Back to Authors

Godenschweger, Frank

Mayo Clinic

Otto-von-Guericke-Universität Magdeburg

Citations 2

Dynamic 2D self‐phase‐map Nyquist ghost correction for simultaneous multi‐slice echo planar imaging
Yarach, Uten , Tung, Yi‐Hang , Setsompop, Kawin , In, Myung‐Ho , Chatnuntawech, Itthi , Yakupov, Renat , Godenschweger, Frank, Speck, Oliver , In, Myung-Ho

Magnetic Resonance in Medicine | February 10, 2018 | Volume: 80 | Issue: 4 | Pages: 1577-1587

10.1002/mrm.27123 Get It

PurposeTo develop a reconstruction pipeline that intrinsically accounts for both simultaneous multislice echo planar imaging (SMS‐EPI) reconstruction and dynamic slice‐specific Nyquist ghosting correction in time‐series data.MethodsAfter 1D slice‐group average phase correction, the separate polarity (i.e., even and odd echoes) SMS‐EPI data were unaliased by slice GeneRalized Autocalibrating Partial Parallel Acquisition. Both the slice‐unaliased even and odd echoes were jointly reconstructed using a model‐based framework, extended for SMS‐EPI reconstruction that estimates a 2D self‐phase map, corrects dynamic slice‐specific phase errors, and combines data from all coils and echoes to obtain the final images.ResultsThe percentage ghost‐to‐signal ratios (%GSRs) and its temporal variations for MB3Ry2 with a field of view/4 shift in a human brain obtained by the proposed dynamic 2D and standard 1D phase corrections were 1.37 ± 0.11 and 2.66 ± 0.16, respectively. Even with a large regularization parameter λ applied in the proposed reconstruction, the smoothing effect in fMRI activation maps was comparable to a very small Gaussian kernel size 1 × 1 × 1 mm3.ConclusionThe proposed reconstruction pipeline reduced slice‐specific phase errors in SMS‐EPI, resulting in reduction of GSR. It is applicable for functional MRI studies because the smoothing effect caused by the regularization parameter selection can be minimal in a blood‐oxygen‐level–dependent activation map.
Model‐based iterative reconstruction for single‐shot EPI at 7 T
Yarach, Uten , In, Myung‐Ho , Chatnuntawech, Itthi , Bilgiç, Berkin , Godenschweger, Frank, Mattern, Hendrik , Sciarra, Alessandro , Speck, Oliver , Bilgic, Berkin , In, Myung-Ho

Magnetic Resonance in Medicine | February 10, 2017 | Volume: 78 | Issue: 6 | Pages: 2250-2264

10.1002/mrm.26633 Get It

Purpose To describe a model‐based reconstruction strategy for single‐shot echo planar imaging (EPI) that intrinsically accounts for k‐space nonuniformity, Nyquist ghosting, and geometric distortions during rather than before or after image reconstruction. Methods Ramp sampling and inhomogeneous B0 field‐induced distortion cause the EPI samples to lie on a non‐Cartesian grid, thus requiring the nonuniform fast Fourier transform. Additionally, a 2D Nyquist ghost phase correction without the need for extra navigator acquisition is included in the proposed reconstruction. Coil compression is also incorporated to reduce the computational load. The proposed method is applied to phantom and human brain MRI data. Results The results demonstrate that Nyquist ghosting and geometric distortions are reduced by the proposed reconstruction. The proposed 2D phase correction is superior to a conventional 1D correction. The reductions of both artifacts lead to improved temporal signal‐to‐noise ratio (tSNR). The virtual coil results suggest that the processing time can be reduced by up to 75%, with a mean tSNR loss of only 3.2% when using 8‐virtual instead of 32‐physical coils for twofold undersampled data. Conclusion The proposed reconstruction improves the quality (ghosting, geometry, and tSNR) of EPI without requiring calibration data for Nyquist ghost correction. Magn Reson Med 78:2250–2264, 2017. © 2017 International Society for Magnetic Resonance in Medicine.