The effect of common dental fixtures on treatment planning and delivery for head and neck intensity modulated proton therapy
Hu, Yue‐Houng , Seum, Wan Chan Tseung Hok, Muller, Olivia M. , Foote, Robert L. , Mundy, Daniel W. , Hunzeker, Ashley, Muller, Olivia, Hunzeker, Ashley E.

Journal of Applied Clinical Medical Physics | March 27, 2023 | Volume: 24 | Issue: 7 | Pages: No page available

10.1002/acm2.13973 Get It

AbstractPurposeProton treatment plan perturbation by common dental fixtures such as amalgams (Am) and porcelain‐fused‐to‐metal (PFM) crowns has, to date, been uncharacterized. Previous studies have been conducted to determine the physical effect of these materials within the beam path for single spots, but their effects on complex treatment plans and clinical anatomy have not yet been quantified. The present manuscript aims to study the effect of Am and PFM fixtures on proton treatment planning in a clinical setting.MethodsAn anthropomorphic phantom with removable tongue, maxilla, and mandible modules was simulated on a clinical computed tomography (CT) scanner. Spare maxilla modules were modified to include either a 1.5 mm depth central groove occlusal amalgam (Am) or a porcelain‐fused‐to‐metal (PFM) crown, implanted on the first right molar. Modified tongue modules were 3D printed to accommodate several axial or sagittal oriented pieces of EBT‐3 film. Clinically representative spot‐scanning proton plans were generated in Eclipse v.15.6 using the proton convolution superposition (PCS) algorithm v.15.6.06 using a multi‐field optimization (MFO) technique with the goal of delivering a uniform 54 Gy dose to a clinical target volume (CTV) typical of a base‐of‐tongue (BoT) treatment. A typical geometric beam arrangement of two anterior oblique (AO) beams and a posterior beam was employed. Plans optimized without any material overrides were delivered to the phantom A) without implants; B) with Am fixture; or C) with PFM crown. Plans were also reoptimized and delivered with inclusion of material overrides to equate relative stopping power of the fixture with that of a previously measured result.ResultsPlans exhibit slightly greater dose weight towards AO beams. The optimizer accounted for inclusion of fixture overrides by increasing beam weights to the beam closest to the implant. Film measurements exhibited cold spots directly within the beam path through the fixture in plans with and without overridden materials. Cold spots were somewhat mitigated in plans including overridden materials in the structure set but were not entirely eliminated. Cold spots associated with Am and PFM fixtures were quantified at 17% and 14% for plans without overrides, respectively, and 11% and 9% with using Monte Carlo simulation. Compared with film measurements and Monte Carlo simulation, the treatment planning system underestimates the dose shadowing effect in plans including material overrides.ConclusionsDental fixtures create a dose shadowing effect directly in line with the beam path through the material. This cold spot is partially mitigated by overriding the material to measured relative stopping powers. Due to uncertainties in modeling perturbation through the fixture, the magnitude of the cold spot is underestimated using the institutional TPS when compared to measurement and MC simulation.
Physical characterization of therapeutic proton delivery through common dental materials
Hu, Yue‐Houng , Tseung, Hok Seum Wan Chan, Mundy, Daniel W. , Wan Chan Tseung, Hok Seum

