Back to Authors

Winey, Brian

https://orcid.org/0000-0002-3894-3755

Mayo Clinic

Massachusetts General Hospital

Citations 2

Low-Dose Image-Guided Pediatric CNS Radiation Therapy: Final Analysis From a Prospective Low-Dose Cone-Beam CT Protocol From a Multinational Pediatrics Consortium
Alcorn, Sara R. , Zhou, Xian Chiong, Bojechko, C., Rubo, Rodrigo A., Chen, Michael , Dieckmann, Karin , Ford, Eric C., Kobyzeva, Daria , MacDonald, Shannon M. , McNutt, Todd , Nechesnyuk, А. V. , Nilsson, Kristina , Sjostrand, Hakan, Smith, Koren, Stock, Markus , Tryggestad, E., Villar, Rosângela Correa , Winey, Brian , Terezakis, Stephanie , Tryggestad, Erik J, Terezakis, Stephanie A , Ermoian, Ralph P.

Technology in Cancer Research & Treatment | April 24, 2020 | Volume: 19 | Issue: No issue available | Pages: No page available

10.1177/1533033820920650 Get It

Background: Lower-dose cone-beam computed tomography protocols for image-guided radiotherapy may permit target localization while minimizing radiation exposure. We prospectively evaluated a lower-dose cone-beam protocol for central nervous system image-guided radiotherapy across a multinational pediatrics consortium. Methods: Seven institutions prospectively employed a lower-dose cone-beam computed tomography central nervous system protocol (weighted average dose 0.7 mGy) for patients ≤21 years. Treatment table shifts between setup with surface lasers versus cone-beam computed tomography were used to approximate setup accuracy, and vector magnitudes for these shifts were calculated. Setup group mean, interpatient, interinstitution, and random error were estimated, and clinical factors were compared by mixed linear modeling. Results: Among 96 patients, with 2179 pretreatment cone-beam computed tomography acquisitions, median age was 9 years (1-20). Setup parameters were 3.13, 3.02, 1.64, and 1.48 mm for vector magnitude group mean, interpatient, interinstitution, and random error, respectively. On multivariable analysis, there were no significant differences in mean vector magnitude by age, gender, performance status, target location, extent of resection, chemotherapy, or steroid or anesthesia use. Providers rated >99% of images as adequate or better for target localization. Conclusions: A lower-dose cone-beam computed tomography protocol demonstrated table shift vector magnitude that approximate clinical target volume/planning target volume expansions used in central nervous system radiotherapy. There were no significant clinical predictors of setup accuracy identified, supporting use of this lower-dose cone-beam computed tomography protocol across a diverse pediatric population with brain tumors.
Using four‐dimensional computed tomography images to optimize the internal target volume when using volume‐modulated arc therapy to treat moving targets
Yakoumakis, N., Winey, Brian , Killoran, Joseph H., Mayo, Charles S. , Niedermayr, Thomas, Panayiotakis, George , Lingos, Tania, Court, Laurence E. , Mayo, Charles S.

Journal of Applied Clinical Medical Physics | February 27, 2017 | Volume: 13 | Issue: 6 | Pages: 181-188

10.1120/jacmp.v13i6.3850 Get It

In this work we used 4D dose calculations, which include the effects of shape deformations, to investigate an alternative approach to creating the ITV. We hypothesized that instead of needing images from all the breathing phases in the 4D CT dataset to create the outer envelope used for treatment planning, it is possible to exclude images from the phases closest to the inhale phase. We used 4D CT images from 10 patients with lung cancer. For each patient, we drew a gross tumor volume on the exhale‐phase image and propagated this to the images from other phases in the 4D CT dataset using commercial image registration software. We created four different ITVs using the N phases closest to the exhale phase (where , 8, 7, 6). For each ITV contour, we created a volume‐modulated arc therapy plan on the exhale‐phase CT and normalized it so that the prescribed dose covered at least 95% of the ITV. Each plan was applied to CT images from each CT phase (phases 1–10), and the calculated doses were then mapped to the exhale phase using deformable registration. The effect of the motion was quantified using the dose to 95% of the target on the exhale phase and tumor control probability. For the three‐dimensional and 4D dose calculations of the plan where , differences in the value varied from 3% to 14%, with an average difference of 7%. For 9 of the 10 patients, the reduction in was less than 5% if eight phases were used to create the ITV. For three of the 10 patients, the reduction in the was less than 5% if seven phases were used to create the ITV. We were unsuccessful in creating a general rule that could be used to create the ITV. Some reduction (8/10 phases) was possible for most, but not all, of the patients, and the ITV reduction was small.PACS number: 87.55.D‐