Digital twin creation of a proton therapy treatment environment with hybrid LiDAR and RGB 3D camera
Dougherty, Jingjing M. , Tryggestad, E., Beltran, Chris , Tryggestad, Erik J, Beltran, Chris J , Dougherty, Jingjing M

Journal of Applied Clinical Medical Physics | August 16, 2025 | Volume: 26 | Issue: 8 | Pages: No page available

10.1002/acm2.70231 Get It

AbstractIntroductionThis study evaluates the feasibility of utilizing a commercial‐grade 3D LiDAR/RGB camera, combined with 3D reconstruction software, to create an accurate and hyper‐realistic digital model of a proton therapy treatment room. This reconstructed model aims to enhance collision avoidance strategies and improve 3D machine model accessibility. Utilization of a 3D LiDAR/RGB camera as a radiotherapy environment modeling has not been reported prior.MethodsTo create a comprehensive 3D model of a half‐gantry proton therapy system, colored point cloud data was captured using the Matterport Pro 3 camera, a hybrid LiDAR and RGB imaging system with high‐resolution capabilities (134.2 MP), a 360° horizontal field of view, and 20 mm accuracy at 10 m. A total of 117 acquisition points, distributed across the treatment room with three camera heights, ensured complete coverage and minimal occlusions. Scanning, completed in under 3 hours, was monitored in real time using the Matterport App. Post‐scan processing involved denoising and converting the point cloud into 3D mesh structures using MeshLab, followed by refined pair‐wise iterative closest point (ICP) alignments. Textures and materials were assigned to reflect real‐world objects, and a ray‐tracing engine simulated realistic lighting in Blender. Animations illustrating the kinematics of the treatment couch and gantry were simulated in Blender for enhanced visualization.ResultsThe scanning process achieved complete data capture without missing information, attributed to strategic oversampling during data acquisition. The mean root mean square error (RMSE) of the ICP registration was 0.008 m. The validation process confirmed that the dimensions of the treatment couch within the digital model closely matched the actual measurements with less than 2 cm deviation, indicating high accuracy. The resulting digital twin provided a photorealistic and immersive representation of the proton therapy treatment room, serving as a valuable digital asset for various applications.ConclusionIt is possible to generate vendor‐independent and highly accurate 3D models of the proton treatment room environment with a commercial grade LiDAR/RGB camera to expand future research opportunities and education endeavors.
Enhancing proton therapy quality assurance with custom‐designed Octopoint phantom and Gafchromic film
Tang, Xueyan , Beltran, Chris , Furutani, Keith M. , Gilson, Glen, Gustafson, Jon M., Herman, Michael , Johnson, J. , Kruse, Jon J. , Long, Kenneth M., Mundy, Daniel W. , Remmes, Nicholas B. , Tasson, A , Whitaker, Todd , Matysiak, Witold, Tryggestad, E., Matysiak, W , Gilson, Graham S, Gustafson, Jon, Ito, Shima, Johnson, Jed E , Tasson, Alexandria , Whitaker, Thomas J , Tryggestad, Erik J, Beltran, Chris J , Furutani, Keith M , Matysiak, Witold P , Ito, Shima , Long, Kenneth M.

Journal of Applied Clinical Medical Physics | July 14, 2025 | Volume: 26 | Issue: 7 | Pages: No page available