Medical Physics | March 12, 2022 | Volume: 49 | Issue: 5 | Pages: 2904-2913

10.1002/mp.15602 Get It

AbstractPurposeDental fixtures are commonplace in an aging, radiation treatment population. The current, local standard of practice in particle therapy is to employ treatment geometries to avoid delivery through implanted dental fixtures. The present study aims to observe the physical effect of delivering therapeutic proton beams through common dental fixture materials as prelude to an eventual goal of assessing the feasibility of using treatment geometries not specified for avoidance of oral implants. A sampling of common dental materials was selected based on prosthodontic consult and was evaluated in terms of relative stopping power and three‐dimensional (3D) dose perturbation.MethodsAmalgams, porcelain‐fused‐to‐metal (PFM) crowns consisting of zirconia and non‐noble base metals, and lithium disilicate implants were chosen for analysis. Theoretical stopping power (S) and mass stopping power (S/ρ) were calculated using the Stopping and Range of Ions in Matter (SRIM) application, basing stoichiometric compositions of each fixture on published materials data. S and S/ρ were calculated for a range of historically available compositions of amalgams from 1900 until the current era. The perturbance of S and S/ρ as a function of clinically relevant ranges of amalgam compositions for the modern era was analyzed. Water equivalent thickness (WET) and relative stopping power (Srel) of each material was measured for a clinical spot‐scanning proton beam with monoenergies of 159.9 and 228.8 MeV with a multi‐layer ionization chamber (MLIC). Subsequently, 3D dose perturbation was assessed by delivering proton beams through a custom phantom designed to simulate both en‐face and on‐edge treatment geometries through the selected materials. A treatment plan mimicking the experimental delivery was constructed in the institutional treatment planning system and calculated using TOPAS‐based Monte Carlo simulation (MCS). Experimental results were used to validate the MCS. Finally, treatment planning system (TPS) outputs were compared to MCS to determine the accuracy of the dose calculation model.ResultsHistorical compositions of amalgams ranged in S from 44.8 to 42.9 MeV/cm, with the greatest deviation being observed for the 1900–1959 era. Deviation as a function of amalgam composition from the modern era was most sensitive to proportion of Hg, accounting for deviations up to ‐4.2% at the greatest clinically relevant concentration. S/ρ was not found to vary greatly between each porcelain and metal alloy material for PFM type crowns. Relative stopping powers ranged between 1.3 and 5.4 for all studied materials, suggesting substantial changes in proton range with respect to water. Film measurements of pristine spots confirm dose perturbance and shortening of proton range, with an upstream shift of each Bragg peak being observed directly behind the installed fixture. At high energies, cold spots were found in all cases directly behind each material feature with a medial fill‐in of dose occurring distally. Qualitative agreement of spot perturbance was confirmed between film measurements and MCS. Finally, when comparing integrated depth doses (IDD) by summing over all axial directions, good agreement is observed between TPS and MCS.ConclusionsAll dental materials studied substantially perturbed the dosimetry of pristine proton spots both in terms of WET/Srel as well as the spatial distribution of dose. Proton range was quantifiably shortened, and each dental material affected a cold spot directly behind the object with medial dose back‐filling was observed distally. MCS and Eclipse dose calculations exhibited good agreement with measurements, suggesting that treatment planning without employing avoidance strategies may be possible with further investigation.
Characterization and commissioning of a Leksell Gamma Knife ICON system for framed and frameless stereotactic radiosurgery
Hu, Yue‐Houng , Hickling, Susannah , Qian, J. , Blackwell, C. Robert, McLemore, Luke B., Tryggestad, E., Hickling, Susannah V, Qian, Jing , Tryggestad, Erik J, Qian, Jing

Journal of Applied Clinical Medical Physics | January 22, 2022 | Volume: 23 | Issue: 3 | Pages: No page available

10.1002/acm2.13475 Get It

AbstractPurposeThe Leksell Gamma Knife Icon unit (IU) was introduced recently as an upgrade to the Perfexion unit (PU) at our Gamma Knife practice. In the current study, we sought mainly to characterize dosimetry and targeting accuracy of the IU treatment deliveries using both invasive frame and frameless treatment workflows.MethodsRelative output factors were measured by delivering single‐shot 4, 8 and 16 mm radiation profiles in the manufacturer's acrylonitrile butadiene styrene spherical phantom in coronal and sagittal planes using EBT3 film. Resultant dosimetry was compared with the manufacturer's dose calculation and derived output factors were compared with the manufacturer's published value. Geometric consistency of stereotactic coordinates based on cone‐beam computed tomography (CBCT) versus the traditional conventional CT‐based method was characterized using a rigid phantom containing nine fiducial indicators over four separate trials. End‐to‐end (E2E) testing using EBT3 film was designed to evaluate both dosimetric and geometric accuracy for hypothetical framed and frameless workflows.ResultsRelative output factors as measured by the manufacturer were independently confirmed using EBT3 film measurements to within 2%. The mean 3D radial discrepancy in stereotactic space between CBCT and CT‐based definition over the sampled locations in our rigid geometry phantom was demonstrated to be between 0.40 mm and 0.56 mm over the set of trials, larger than prior reported values. E2E performed in 2D demonstrates sub‐mm (and typically < 0.5 mm) accuracy for framed and frameless workflows; geometric accuracy of framed treatments using CBCT‐defined stereotactic coordinates was shown to be slightly improved in comparison with those defined using conventional CT. Furthermore, in phantom, frameless workflows exhibited better accuracy than framed workflows for fractionated treatments, despite large magnitudes of introduced interfraction setup error. Accuracy of dosimetric delivery was confirmed in terms of qualitative comparisons of dose profiles and in terms of 2D gamma pass rates based on 1%/1 mm criteria.ConclusionThe IU was commissioned for clinical use of frameless and framed treatment protocols. The present study outlines an extensive E2E methodology for confirmation of dosimetric and geometric treatment accuracy.