Back to Authors

Mulpuru, Siva K

0000-0002-7694-3617

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.

Citations 20

Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States
Fatunde, Olubadewa A. , Vemulapalli, Hema Srikanth , Rodriguez, Juan F. , Rodriguez-Riascos, Juan F , Vemulapalli, Hema S , Somappa, Aakash , Estrada-Vargas, Camilo A , Fatunde, Olubadewa A , Prajapati, Poojan , Vijayakumar, Keerthika , Kapa, Suraj , Nguyen, Duy, Asirvatham, Samuel J , McLeod, Christopher J , El Masry, Hicham , Deshmukh, Abhishek J , Kella, Danesh K , Killu, Ammar M , Mulpuru, Siva K , Sardana, Mayank , Scott, Luis R , Sugrue, Alan M, Srivathsan, Komandoor , Prasitlumkum, Narut , Rojas, Carlos, Prajapati, Poojan , Vijayakumar, Keerthika , Kapa, Suraj , Nguyen, Duy, Asirvatham, Samuel J. , Madhavan, Malini , McLeod, Christopher J. , Masry, Hicham El , Deshmukh, Abhishek , Kella, Danesh , Killu, Ammar M. , Mulpuru, Siva K. , Scott, Luis R. , Sugrue, Alan , Srivathsan, Komandoor

Journal of Cardiovascular Electrophysiology | September 15, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/jce.70503 Get It

ABSTRACT Background Pulsed field ablation (PFA) is an emerging non‐thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited. Objective To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real‐world US registry. Methods This retrospective study included consecutive patients undergoing PFA for ventricular tachycardia (VT) or premature ventricular contractions (PVCs) at three Mayo Clinic centers (April 2024 to July 2025). The primary feasibility outcome was the successful delivery of PFA lesions to the intended target substrate. Primary efficacy outcomes included acute procedural success; sustained VT recurrence requiring implantable cardioverter‐defibrillator (ICD) shocks or multiple antitachycardia pacing therapies; and ≥ 80% reduction in PVC burden. Safety outcomes included procedural complications, valvular function, thromboembolic events, renal function, and conduction disturbances. Results Twenty‐six patients were included (13 PVC, 13 VT). Acute success was achieved in all VT ablations (69.2% complete; 30.8% partial) and in 92.3% of PVC ablations. Complications occurred in 11.5% of patients (transient LBBB [ n = 1] and vascular complications [ n = 2]). No thromboembolic events, intracardiac thrombus, or acute kidney injury were observed. Lesions near the mitral valve apparatus did not worsen mitral regurgitation, including in patients with pre‐existing valve disease. After a median follow‐up of 365 days, one patient experienced VT recurrence requiring ICD shocks. Estimated recurrence‐free survival after VT ablation was 61.5% at 12 months; 58.3% of PVC patients achieved ≥ 80% burden reduction. Conclusion PFA for VA appears feasible and acutely effective, with a low rate of procedure‐related complications. While acute success was high, long‐term outcomes were acceptable for VT ablation and relatively modest for PVC ablation, highlighting the need for continued refinement of technology and energy‐delivery strategies. Larger prospective studies are warranted.
First-in-Human Clinical Experience With Focal Pulsed Field and Radiofrequency Dual-Modality Ablation for Treatment Refractory Left Ventricular Summit PVCs
Patil, Shivaraj, Liu, Xiaoke Ken, Siontis, Konstantinos C. , Prasitlumkum, Narut , Asirvatham, S, Cha, Yong‐Mei , Munoz, Freddy Del‐Carpio , Deshmukh, Abhishek , DeSimone, Christopher V. , Friedman, Paul A. , Madhavan, Malini , Mulpuru, S K, Munger, Thomas, Nguyen, Duy T. , Tan, N, Sugrue, Alan , Killu, Ammar M. , Asirvatham, Samuel J. , Liu, Xiaoke , Asirvatham, Samuel J , Del-Carpio Munoz, Freddy , Deshmukh, Abhishek J , Ezzeddine, Fatima , Friedman, Paul A , Kowlgi, Narayan G , Madhavan, Malini , Mulpuru, Siva K , Nguyen, Duy, Noseworthy, Peter A , Tan, Nicholas , Sugrue, Alan , Kapa, Suraj , Killu, Ammar M , DeSimone, Christopher V , Prasitlumkum, Narut , Ezzeddine, Fatima M. , Kowlgi, Gurukripa N. , Mulpuru, Siva K. , Munger, Thomas M., Noseworthy, Peter A. , Kapa, Suraj