10.1002/acm2.70156 Get It

Abstract Background Proton therapy offers precise tumor targeting while minimizing damage to surrounding healthy tissue, making it especially valuable for treating tumors near critical organs and in pediatric patients. However, its success depends on accurate beam delivery, requiring rigorous quality assurance (QA) to maintain treatment precision and effectiveness. Purpose This study aims to standardize the measurement of key aspects of proton therapy delivery, such as gantry and couch isocentricity, spot position accuracy, and spot size consistency. The goal is to enhance the delivery accuracy of proton therapy across various clinical settings, improving patient outcomes. Methods The QA framework uses the Octopoint phantom, Gafchromic film, and spot position monitor (SPM) log data to evaluate proton beam isocentricity, spot position, and spot size. The Octopoint phantom, made from acrylic, was used with Gafchromic films at various gantry and couch angles to measure isocentricity. MATLAB tools were used to analyze spot positions, and SPM logs provided verification. Sensitivity tests were conducted to assess the system's response to intentional shifts and errors, ensuring alignment with clinical QA standards. Results The Octopoint phantom's stepwise two‐dimensional (2D) fitting process, validated against film‐measured dose profiles, accurately identified beam and ball bearing (BB) centroid locations. Isocentricity tests conducted over 8 months across four gantries demonstrated consistent beam‐to‐BB radial offsets. The phantom showed excellent repeatability, with a maximum standard deviation of 0.1 mm across various couch‐gantry combinations. Sensitivity testing across all axes revealed a strong alignment between intended shifts and measured values. Over the course of a year, film measurements tracked spot position and size consistency, with deviations remaining within acceptable clinical limits. Comparisons with SPM data further confirmed the system's reliability in maintaining beam accuracy across different gantry angles and energy levels. Conclusions This study presents a reliable QA framework for ensuring precision in proton therapy delivery. By combining the Octopoint phantom, Gafchromic film analysis, and SPM log file evaluation, we effectively measured isocentricity, spot position accuracy, and spot size stability. The framework demonstrated adaptability across various clinical QA tasks, enhancing the accuracy and safety of proton therapy treatments.
The impact of therapeutic radiation on drug distribution across the blood-brain barrier in normal mouse brain and orthotopic glioblastoma tumors
Oberoi, Rajneet K. , Oh, Ju‐Hee , Decker, Paul A. , Sio, Terence T., Wilson, Zachary C, Connors, Margaret A. , Carlson, Brett L. , Ott, Lauren L. , Tryggestad, E., Passow, Jeanette E. Eckel, Elmquist, William F. , Sarkaria, Jann N. , Decker, Paul A. , Tryggestad, Erik J, Eckel Passow, Jeanette E, Sarkaria, Jann N , Zhang, Wenjuan , Grams, Michael P. , Talele, Surabhi , Wilson, Zachary C, Bakken, Katrina K. , Burgenske, Danielle M.

Neuro-Oncology | March 31, 2025 | Volume: 27 | Issue: 9 | Pages: 2250-2261

10.1093/neuonc/noaf093 Get It

Abstract Background Most oncology therapeutics have limited distribution into the brain, and developing strategies to overcome this limitation would be clinically impactful. While therapeutic radiation is often cited as a strategy to accomplish this, there are no published studies demonstrating the effect of radiation on drug distribution into the brain or brain tumors. Methods Mice were treated with brain radiation (6 Gy × 5, 4 Gy × 10; 40 Gy × 1) and dosed with drugs (levetiracetam, cefazolin, nedisertib, brigimadlin, apitolisib, or GNE-317) at times ranging from just prior to months after radiation. Plasma and tissue drug concentrations were measured by LC-MS/MS. Results Radiation did not significantly enhance drug delivery into brain tissue for levetiracetam, cefazolin, GNE-317, apitolisib, or nedisertib at any time post-radiation. Even a single, supra-therapeutic dose of radiation (40 Gy) did not significantly affect brain distribution of GNE-317 or apitolisib (P ≥ .07) from 16 to 160 hours post-radiation. For brigimadlin, radiation (6 Gy × 5) was associated with a modest but significant increase in drug accumulation only at 72 hours post-radiation (brain-to-plasma ratio 0.014 ± 0.006 vs. 0.025 ± 0.010, respectively; P = .04), but not at any other timepoint (24 hours, 15, 28, 94, 133, 183 days; P > .05). Similarly, radiation (6 Gy × 5) of orthotopic tumors did not increase levels of brigimadlin in GBM10 or GBM108 or nedisertib in GBM108 (P > .05). Conclusions Radiation had no meaningful impact on drug delivery into brain or brain tumors for the drugs tested.
Evaluation of a New, Highly Flexible Radiofrequency Coil for MR Simulation of Patients Undergoing External Beam Radiation Therapy
McGee, Kiaran P. , Campeau, Norbert G. , Witte, Robert J. , Rossman, Philip J., Christopherson, Jackie A., Tryggestad, E., Brinkmann, Debra H. , Daniel, J., Park, Sean S. , Rettmann, Dan , Robb, Fraser , Tryggestad, Erik J, Rettmann, Dan W , Campeau, Norbert G , McGee, Kiaran , Park, Sean S , Ma, Daniel J.

