Design and commissioning of divergent proton minibeam collimators and supporting accessories for homogeneous target dose irradiation
Hara, Daiki , Ma, Jiasen , Corner, Stephen, Mutter, Robert W. , Remmes, Nicholas, Tseung, Hok Seum Wan Chan, Hara, D , Corner, S M , Tseung, H Wan Chan , Grams, Michael P. , Remmes, Nicholas B.

Physics in Medicine & Biology | August 5, 2026 | Volume: 71 | Issue: 17 | Pages: 175039

10.1088/1361-6560/ae95d4 Get It

Abstract Objective. Proton minibeam radiation therapy (pMBRT) is a novel spatially fractionated radiation therapy technique that offers improved tumor control and reduced normal tissue toxicity. However, its clinical translation has been hindered in part by limited field sizes, low dose rates, and complex manufacturing. This work describes the design, manufacturing, and commissioning of a novel divergent pMBRT collimator along with accessory components to maximize its versatility and facilitate clinical implementation. Approach. The dosimetric outcomes for pMBRT collimator geometry, including slit width, center-to-center (CTC) spacing, thickness, divergence, and field size, were evaluated using TOPAS Monte Carlo (MC) to maximize surface peak-to-valley dose ratio (PVDR) while maintaining uniform target coverage. The collimator was constructed using brass plates held by aluminum side holders. Commissioning measurements with a PTW Bragg peak chamber and EBT4 radiochromic film were compared to TOPAS and an in-house fast GPU-based MC simulation. Ancillary equipment consisting of lead foils, range shifters, custom apertures, and secondary pMBRT collimators were characterized in tandem. Main results. An optimized divergent pMBRT collimator with 0.5 mm slit width, 2.0 mm CTC distance, and 40 mm thickness produced a surface PVDR of 4.8 while preserving quasi-homogeneous dose in the 6–14 cm depth region. Measured dose profiles demonstrated valley dose agreement within 3% for both TOPAS and GPU-based MC predictions after the simulated collimator geometry was refined to match Bragg-peak chamber average dose measurements. The onset of the quasi-homogeneous dose region was shifted toward shallower depths by using thin lead foils, without significantly impacting entrance PVDR. Apertures sharpened penumbra and enhanced peripheral PVDR. A dual collimator approach produced 2D pinhole dose arrays that resulted in valley doses from MC simulations and film measurements agreeing within ∼5%. Significance. We demonstrated a practical low-cost, large-area divergent physical pMBRT collimation system with validated MC modeling. In addition, we introduce complementary accessories that substantially expand system versatility to facilitate clinical implementation.
Predicting Remaining Survival of Glioblastoma Patients with Radiomics Analysis Based on 18F-DOPA PET Images
Qian, J. , Hasenauer, Deanna , Breen, William G. , Brown, Paul D. , Hunt, Christopher H. , Jacobson, Mark, Johnson, Derek R. , Kaufmann, Timothy J. , Kemp, Bradley J. , Kizilbash, Sani H. , Lowe, Val J. , Ruff, Michael W. , Sarkaria, Jann N. , Uhm, Joon H. , Zakhary, Mark J. , Seaberg, Maasa , Tseung, Hok Seum Wan Chan, Yan, Elizabeth , Zhang, Yan , Laack, Nadia N. , Brinkmann, Debra H. , Kemp, Brad , Qian, Jing , Jacobson, Mark S, Seaberg, Maasa H , Wan Chan Tseung, Hok Seum, Yan, Elizabeth S, Laack, Nadia N Issa , Kaufmann, Timothy J , Hunt, Christopher H , Sarkaria, Jann N , Johnson, Derek R , Kizilbash, Sani H , Lowe, Val J