Circulation: Arrhythmia and Electrophysiology | April 24, 2026 | Volume: 19 | Issue: 6 | Pages: No page available

10.1161/circep.126.014942 Get It

BACKGROUND: Radiofrequency (RF) ablation of premature ventricular complexes (PVCs) originating from the left ventricular summit may be unsuccessful, highlighting the need for alternative approaches. We aimed to assess the efficacy and safety of a novel dual-modality focal catheter in treating left ventricular summit PVCs in patients who had failed previous RF ablation. METHODS: Patients were prospectively enrolled and underwent a redo ablation procedure using an irrigated, contact-force sensing, dual-modality focal catheter (TactiFlex Duo, Abbott) under compassionate use indication. The ablation strategy, including the choice of energy modality (monopolar pulsed field [PF], RF, or both), was left to the operator’s discretion. Safety assessments included serial biomarkers, renal function, and CMR within 36 hours. Efficacy was defined as ≥80% reduction in PVC burden with symptom resolution at 3-month follow-up. RESULTS: Six consecutive patients (4 men; mean age, 53.8±15 years) with symptomatic left ventricular summit PVCs and a prior failed RF ablation (range, 1–2) were prospectively enrolled. All PVCs had an inferior axis, with a left bundle V1 morphology observed in 4 of 6 cases (mean burden, 30.1±5.3%). Acute suppression of PVCs was achieved in all cases. Acute suppression with a single PF application in the great cardiac vein-anterior interventricular vein occurred in 2 patients, while 3 patients required additional RF, PF, or combined RF+PF applications at adjacent sites. One patient with an inaccessible great cardiac vein-anterior interventricular vein was successfully treated in the left ventricular outflow tract with RF+PF application. Transient, reversible left anterior descending vasospasm was observed during PF delivery in 2 of 5 cases that underwent PF application adjacent to a coronary artery, despite pretreatment with intracoronary nitroglycerin without ECG or hemodynamic sequelae. All patients had durable suppression of PVCs at follow-up. CONCLUSIONS: In its first human application, dual-modality ablation was feasible and effective for refractory left ventricular summit PVCs. Transient coronary vasospasm occurred, though it was reversible and without acute clinical consequences.
Sex, Race, and Socioeconomic Disparities in the Utilization of Transvenous Lead Removal for Patients Hospitalized With Cardiac Implantable Electronic Device Infections in the United States
Elbenawi, Hossam , Patel, Harsh , Munir, Muhammad Bilal , Lee, Justin Z. , Tan, Nicholas Y. , Sugrue, Alan , Friedman, Paul A. , Asirvatham, Samuel J. , Mulpuru, Siva K. , Cha, Yong‐Mei , Deshmukh, Abhishek , Agarwal, Siddharth , Munir, Muhammad Bilal , Kowlgi, Gurukripa N. , Tan, Nicholas , Sugrue, Alan , Friedman, Paul A , Asirvatham, Samuel J , Mulpuru, Siva K , Cha, Yong-Mei , Deshmukh, Abhishek J , DeSimone, Christopher V , Agarwal, Siddharth , Agarwal, Siddharth, Asad, Zain Ul Abideen , DeSimone, Daniel C. , DeSimone, Christopher V.

