring in VAT‐EPI and the maximum acceleration capacity in VAT‐PSF‐EPI. To validate the theoretical prediction, phantom measurements with varying in‐plane parallel imaging factors, slice thicknesses, and RF pulses were conducted at 7 Tesla. In addition, in vivo human brain scans were acquired with T2 and diffusion weighting to assess distortion and blurring correction.ResultsVAT can effectively suppress distortion, and the introduced image blurring is corrected through PSF encoding. Up to fourfold acceleration (only 5 shots) in VAT‐PSF‐EPI was achieved compared with standard PSF‐EPI without VAT. VAT‐induced signal loss was mitigated by adjusting the sequence parameters and EPI resolution. In vivo T2‐weighted EPI data with 1.4 mm3 resolution demonstrate immunity to water–fat chemical shift‐induced distortion. Very high‐spatial resolution diffusion‐weighted EPI (0.7 × 0.7 × 2.8 mm3 and 1.2 mm3) demonstrates the immunity to eddy current‐induced distortion.ConclusionVAT‐PSF‐EPI is a novel spin‐echo EPI‐based sequence for fast high‐resolution diffusion imaging at ultrahigh field.
Symptom-specific differential motor network modulation by deep brain stimulation in Parkinson’s disease
Gibson, William S. , Rusheen, Aaron E. , In, Myung‐Ho, Gorny, Krzysztof R. , Felmlee, Joel P. , Klassen, Bryan T. , Jung, Sung Jun , Min, Hoon‐Ki , Lee, Kendall H. , In, Myung‐Ho , Min, Hoon-Ki Paul , In, Myung-Ho , Gibson, William S., Oh, Yoonbae , Jo, Hang Joon

Journal of Neurosurgery | May 14, 2021 | Volume: 135 | Issue: 6 | Pages: 1771-1779

10.3171/2020.10.jns202277 Get It

OBJECTIVE Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an established neurosurgical treatment for the motor symptoms of Parkinson’s disease (PD). While often highly effective, DBS does not always yield optimal therapeutic outcomes, and stimulation-induced adverse effects, including paresthesia, muscle contractions, and nausea/lightheadedness, commonly occur and can limit the efficacy of stimulation. Currently, objective metrics do not exist for monitoring neural changes associated with stimulation-induced therapeutic and adverse effects. METHODS In the present study, the authors combined intraoperative functional MRI (fMRI) with STN DBS in 20 patients with PD to test the hypothesis that stimulation-induced blood oxygen level–dependent signals contained predictive information concerning the therapeutic and adverse effects of stimulation. RESULTS As expected, DBS resulted in blood oxygen level–dependent activation in myriad motor regions, including the primary motor cortex, caudate, putamen, thalamus, midbrain, and cerebellum. Across the patients, DBS-induced improvements in contralateral Unified Parkinson’s Disease Rating Scale tremor subscores correlated with activation of thalamic, brainstem, and cerebellar regions. In addition, improvements in rigidity and bradykinesia subscores correlated with activation of the primary motor cortex. Finally, activation of specific sensorimotor-related subregions correlated with the presence of DBS-induced adverse effects, including paresthesia and nausea (cerebellar cortex, sensorimotor cortex) and unwanted muscle contractions (caudate and putamen). CONCLUSIONS These results suggest that DBS-induced activation patterns revealed by fMRI contain predictive information with respect to the therapeutic and adverse effects of DBS. The use of fMRI in combination with DBS therefore may hold translational potential to guide and improve clinical stimulator optimization in patients.
The effect of spiral trajectory correction on pseudo‐continuous arterial spin labeling with high‐performance gradients on a compact 3T scanner
Kang, Daehun , Yarach, Uten , In, Myung‐Ho , Gray, Erin M. , Trzasko, Joshua D. , Shu, Yunhong , Bernstein, Matt A. , Bernstein, Matt A , Kang, Daehun , In, Myung-Ho , Jo, Hang Joon , Huston, John

Magnetic Resonance in Medicine | December 4, 2019 | Volume: 84 | Issue: 1 | Pages: 192-205