Journal of Clinical Medicine | October 11, 2022 | Volume: 11 | Issue: 20 | Pages: 5984

10.3390/jcm11205984 Get It

Purpose: To evaluate the performance of a new, highly flexible radiofrequency (RF) coil system for imaging patients undergoing MR simulation. Methods: Volumetric phantom and in vivo images were acquired with a commercially available and prototype RF coil set. Phantom evaluation was performed using a silicone-filled humanoid phantom of the head and shoulders. In vivo assessment was performed in five healthy and six patient subjects. Phantom data included T1-weighted volumetric imaging, while in vivo acquisitions included both T1- and T2-weighted volumetric imaging. Signal to noise ratio (SNR) and uniformity metrics were calculated in the phantom data, while SNR values were calculated in vivo. Statistical significance was tested by means of a non-parametric analysis of variance test. Results: At a threshold of p = 0.05, differences in measured SNR distributions within the entire phantom volume were statistically different in two of the three paired coil set comparisons. Differences in per slice average SNR between the two coil sets were all statistically significant, as well as differences in per slice image uniformity. For patients, SNRs within the entire imaging volume were statistically significantly different in four of the nine comparisons and seven of the nine comparisons performed on the per slice average SNR values. For healthy subjects, SNRs within the entire imaging volume were statistically significantly different in seven of the nine comparisons and eight of the nine comparisons when per slice average SNR was tested. Conclusions: Phantom and in vivo results demonstrate that image quality obtained from the novel flexible RF coil set was similar or improved over the conventional coil system. The results also demonstrate that image quality is impacted by the specific coil configurations used for imaging and should be matched appropriately to the anatomic site imaged to ensure optimal and reproducible image quality.
Characterization and commissioning of a Leksell Gamma Knife ICON system for framed and frameless stereotactic radiosurgery
Hu, Yue‐Houng , Hickling, Susannah , Qian, J. , Blackwell, C. Robert, McLemore, Luke B., Tryggestad, E., Hickling, Susannah V, Qian, Jing , Tryggestad, Erik J, Qian, Jing

Journal of Applied Clinical Medical Physics | January 22, 2022 | Volume: 23 | Issue: 3 | Pages: No page available

10.1002/acm2.13475 Get It

AbstractPurposeThe Leksell Gamma Knife Icon unit (IU) was introduced recently as an upgrade to the Perfexion unit (PU) at our Gamma Knife practice. In the current study, we sought mainly to characterize dosimetry and targeting accuracy of the IU treatment deliveries using both invasive frame and frameless treatment workflows.MethodsRelative output factors were measured by delivering single‐shot 4, 8 and 16 mm radiation profiles in the manufacturer's acrylonitrile butadiene styrene spherical phantom in coronal and sagittal planes using EBT3 film. Resultant dosimetry was compared with the manufacturer's dose calculation and derived output factors were compared with the manufacturer's published value. Geometric consistency of stereotactic coordinates based on cone‐beam computed tomography (CBCT) versus the traditional conventional CT‐based method was characterized using a rigid phantom containing nine fiducial indicators over four separate trials. End‐to‐end (E2E) testing using EBT3 film was designed to evaluate both dosimetric and geometric accuracy for hypothetical framed and frameless workflows.ResultsRelative output factors as measured by the manufacturer were independently confirmed using EBT3 film measurements to within 2%. The mean 3D radial discrepancy in stereotactic space between CBCT and CT‐based definition over the sampled locations in our rigid geometry phantom was demonstrated to be between 0.40 mm and 0.56 mm over the set of trials, larger than prior reported values. E2E performed in 2D demonstrates sub‐mm (and typically < 0.5 mm) accuracy for framed and frameless workflows; geometric accuracy of framed treatments using CBCT‐defined stereotactic coordinates was shown to be slightly improved in comparison with those defined using conventional CT. Furthermore, in phantom, frameless workflows exhibited better accuracy than framed workflows for fractionated treatments, despite large magnitudes of introduced interfraction setup error. Accuracy of dosimetric delivery was confirmed in terms of qualitative comparisons of dose profiles and in terms of 2D gamma pass rates based on 1%/1 mm criteria.ConclusionThe IU was commissioned for clinical use of frameless and framed treatment protocols. The present study outlines an extensive E2E methodology for confirmation of dosimetric and geometric treatment accuracy.
Design of a 3D patient‐specific collision avoidance virtual framework for half‐gantry proton therapy system
Dougherty, Jingjing M. , Whitaker, Thomas J. , Mundy, Daniel W. , Tryggestad, E., Beltran, Chris , Tryggestad, Erik J, Beltran, Chris J., Beltran, Chris J