Journal of Cardiovascular Electrophysiology | June 12, 2025 | Volume: 36 | Issue: 8 | Pages: 1938-1947

10.1111/jce.16758 Get It

ABSTRACT Background Transvenous lead removal (TLR) is a Class I indication for patients with cardiac implantable electronic device (CIED) infections. However, disparities in the utilization of TLR have not been fully explored, particularly concerning demographic and socioeconomic factors. Objectives This study aims to examine whether disparities exist among patients hospitalized for CIED infections with respect to the utilization of TLR, focusing on sex, race, and income characteristics. Methods We utilized the 2019 National Inpatient Sample (NIS) to assess patients hospitalized with CIED infections and identify those who underwent TLR. Multiple logistic regression was used to examine risk factors for TLR utilization, including age, sex, race/ethnicity, and socioeconomic characteristics. Results A total of 56 709 patients were hospitalized for CIED infection in the United States in 2019, of which 9867 (17.4%) underwent TLR. On an adjusted analysis, females and Black patients were found to have lower odds of undergoing TLR compared to males and White patients (OR: 0.62; 95% CI: 0.59–0.78; p < 0.01; and OR: 0.47; 95% CI: 0.39–0.57; p < 0.01, respectively). Hispanic patients also had reduced odds of TLR (OR: 0.73; 95% CI: 0.58–0.93; p = 0.01). No significant associations were observed between income or insurance status and the likelihood of receiving TLR after adjustment. Conclusions This study identified significant disparities in the utilization of TLR among patients hospitalized for CIED infections. Female, Black, and Hispanic patients were significantly less likely to receive TLR.
First‐in‐man report of transsubclavian venous implantation of the Aveir leadless cardiac pacing system
Ward, Robert C. , Amin, Hina , Noseworthy, Peter A. , Asirvatham, Samuel J. , Friedman, Paul A. , Mulpuru, Siva K. , Balanescu, Dinu V , Ward, Robert C , Noseworthy, Peter A , Asirvatham, Samuel J , Friedman, Paul A , Mulpuru, Siva K , Balanescu, Dinu Valentin

Journal of Cardiovascular Electrophysiology | March 11, 2024 | Volume: 35 | Issue: 5 | Pages: 1041-1045

10.1111/jce.16241 Get It

Abstract Introduction Transsubclavian venous implantation of the Aveir leadless cardiac pacemaker (LCP) has not been previously reported. Methods and Results Three cases of transsubclavian implantation of the Aveir LCP are reported. Two cases were postbilateral orthotopic lung transplant, without appropriate femoral or jugular access due to recent ECMO cannulation and jugular central venous catheters. In one case, there was strong patient preference for same‐day discharge. Stability testing confirmed adequate fixation and electrical testing confirmed stable parameters in all cases. All patients tolerated the procedure well without significant immediate complications. Conclusions We demonstrate the feasibility of transsubclavian implantation of the Aveir LCP.
Cardiac implantable electronic devices in female patients: Esthetic, breast implant, and anatomic considerations
Salinas, Cristina A., Mulpuru, Siva K. , Asirvatham, Samuel J. , Sharaf, Basel , Ezzeddine, Fatima , Mulpuru, Siva K , Asirvatham, Samuel J , Sharaf, Basel A, Sharaf, Basel A , Ezzeddine, Fatima M.

Journal of Cardiovascular Electrophysiology | February 15, 2024 | Volume: 35 | Issue: 4 | Pages: 747-761

10.1111/jce.16196 Get It

Abstract Introduction The implantation of a cardiac implantable electronic device (CIED) can have esthetic and psychological consequences on patients. We explore a heart team model for care coordination and discuss esthetic approaches for improved cosmetic outcomes in patients undergoing (CIED)‐related procedures or de novo implantation. Methods Patients undergoing CIED surgery for approved indications between June 2015 and June 2022 were identified. Patients were included when surgical care was provided by a collaborative relationship between the primary electrophysiologist and the plastic surgeon. Patient demographics, details of the surgical procedure, information on breast implants, complications, and outcomes related to cosmesis were recorded. Results Twenty‐two female patients were included in this study. The mean age was 50.2 ± 18.2 years. The mean follow‐up duration was 2.2 ± 5.5 months. The top two indications for the procedure included CIED generator change ( n = 9, 41%) and implantable cardioverter‐defibrillator (ICD) implantation ( n = 7, 32%). The most common reasons for involving plastic surgery in the procedure included surgery near breast implants ( n = 10, 45%) and device displacement or discomfort ( n = 8, 36%). CIED pocket position was prepectoral in 10 cases (45%), subpectoral in 11 patients (50%), and intramuscular in one patient (4.5%). The majority of the patients (20, 91%) had cosmetically acceptable results postprocedure. One patient (4.5%) had breast asymmetry on the CIED side, and another continued to have skin erosion over the CIED and leads. Conclusion A heart team approach incorporating the expertize of cardiac electrophysiology and plastic surgery is essential for providing optimal care for patients with breast implants and patients requesting esthetic appeal.
Ventricular arrhythmias in patients with prior aortic valve intervention: Characteristics, ablation and outcomes
Khalil, Fouad , Ahmad, Ali , Siontis, Konstantinos C. , Mulpuru, Siva K. , Munoz, Freddy Del‐Carpio , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Siontis, Konstantinos C , Mulpuru, Siva K , Del-Carpio Munoz, Freddy , Cha, Yong-Mei , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Khalil, Fouad , Toya, Takumi