10.1002/mrm.28110 Get It

PurposeTo demonstrate the feasibility of pseudo‐continuous arterial‐spin–labeled (pCASL) imaging with 3D fast‐spin‐echo stack‐of‐spirals on a compact 3T scanner (C3T), to perform trajectory correction for eddy‐current–induced deviations in the spiral readout of pCASL imaging, and to assess the correction effect on perfusion‐related images with high‐performance gradients (80 mT/m, 700T/m/s) of the C3T.MethodsTo track eddy‐current–induced artifacts with Archimedean spiral readout, the spiral readout in pCASL imaging was performed with 5 different peak gradient slew rate (Smax) values ranging from 70 to 500 T/m/s. The trajectory for each Smax was measured using a dynamic field camera and applied in a density‐compensated gridding image reconstruction in addition to the nominal trajectory. The effect of the trajectory correction was assessed with perfusion‐weighted (ΔM) images and proton‐density–weighted images as well as cerebral blood flow (CBF) maps, obtained from 10 healthy volunteers.ResultsBlurring artifact on ΔM images was mitigated by the trajectory correction. CBF values on the left and right calcarine cortices showed no significant difference after correction. Also, the signal‐to‐noise ratio of ΔM images improved, on average, by 7.6% after correction (P < .001). The greatest improvement of 12.1% on ΔM images was achieved with a spiral readout using Smax of 300~400 T/m/s.ConclusionEddy currents can cause spiral trajectory deviation, which leads to deformation of the CBF map even in cases of low value Smax. The trajectory correction for spiral‐readout–based pCASL produces more reliable results for perfusion imaging. These results suggest that pCASL is feasible on C3T with high‐performance gradients.
Resting‐state functional connectivity modulates the BOLD activation induced by nucleus accumbens stimulation in the swine brain
Cho, Shinho , Hachmann, Jan T. , Balzekas, Irena , In, Myung‐Ho, Andres‐Beck, Lindsey G., Lee, Kendall H. , Min, Hoon‐Ki , In, Myung‐Ho , Jo, Hang Joon , Min, Hoon-Ki Paul , In, Myung-Ho , Jo, Hang Joon

Brain and Behavior | November 7, 2019 | Volume: 9 | Issue: 12 | Pages: No page available

10.1002/brb3.1431 Get It

Abstract Introduction While the clinical efficacy of deep brain stimulation (DBS) the treatment of motor‐related symptoms is well established, the mechanism of action of the resulting cognitive and behavioral effects has been elusive. Methods By combining functional magnetic resonance imaging (fMRI) and DBS, we investigated the pattern of blood‐oxygenation‐level‐dependent (BOLD) signal changes induced by stimulating the nucleus accumbens in a large animal model. Results We found that diffused BOLD activation across multiple functional networks, including the prefrontal, limbic, and thalamic regions during the stimulation, resulted in a significant change in inter‐regional functional connectivity. More importantly, the magnitude of the modulation was closely related to the strength of the inter‐regional resting‐state functional connectivity. Conclusions Nucleus accumbens stimulation affects the functional activity in networks that underlie cognition and behavior. Our study provides an insight into the nature of the functional connectivity, which mediates activation effect via brain networks.
Distortion‐free imaging: A double encoding method (DIADEM) combined with multiband imaging for rapid distortion‐free high‐resolution diffusion imaging on a compact 3T with high‐performance gradients
In, Myung‐Ho , Tan, Ek T. , Trzasko, Joshua D. , Shu, Yunhong , Yarach, Uten , Tao, Shengzhen , Gray, Erin M. , Tao, Shengzhen , Tan, Ek T , Kang, Daehun , Huston, John , Bernstein, Matt A. , In, Myung-Ho

Journal of Magnetic Resonance Imaging | May 21, 2019 | Volume: 51 | Issue: 1 | Pages: 296-310