Cancers | November 3, 2025 | Volume: 17 | Issue: 21 | Pages: 3560

10.3390/cancers17213560 Get It

Background: Post-treatment prognosis and monitoring are critical for determining the timing of salvage treatment in glioblastoma patients but has been challenging due to difficulties differentiating progression from treatment effects in conventional images. This exploratory study aimed to establish the correlation of radiomics image features from time series of amino acid tracer 18F-DOPA PET images, with outcomes, using machine learning and dimension reduction analysis. Methods: 18F-DOPA PET images were collected for a patient cohort with wild-type IDH and unmethylated MGMT who underwent dose-escalated radiation therapy. Quantitative features were derived from the high uptake region (T/N > 2.0) in pre- and post-radiation therapy follow-up 18F-DOPA PET images. A customized workflow was utilized for pre-selecting predictive features, followed by manifold learning. Machine learning algorithms were employed to establish associations between imaging features and remaining survival (RS), defined as the time between a follow-up scan and date of death. Results: The ML models exhibited 81–83% ROC_AUC in predicting RS evaluated on an independent test dataset. A RS map is proposed for monitoring tumor alterations through serial 18F-DOPA PET scans, demonstrating superior sensitivity and better correlation with survival compared to the RANO criteria. Conclusions: Our study demonstrates that ML models utilizing FU 18F-DOPA PET images have the potential to effectively predict future survival outcomes in patients with glioblastoma treated with dose-escalated radiation therapy. The capability to assess changes in tumor over time through imaging can potentially assist in patient stratification and the selection of salvage treatments, while also aiding in distinguishing treatment effects from genuine tumor progression.
Mini‐lattice radiation therapy: A treatment planning approach to miniaturize spatially fractionated lattice radiation therapy using a clinical linear accelerator
Hara, Daiki , Abou‐Mourad, Houssam, Thull, Jack C., Laack, Nadia N., Self, Chelsea, Fernandez‐Rodriguez, Alfredo , Prezado, Yolanda , Tseung, Hok Seum Wan Chan, Breen, William G. , Mutter, Robert W. , Antolak, John A. , Tseung, Hok Seum W C, Lester, Scott C. , Park, Sean S. , Grams, Michael P.

Medical Physics | September 29, 2025 | Volume: 52 | Issue: 10 | Pages: No page available

10.1002/mp.70027 Get It

Abstract Background Spatially fractionated radiation therapy (SFRT) is a technique that delivers heterogenous dose distributions consisting of alternating regions of high dose “peaks” and low dose “valleys”. Current delivery methods for SFRT using megavoltage x‐rays usually treat large and bulky tumors with brass grid or volumetric modulated arc therapy (VMAT) lattice techniques. The size and spacing of high dose regions in these approaches are typically on the order of centimeters. However, multiple studies have suggested that decreasing these dimensions may improve the therapeutic ratio. Furthermore, a more compact approach to SFRT would allow for a greater number of high dose regions within the tumor, as well as application to smaller and more irregularly shaped targets thereby increasing the number of patients that could benefit from SFRT. Purpose This study describes the commissioning and first patient treatment using mini‐lattice radiation therapy (MLRT). MLRT uses a clinical linear accelerator and decreases the size and spacing of standard lattice SFRT by using individual multileaf collimator (MLC) leaves to deliver 5 mm wide high dose regions. Methods MLRT plans were created in the Varian Eclipse treatment planning system for a Varian Truebeam equipped with Millennium 120 MLCs. MLRT uses 6 MV Flattening Filter Free high dose rate and the width of individual MLCs to define 5 mm by 5 mm openings separated by closed MLCs to deliver alternating opened and blocked regions. Dynamic conformal arcs were used to conform MLCs to 4 mm spherical mini‐lattice structures in the gross tumor volume (GTV). A MLRT‐specific beam model was commissioned to accurately model the small MLRT fields. Film measurements were performed to assess the accuracy of MLRT plans calculations. Plans for seven treatment sites in different parts of the body for retrospective patient candidates were created with varying numbers of mini‐lattices and separation distances to assess the impact of varying these parameters on treatment dose metrics. MLRT was used for the first time to treat a patient with two fractions of MLRT. Results The AcurosXB calculation algorithm with modified x and y spot sizes, dosimetric leaf gap, transmission factor, and output factor table was used to generate a beam model for accurate MLRT calculations. The MLRT‐specific beam model resulted in gamma passing rates (1%/0.5 mm criteria) of 90%–99% for retrospective patient MLRT film measurements. Dose volume histogram statistics, equivalent uniform dose, and mean dose showed a higher number of mini‐lattices with smaller separation increased the dose to the GTV and surrounding tissue. Separation distances between mini‐lattices did not impact plan heterogeneity as measured by D10%/D90%. The first patient treated with the MLRT technique reported pain relief, had stable disease, and no acute toxicities following both fractions. Conclusions MLRT is feasible using clinical linear accelerators and existing radiation oncology infrastructure. It enables targeting smaller tumors with SFRT, allows for a greater number of high dose regions within the target compared to standard VMAT lattice techniques, and may be a useful technique for challenging treatment scenarios.
RADT-15. 18F-DOPA PET/CT SURVEILLANCE FOR GLIOBLASTOMA: A RADIOMIC MODEL FROM A PROSPECTIVE PHASE II CLINICAL TRIAL PREDICTING SURVIVAL IN IDH-WILDTYPE, MGMT-UNMETHYLATED PATIENTS
Pafundi, Deanna, Breen, William G. , Brown, Paul D. , Jacobson, Mark, Kemp, Bradley J. , Lowe, Val J. , Ruff, Michael W. , Uhm, Joon H. , Tseung, Hok Seum Wan Chan, Yan, Elizabeth , Zhang, Yan , Laack, Nadia N., Brinkmann, Debra H. , Qian, Jing, Hunt, Christopher H. , Johnson, Derek R. , Kaufmann, Timothy J. , Kizilbash, Sani H. , Sarkaria, Jann N.