Journal of Applied Clinical Medical Physics | December 10, 2021 | Volume: 23 | Issue: 2 | Pages: No page available

10.1002/acm2.13496 Get It

AbstractIntroductionThis study presents a comprehensive collision avoidance framework based on three‐dimension (3D) computer‐aided design (CAD) modeling, a graphical user interface (GUI) as peripheral to the radiation treatment planning (RTP) environment, and patient‐specific plan parameters for intensity‐modulated proton therapy (IMPT).MethodsA stand‐alone software application was developed leveraging the Varian scripting application programming interface (API) for RTP database object accessibility. The Collision Avoider software models the Hitachi ProBeat‐V half gantry design and the Kuka robotic couch with triangle mesh structures. Patient‐specific plan parameters are displayed in the collision avoidance software for potential proximity evaluation. The external surfaces of the patients and the immobilization devices are contoured based on computed tomography (CT) images. A “table junction‐to‐CT‐origin” (JCT) measurement is made for every patient at the time of CT simulation to accurately provide reference location of the patient contours to the treatment couch. Collision evaluations were performed virtually with the program during treatment planning to prevent four major types of collisional events: collisions between the gantry head and the treatment couch, gantry head and the patient's body, gantry head and the robotic arm, and collisions between the gantry head and the immobilization devices.ResultsThe Collision Avoider software was able to accurately model the proton treatment delivery system and the robotic couch position. Commonly employed clinical beam configuration and JCT values were investigated. Brain and head and neck patients require more complex gantry and patient positioning system configurations. Physical measurements were performed to validate 3D CAD model geometry. Twelve clinical proton treatment plans were used to validate the accuracy of the software. The software can predict all four types of collisional events in our clinic since its full implementation in 2020.ConclusionA highly efficient patient‐specific collision prevention program for scanning proton therapy has been successfully implemented. The graphical program has provided accurate collision detection since its inception at our institution.
Phase II Evaluation of Stereotactic Ablative Radiotherapy (SABR) and Immunity in 11C-Choline-PET/CT–Identified Oligometastatic Castration-Resistant Prostate Cancer
Zhang, Henan , Orme, Jacob J. , Abraha, Feven , Stish, Bradley J. , Lowe, Val J. , Tryggestad, E., Bold, Michael S., Pagliaro, Lance C. , Choo, C. Richard, Brinkmann, Debra H. , Iott, Matthew J., Quevedo, J. Fernando , Harmsen, William S. , Costello, Brian A. , Johnson, Geoffrey B. , Nathan, Mark A., Olivier, Kenneth R. , Pisansky, Thomas M. , Kwon, Eugene D., Tryggestad, Erik J, Brinkmann, Debra H , Davis, Brian J. , Costello, Brian A , Johnson, Geoffrey B , Dong, Haidong , Park, Sean S , Lucien, Fabrice , Dong, Haidong , Park, Sean S.