10.1002/jmri.26792 Get It

BackgroundDistortion‐free, high‐resolution diffusion imaging using DIADEM (Distortion‐free Imaging: A Double Encoding Method), proposed recently, has great potential for clinical applications. However, it can suffer from prolonged scan times and its reliability for quantitative diffusion imaging has not been evaluated.PurposeTo investigate the clinical feasibility of DIADEM‐based high‐resolution diffusion imaging on a novel compact 3T (C3T) by evaluating the reliability of quantitative diffusion measurements and utilizing both the high‐performance gradients (80 mT/m, 700 T/m/s) and the sequence optimization with the navigator acquisition window reduction and simultaneous multislice (multiband) imaging.Study TypeProspective feasibility study.Phantom/SubjectsDiffusion quality control phantom scans to evaluate the reliability of quantitative diffusion measurements; 36 normal control scans for B0‐field mapping; six healthy and two patient subject scans with a brain tumor for comparisons of diffusion and anatomical imaging.Field Strength/Sequence3T; the standard single‐shot echo‐planar‐imaging (EPI), multishot DIADEM diffusion, and anatomical (2D‐FSE [fast‐spin‐echo], 2D‐FLAIR [fluid‐attenuated‐inversion‐recovery], and 3D‐MPRAGE [magnetization prepared rapid acquisition gradient echo]) imaging.AssessmentThe scan time reduction, the reliability of quantitative diffusion measurements, and the clinical efficacy for high‐resolution diffusion imaging in healthy control and brain tumor volunteers.Statistical TestBland–Altman analysis.ResultsThe scan time for high in‐plane (0.86 mm2) resolution, distortion‐free, and whole brain diffusion imaging were reduced from 10 to 5 minutes with the sequence optimizations. All of the mean apparent diffusion coefficient (ADC) values in phantom were within the 95% confidence interval in the Bland–Altman plot. The proposed acquisition with a total off‐resonance coverage of 597.2 Hz wider than the expected bandwidth of 500 Hz in human brain could yield a distortion‐free image without foldover artifacts. Compared with EPI, therefore, this approach allowed direct image matching with the anatomical images and enabled improved delineation of the tumor boundaries.Data ConclusionThe proposed high‐resolution diffusion imaging approach is clinically feasible on C3T due to a combination of hardware and sequence improvements.Level of Evidence3Technical EfficacyStage 1 J. Magn. Reson. Imaging 2020;51:296–310.
Dynamic 2D self‐phase‐map Nyquist ghost correction for simultaneous multi‐slice echo planar imaging
Yarach, Uten , Tung, Yi‐Hang , Setsompop, Kawin , In, Myung‐Ho , Chatnuntawech, Itthi , Yakupov, Renat , Godenschweger, Frank, Speck, Oliver , In, Myung-Ho

Magnetic Resonance in Medicine | February 10, 2018 | Volume: 80 | Issue: 4 | Pages: 1577-1587

10.1002/mrm.27123 Get It

PurposeTo develop a reconstruction pipeline that intrinsically accounts for both simultaneous multislice echo planar imaging (SMS‐EPI) reconstruction and dynamic slice‐specific Nyquist ghosting correction in time‐series data.MethodsAfter 1D slice‐group average phase correction, the separate polarity (i.e., even and odd echoes) SMS‐EPI data were unaliased by slice GeneRalized Autocalibrating Partial Parallel Acquisition. Both the slice‐unaliased even and odd echoes were jointly reconstructed using a model‐based framework, extended for SMS‐EPI reconstruction that estimates a 2D self‐phase map, corrects dynamic slice‐specific phase errors, and combines data from all coils and echoes to obtain the final images.ResultsThe percentage ghost‐to‐signal ratios (%GSRs) and its temporal variations for MB3Ry2 with a field of view/4 shift in a human brain obtained by the proposed dynamic 2D and standard 1D phase corrections were 1.37 ± 0.11 and 2.66 ± 0.16, respectively. Even with a large regularization parameter λ applied in the proposed reconstruction, the smoothing effect in fMRI activation maps was comparable to a very small Gaussian kernel size 1 × 1 × 1 mm3.ConclusionThe proposed reconstruction pipeline reduced slice‐specific phase errors in SMS‐EPI, resulting in reduction of GSR. It is applicable for functional MRI studies because the smoothing effect caused by the regularization parameter selection can be minimal in a blood‐oxygen‐level–dependent activation map.
Reduced acoustic noise in diffusion tensor imaging on a compact MRI system
Tan, Ek T. , Hardy, Christopher J., Shu, Yunhong , In, Myung‐Ho , Guidon, Arnaud , Bernstein, Matt A. , Foo, Thomas , Bernstein, Matt A , Foo, Thomas K F , Tan, Ek T , Huston, John , In, Myung-Ho