Neuro-Oncology | November 14, 2022 | Volume: 24 | Issue: Supplement_7 | Pages: vii52-vii52

10.1093/neuonc/noac209.205 Get It

Abstract BACKGROUND Interpretation of serial magnetic resonance imaging (MRI) for glioblastoma following radiation therapy (RT) is complicated by difficulty differentiating tumor from treatment-related changes, even using updated RANO criteria. The incorporation of novel imaging such as 3,4-dihydroxy-6-[18F]-fluoro-L-phenylalanine (18F-DOPA) PET/CT to post-treatment serial imaging may improve prognostication and better facilitate future treatment decisions. METHODS The secondary analysis of a recent phase II prospective clinical trial of 18F-DOPA PET/CT-directed dose-escalated RT included patients with IDH-wildtype, MGMT-unmethylated glioblastoma who underwent post-treatment serial 18F-DOPA PET/CT surveillance. Quantitative features were extracted from pre-RT and post-RT serial PET/CT images, and robust prognostic features were selected using an in-house workflow. Both an automated machine learning (ML) algorithm and an interpretable ML algorithm were utilized to correlate surveillance PET image features with subsequent survival of greater than 12 months versus less than 12 months from the surveillance timepoint. Changes from pre-RT to post-RT PET/CT (delta model) were also assessed for association with post-RT survival and validated with a separate cohort. RESULTS Thirty-five patients with IDH-wildtype, MGMT-unmethylated glioblastoma who had at least one available (range: 1-14) post-treatment 18F-DOPA PET/CT were included. Twenty-four were used for model training, while 11 were used for validation. Ultimately, a five-feature post-RT model utilizing two shape, two texture, and one first-order radiomic feature was selected. For the delta model, five texture, two shape, and one first order radiomic feature were selected. The models show 90% accuracy in predicting survival < 12 months post-surveillance on the training set, and 68%-73% accuracy (AUC 0.64-0.73) for the validation cohort. Delta features were significantly associated with overall survival (p < 0.05). CONCLUSIONS Post-RT serial 18F-DOPA PET/CT imaging can help distinguish true tumor progression in patients with glioblastoma using a radiomics model. Tumor response evaluated for changes from pre-RT to post-RT 18F-DOPA PET/CT also predicted subsequent overall survival.
Physical characterization of therapeutic proton delivery through common dental materials
Hu, Yue‐Houng , Tseung, Hok Seum Wan Chan, Mundy, Daniel W. , Wan Chan Tseung, Hok Seum