Journal of Cardiovascular Electrophysiology | March 30, 2023 | Volume: 34 | Issue: 5 | Pages: 1206-1215

10.1111/jce.15896 Get It

AbstractIntroductionData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation in patients with aortic valve (AV) intervention (AVI) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of prosthetic valves. We sought to investigate the characteristics, safety, and outcomes of CA in patients with prior AVI and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior AVI (replacement or repair) who underwent CA for VT or PVC between 2013 and 2018. We investigated the mechanism of arrhythmia, ablation approach, perioperative complications, and outcomes.ResultsWe included 34 patients (88% men, mean age 64 ± 10.4 years, left ventricular (LV) ejection fraction 35.2 ± 15.0%) with prior AVI who underwent CA (22 VT; 12 PVC). LV access was obtained through trans‐septal approach in all patients except one patient who had percutaneous transapical access. One patient had combined retrograde aortic and trans‐septal approach. Scar‐related reentry was the dominant mechanism of induced VTs. Two patients had bundle branch reentry VTs. In the VT group, substrate mapping demonstrated heterogeneous scar that involved the peri‐AV area in 95%. Despite that, the site of successful ablation included the periaortic region only in 6 (27%) patients. In the PVC group, signal abnormalities consistent with scar in the periaortic area were noted in 4 (33%) patients. In 8 (67%) patients, the successful site of ablation was unrelated to the periaortic area. No procedure‐related complications occurred. The survival and recurrence‐free survival rate at 1 year tended to be lower in VT group than in PVC group (p = .06 and p = .05, respectively) with a 1‐year recurrence‐free survival rate of 52.8% and 91.7%, respectively. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with prior AVI.
Subcutaneous implantable cardioverter‐defibrillator noise following left ventricular assist device implantation
Khetarpal, Banveet Kaur , Javaid, Awad , Lee, Justin Z. , Mulpuru, Siva K. , Sorajja, Dan , Cha, Yong‐Mei , Mulpuru, Siva K , Kusumoto, Fred , Srivathsan, Komandoor

Journal of Arrhythmia | February 13, 2023 | Volume: 39 | Issue: 2 | Pages: 198-206

10.1002/joa3.12826 Get It

AbstractBackgroundThe incidence and impact of noise in a subcutaneous implantable cardioverter defibrillator (S‐ICD) after left ventricular assist device (LVAD) implantation is not well established.MethodsWe performed a retrospective study of patients implanted with LVAD and with a pre‐existing S‐ICD between January 2005 and December 2020 at the three Mayo Clinic centers (Minnesota, Arizona, and Florida).ResultsOf the 908 LVAD patients, a pre‐existing S‐ICD was present in 9 patients (mean age 49.1 ± 13.7 years, 66.7% males), 100% with Boston Scientific third‐generation EMBLEM MRI S‐ICD, 11% with HeartMate II (HM II), 44% with HeartMate 3 (HM 3), and 44% with HeartWare (HW) LVAD. The incidence of noise from LVAD‐related electromagnetic interference (EMI) was 33% and was only seen with HM 3 LVAD. Multiple measures attempted to resolve noise, including using alternative S‐ICD sensing vector, adjusting S‐ICD time zone, and increasing LVAD pump speed, were unsuccessful, necessitating S‐ICD device therapies to be turned off permanently.ConclusionsThe incidence of LVAD‐related S‐ICD noise is high in patients with concomitant LVAD and S‐ICD with significant impact on device function. As conservative management failed to resolve the EMI, the S‐ICDs had to be programmed off to avoid inappropriate shocks. This study highlights the importance of awareness of LVAD‐SICD device interference and the need to improve S‐ICD detection algorithms to eliminate noise.
Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery
Khalil, Fouad , Madhavan, Malini , Ahmad, Ali , Mulpuru, Siva K. , Siontis, Konstantinos C. , Deshmukh, Abhishek , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Madhavan, Malini , Kapa, Suraj , Mulpuru, Siva K , Siontis, Konstantinos C , Deshmukh, Abhishek J , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Khalil, Fouad , Toya, Takumi , Badawy, Mohamed, Kapa, Suraj , DeSimone, Christopher V.

