Back to Authors

Bilgiç, Berkin

https://orcid.org/0000-0002-9080-7865

Mayo Clinic

Harvard University

Citations 2

Recommended implementation of quantitative susceptibility mapping for clinical research in the brain: A consensus of the ISMRM electro‐magnetic tissue properties study group
Bilgiç, Berkin , Costagli, Mauro , Chan, Kwok‐Shing , Duyn, Jeff H. , Lee, Jongho , Li, Xu , Liu, Chunlei , Marques, José P. , Schweser, Ferdinand , Straub, Sina , Group, ISMRM Electro‐Magnetic Tissue Properties Study, Bilgic, Berkin , Costagli, Mauro , Chan, Kwok-Shing , Langkammer, Christian , Lee, Jongho , Li, Xu , Liu, Chunlei , Marques, José P , Robinson, Simon Daniel , Schweser, Ferdinand , Shmueli, Karin , Spincemaille, Pascal , Straub, Sina , Milovic, Carlos , Spincemaille, Pascal , Zijl, Peter C.M. van , Wang, Yi , Group, ISMRM Electro‐Magnetic Tissue Properties Study

Magnetic Resonance in Medicine | January 22, 2024 | Volume: 91 | Issue: 5 | Pages: 1834-1862

10.1002/mrm.30006 Get It

AbstractThis article provides recommendations for implementing QSM for clinical brain research. It is a consensus of the International Society of Magnetic Resonance in Medicine, Electro‐Magnetic Tissue Properties Study Group. While QSM technical development continues to advance rapidly, the current QSM methods have been demonstrated to be repeatable and reproducible for generating quantitative tissue magnetic susceptibility maps in the brain. However, the many QSM approaches available have generated a need in the neuroimaging community for guidelines on implementation. This article outlines considerations and implementation recommendations for QSM data acquisition, processing, analysis, and publication. We recommend that data be acquired using a monopolar 3D multi‐echo gradient echo (GRE) sequence and that phase images be saved and exported in Digital Imaging and Communications in Medicine (DICOM) format and unwrapped using an exact unwrapping approach. Multi‐echo images should be combined before background field removal, and a brain mask created using a brain extraction tool with the incorporation of phase‐quality‐based masking. Background fields within the brain mask should be removed using a technique based on SHARP or PDF, and the optimization approach to dipole inversion should be employed with a sparsity‐based regularization. Susceptibility values should be measured relative to a specified reference, including the common reference region of the whole brain as a region of interest in the analysis. The minimum acquisition and processing details required when reporting QSM results are also provided. These recommendations should facilitate clinical QSM research and promote harmonized data acquisition, analysis, and reporting.
Model‐based iterative reconstruction for single‐shot EPI at 7 T
Yarach, Uten , In, Myung‐Ho , Chatnuntawech, Itthi , Bilgiç, Berkin , Godenschweger, Frank, Mattern, Hendrik , Sciarra, Alessandro , Speck, Oliver , Bilgic, Berkin , In, Myung-Ho

Magnetic Resonance in Medicine | February 10, 2017 | Volume: 78 | Issue: 6 | Pages: 2250-2264

10.1002/mrm.26633 Get It

Purpose To describe a model‐based reconstruction strategy for single‐shot echo planar imaging (EPI) that intrinsically accounts for k‐space nonuniformity, Nyquist ghosting, and geometric distortions during rather than before or after image reconstruction. Methods Ramp sampling and inhomogeneous B0 field‐induced distortion cause the EPI samples to lie on a non‐Cartesian grid, thus requiring the nonuniform fast Fourier transform. Additionally, a 2D Nyquist ghost phase correction without the need for extra navigator acquisition is included in the proposed reconstruction. Coil compression is also incorporated to reduce the computational load. The proposed method is applied to phantom and human brain MRI data. Results The results demonstrate that Nyquist ghosting and geometric distortions are reduced by the proposed reconstruction. The proposed 2D phase correction is superior to a conventional 1D correction. The reductions of both artifacts lead to improved temporal signal‐to‐noise ratio (tSNR). The virtual coil results suggest that the processing time can be reduced by up to 75%, with a mean tSNR loss of only 3.2% when using 8‐virtual instead of 32‐physical coils for twofold undersampled data. Conclusion The proposed reconstruction improves the quality (ghosting, geometry, and tSNR) of EPI without requiring calibration data for Nyquist ghost correction. Magn Reson Med 78:2250–2264, 2017. © 2017 International Society for Magnetic Resonance in Medicine.