Magnetic Resonance in Medicine | October 3, 2017 | Volume: 79 | Issue: 6 | Pages: 2902-2911

10.1002/mrm.26949 Get It

PurposeTo investigate the feasibility of substantially reducing acoustic noise while performing diffusion tensor imaging (DTI) on a compact 3T (C3T) MRI scanner equipped with a 42‐cm inner‐diameter asymmetric gradient.MethodsA‐weighted acoustic measurements were made using 10 mT/m‐amplitude sinusoidal waveforms, corresponding to echo‐planar imaging (EPI) echo spacing of 0.25 to 5.0 ms, on a conventional, whole‐body 3T MRI and on the C3T. Acoustic measurements of DTI with trapezoidal EPI waveforms were then made at peak gradient performance on the C3T (80 mT/m amplitude, 700 T/m/s slew rate) and at derated performance (33 mT/m, 10 to 50 T/m/s) for acoustic noise reduction. DTI was acquired in two different phantoms and in seven human subjects, with and without gradient‐derating corresponding to multi‐ and single‐shot acquisitions, respectively.ResultsSinusoidal waveforms on the C3T were quieter by 8.5 to 15.6 A‐weighted decibels (dBA) on average as compared to the whole‐body MRI. The derated multishot DTI acquisition noise level was only 8.7 dBA (at 13 T/m/s slew rate) above ambient, and was quieter than non‐derated, single‐shot DTI by 22.3 dBA; however, the scan time was almost quadrupled. Although derating resulted in negligible diffusivity differences in the phantoms, small biases in diffusivity measurements were observed in human subjects (apparent diffusion coefficient = +9.3 ± 8.8%, fractional anisotropy = +3.2 ± 11.2%, radial diffusivity = +9.4 ± 16.8%, parallel diffusivity = +10.3 ± 8.4%).ConclusionThe feasibility of achieving reduced acoustic noise levels with whole‐brain DTI on the C3T MRI was demonstrated. Magn Reson Med 79:2902–2911, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Model‐based iterative reconstruction for single‐shot EPI at 7 T
Yarach, Uten , In, Myung‐Ho , Chatnuntawech, Itthi , Bilgiç, Berkin , Godenschweger, Frank, Mattern, Hendrik , Sciarra, Alessandro , Speck, Oliver , Bilgic, Berkin , In, Myung-Ho

Magnetic Resonance in Medicine | February 10, 2017 | Volume: 78 | Issue: 6 | Pages: 2250-2264

10.1002/mrm.26633 Get It

Purpose To describe a model‐based reconstruction strategy for single‐shot echo planar imaging (EPI) that intrinsically accounts for k‐space nonuniformity, Nyquist ghosting, and geometric distortions during rather than before or after image reconstruction. Methods Ramp sampling and inhomogeneous B0 field‐induced distortion cause the EPI samples to lie on a non‐Cartesian grid, thus requiring the nonuniform fast Fourier transform. Additionally, a 2D Nyquist ghost phase correction without the need for extra navigator acquisition is included in the proposed reconstruction. Coil compression is also incorporated to reduce the computational load. The proposed method is applied to phantom and human brain MRI data. Results The results demonstrate that Nyquist ghosting and geometric distortions are reduced by the proposed reconstruction. The proposed 2D phase correction is superior to a conventional 1D correction. The reductions of both artifacts lead to improved temporal signal‐to‐noise ratio (tSNR). The virtual coil results suggest that the processing time can be reduced by up to 75%, with a mean tSNR loss of only 3.2% when using 8‐virtual instead of 32‐physical coils for twofold undersampled data. Conclusion The proposed reconstruction improves the quality (ghosting, geometry, and tSNR) of EPI without requiring calibration data for Nyquist ghost correction. Magn Reson Med 78:2250–2264, 2017. © 2017 International Society for Magnetic Resonance in Medicine.