Clinical Cancer Research | September 30, 2021 | Volume: 27 | Issue: 23 | Pages: 6376-6383

10.1158/1078-0432.ccr-21-2510 Get It

Abstract Purpose: Outcomes for resistant metastatic castration-resistant prostate cancer (CRPC) are poor. Stereotactic ablative radiotherapy (SABR) induces antitumor immunity in clinical and preclinical studies, but immunologic biomarkers are lacking. Patients and Methods: Eighty-nine patients with oligometastatic CRPC were identified by 11C-Choline-PET (Choline-PET) from August 2016 to December 2019 and treated with SABR. Prespecified coprimary endpoints were 2-year overall survival (OS) and PSA progression. Secondary endpoints included 2-year SABR-treated local failure and 6-month adverse events. Correlative studies included peripheral blood T-cell subpopulations before and after SABR. Results: 128 lesions in 89 patients were included in this analysis. Median OS was 29.3 months, and 1- and 2-year OS were 96% and 80%, respectively. PSA PFS was 40% at 1 year and 21% at 2 years. Local PFS was 84.4% and 75.3% at 1 and 2 years, respectively, and no grade ≥3 AEs were observed. Baseline high levels of tumor-reactive T cells (TTR; CD8+CD11ahigh) predicted superior local, PSA, and distant PFS. Baseline high levels of effector memory T cells (TEM; CCR7−CD45RA−) were associated with improved PSA PFS. An increase in TTR at day 14 from baseline was associated with superior OS. Conclusions: This is the first comprehensive effector T-cell immunophenotype analysis in a phase II trial before and after SABR in CRPC. Results are favorable and support the incorporation of immune-based markers in the design of future randomized trials in patients with oligometastatic CRPC treated with SABR.
Low-Dose Image-Guided Pediatric CNS Radiation Therapy: Final Analysis From a Prospective Low-Dose Cone-Beam CT Protocol From a Multinational Pediatrics Consortium
Alcorn, Sara R. , Zhou, Xian Chiong, Bojechko, C., Rubo, Rodrigo A., Chen, Michael , Dieckmann, Karin , Ford, Eric C., Kobyzeva, Daria , MacDonald, Shannon M. , McNutt, Todd , Nechesnyuk, А. V. , Nilsson, Kristina , Sjostrand, Hakan, Smith, Koren, Stock, Markus , Tryggestad, E., Villar, Rosângela Correa , Winey, Brian , Terezakis, Stephanie , Tryggestad, Erik J, Terezakis, Stephanie A , Ermoian, Ralph P.

Technology in Cancer Research & Treatment | April 24, 2020 | Volume: 19 | Issue: No issue available | Pages: No page available

10.1177/1533033820920650 Get It

Background: Lower-dose cone-beam computed tomography protocols for image-guided radiotherapy may permit target localization while minimizing radiation exposure. We prospectively evaluated a lower-dose cone-beam protocol for central nervous system image-guided radiotherapy across a multinational pediatrics consortium. Methods: Seven institutions prospectively employed a lower-dose cone-beam computed tomography central nervous system protocol (weighted average dose 0.7 mGy) for patients ≤21 years. Treatment table shifts between setup with surface lasers versus cone-beam computed tomography were used to approximate setup accuracy, and vector magnitudes for these shifts were calculated. Setup group mean, interpatient, interinstitution, and random error were estimated, and clinical factors were compared by mixed linear modeling. Results: Among 96 patients, with 2179 pretreatment cone-beam computed tomography acquisitions, median age was 9 years (1-20). Setup parameters were 3.13, 3.02, 1.64, and 1.48 mm for vector magnitude group mean, interpatient, interinstitution, and random error, respectively. On multivariable analysis, there were no significant differences in mean vector magnitude by age, gender, performance status, target location, extent of resection, chemotherapy, or steroid or anesthesia use. Providers rated >99% of images as adequate or better for target localization. Conclusions: A lower-dose cone-beam computed tomography protocol demonstrated table shift vector magnitude that approximate clinical target volume/planning target volume expansions used in central nervous system radiotherapy. There were no significant clinical predictors of setup accuracy identified, supporting use of this lower-dose cone-beam computed tomography protocol across a diverse pediatric population with brain tumors.
Imaging and Dosimetry Study of Inter-fraction Setup Error in a Murine Xenograft Flank Tumor Radiation Model
Smith, Emily J. , Tryggestad, E., Carlson, Brett L. , Walb, Matthew C., Tryggestad, Erik J, Sarkaria, Jann N.

Radiation Research | December 26, 2019 | Volume: 193 | Issue: 2 | Pages: 161

10.1667/rr15526.1 Get It