Journal of Cardiovascular Electrophysiology | December 15, 2021 | Volume: 33 | Issue: 2 | Pages: 274-283

10.1111/jce.15331 Get It

AbstractBackgroundData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following mitral valve surgery (MVS) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves.ObjectiveTo investigate the characteristics, safety, and outcomes of radiofrequency CA in patients with prior MVS and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013 and December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri‐operative complications, and outcomes.ResultsIn our cohort, 31 patients (77% men, mean age 62.3 ± 10.8 years, left ventricular ejection fraction 39.2 ± 13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans‐septal approach in one patient. Heterogenous scar regions were present in 94% of VT patients and scar‐related reentry was the dominant mechanism of VT. Forty‐seven percent of PVC patients had abnormal substrate at the site targeted for ablation. Clinical VA substrates involved the peri‐mitral area in six patients with VT and five patients with PVC ablation. No procedure‐related complications were reported. The overall recurrence‐free rate at 1‐year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with MVS.
Catheter ablation of ventricular tachycardia in patients with postinfarction left ventricular aneurysm
Amin, Mustapha, Hilaire, Emilie, Siontis, Konstantinos C. , Madhavan, Malini , Mulpuru, Siva K. , Deshmukh, Abhishek , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Farwati, Medhat , Siontis, Konstantinos C , Madhavan, Malini , Kapa, Suraj , Mulpuru, Siva K , Deshmukh, Abhishek J , Cha, Yong-Mei , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Kapa, Suraj

Journal of Cardiovascular Electrophysiology | October 20, 2021 | Volume: 32 | Issue: 12 | Pages: 3156-3164

10.1111/jce.15273 Get It

AbstractBackgroundWhile ventricular tachycardia (VT) in the setting of postmyocardial infarction left ventricular aneurysms (LVA) is not uncommonly encountered, there is a scarcity of data regarding the safety, efficacy, and outcomes of ablation of VT in this subset of patients.MethodsOur study included consecutive patients aged 18 years or older with postmyocardial infarction LVA who presented to Mayo Clinic for catheter ablation of VT between 2002 and 2018.ResultsOf 34 patients, the mean age was 70.4 ± 9.1 years; 91% were male. Mean LVEF was 29 ± 9.7% and left ventricular end‐diastolic dimension was 64.9 ± 6.6 mm. The site of the LVA was apical in 21 patients (62%). Fifteen patients (44%) presented with electrical storm or incessant VT. Nine patients (26%) had a history of intracardiac thrombus. All except for one patient had at least one VT originating from the aneurysm. The mean number of VTs was 2.9 ± 1.7. All patients underwent ablation at the site of the aneurysm. Ablation outside the aneurysm was performed in 13 patients (38%). Low‐voltage fractionated potentials and/or late potentials at the aneurysmal site were present in all cases. Complete elimination of all VTs was achieved in 18 (53%), while the elimination of the clinical VT with continued inducibility of nonclinical VTs was achieved in a further 11 patients (32%). Two patients developed cardiac tamponade requiring pericardiocentesis. During a mean follow‐up period of 2.3 ± 2.4 years, 11 patients (32%) experienced VT recurrence. Freedom from all‐cause mortality at 1‐year follow‐up was 94%.ConclusionRadiofrequency catheter ablation targeting the aneurysmal site is a feasible and reasonably effective management strategy for clinical VTs in patients with postinfarction LVA.