Medical Physics | March 12, 2022 | Volume: 49 | Issue: 5 | Pages: 2904-2913

10.1002/mp.15602 Get It

AbstractPurposeDental fixtures are commonplace in an aging, radiation treatment population. The current, local standard of practice in particle therapy is to employ treatment geometries to avoid delivery through implanted dental fixtures. The present study aims to observe the physical effect of delivering therapeutic proton beams through common dental fixture materials as prelude to an eventual goal of assessing the feasibility of using treatment geometries not specified for avoidance of oral implants. A sampling of common dental materials was selected based on prosthodontic consult and was evaluated in terms of relative stopping power and three‐dimensional (3D) dose perturbation.MethodsAmalgams, porcelain‐fused‐to‐metal (PFM) crowns consisting of zirconia and non‐noble base metals, and lithium disilicate implants were chosen for analysis. Theoretical stopping power (S) and mass stopping power (S/ρ) were calculated using the Stopping and Range of Ions in Matter (SRIM) application, basing stoichiometric compositions of each fixture on published materials data. S and S/ρ were calculated for a range of historically available compositions of amalgams from 1900 until the current era. The perturbance of S and S/ρ as a function of clinically relevant ranges of amalgam compositions for the modern era was analyzed. Water equivalent thickness (WET) and relative stopping power (Srel) of each material was measured for a clinical spot‐scanning proton beam with monoenergies of 159.9 and 228.8 MeV with a multi‐layer ionization chamber (MLIC). Subsequently, 3D dose perturbation was assessed by delivering proton beams through a custom phantom designed to simulate both en‐face and on‐edge treatment geometries through the selected materials. A treatment plan mimicking the experimental delivery was constructed in the institutional treatment planning system and calculated using TOPAS‐based Monte Carlo simulation (MCS). Experimental results were used to validate the MCS. Finally, treatment planning system (TPS) outputs were compared to MCS to determine the accuracy of the dose calculation model.ResultsHistorical compositions of amalgams ranged in S from 44.8 to 42.9 MeV/cm, with the greatest deviation being observed for the 1900–1959 era. Deviation as a function of amalgam composition from the modern era was most sensitive to proportion of Hg, accounting for deviations up to ‐4.2% at the greatest clinically relevant concentration. S/ρ was not found to vary greatly between each porcelain and metal alloy material for PFM type crowns. Relative stopping powers ranged between 1.3 and 5.4 for all studied materials, suggesting substantial changes in proton range with respect to water. Film measurements of pristine spots confirm dose perturbance and shortening of proton range, with an upstream shift of each Bragg peak being observed directly behind the installed fixture. At high energies, cold spots were found in all cases directly behind each material feature with a medial fill‐in of dose occurring distally. Qualitative agreement of spot perturbance was confirmed between film measurements and MCS. Finally, when comparing integrated depth doses (IDD) by summing over all axial directions, good agreement is observed between TPS and MCS.ConclusionsAll dental materials studied substantially perturbed the dosimetry of pristine proton spots both in terms of WET/Srel as well as the spatial distribution of dose. Proton range was quantifiably shortened, and each dental material affected a cold spot directly behind the object with medial dose back‐filling was observed distally. MCS and Eclipse dose calculations exhibited good agreement with measurements, suggesting that treatment planning without employing avoidance strategies may be possible with further investigation.
CTNI-28. VOLUMETRIC AND DOSIMETRIC PATTERNS OF FAILURE ANALYSIS OF A PHASE II CLINICAL TRIAL OF 18F-DOPA-PET DIRECTED DOSE ESCALATED RADIOTHERAPY FOR GLIOBLASTOMA
Breen, William G. , Anderson, S. Keith , Pafundi, Deanna, Lowe, Val J. , Vogen, Diane, Yan, Elizabeth , Brown, Paul D. , Uhm, Joon H. , Ruff, Michael W. , Zakhary, Mark J. , Zhang, Yan , Seaberg, Maasa , Rehim, Abdou Abdel , Tseung, Hok Seum Wan Chan, Kabat, Brian, Kemp, Bradley J. , Brinkmann, Debra H. , Kaufmann, Timothy J. , Hunt, Christopher H. , Sarkaria, Jann N. , Kizilbash, Sani H. , Qian, Jing, Laack, Nadia N.

Neuro-Oncology | November 18, 2021 | Volume: 23 | Issue: Supplement_6 | Pages: vi65-vi65

10.1093/neuonc/noab196.253 Get It

Abstract While dose escalation of radiotherapy (DERT) has failed to improve overall survival (OS) or progression-free survival (PFS) for glioblastoma in previous studies, a recent phase II clinical trial utilizing 18F-DOPA-PET-directed DERT demonstrated improved PFS in MGMT-unmethylated patients and OS in MGMT-methylated patients compared to historical controls. This planned secondary analysis sought to determine 1) how 18F-DOPA-PET changes RT volumes beyond standard MRI-planning, 2) which patients benefit most and least from this protocol, 3) which are mostly likely to experience clinically significant radionecrosis after DERT, and 4) patterns of failure after DERT. For 69 evaluable patients, median MRI-defined, PET-defined, and combined low-dose gross tumor volumes (GTV51) were 54 cc (range 9-248), 23 cc (0.4-179), and 62 cc (10-260), respectively. Median MRI-defined, PET-defined, and combined high-dose GTVs (GTV76) were 32 cc (range 4-136), 6 cc (0.1-138), and 34 cc (4-162), respectively. 18F-DOPA-PET resulted in a median volumetric expansion of 13% (0-243%) and 5% (0-217%) from MRI-defined low-dose and high-dose GTV’s, respectively. Central failures ( >95% of recurrence tumor volume) occurred within the 76 Gy, 60 Gy, and 51 Gy isodose lines in 32 (46%), 60 (87%), and 64 (93%) patients, respectively. Recursive partitioning analysis stratified patients by OS and PFS. Patients with 18F-DOPA-PET-defined GTV76 > 7.8cc, MRI-defined GTV76 > 42.7cc, and MGMT promotor-unmethylated tumors had the shortest OS, while patients with smaller PET and MRI-defined tumors had the longest OS (median 10.4 vs. 64.6 months, p< 0.001). Similarly, PFS was worst in patients with 18F-DOPA-PET-defined GTV76 > 2.17 cc who had biopsy only (median PFS 3.2 months, p< 0.001). Patients with 18F-DOPA-PET-defined GTV51 > 50 cc had the highest risk of grade 3+ radionecrosis (p< 0.001). In conclusion, larger 18F-DOPA-PET and MRI-defined tumor volumes were associated with worse outcomes, and 18F-DOPA-PET-directed DERT appears to reduce risk of central recurrence in high-dose volumes.
RTHP-16. RADIATION INDUCED SIGNAL CHANGES ON MAGNETIC RESONANCE IMAGING IN ADULT PATIENTS WITH BRAIN TUMORS TREATED WITH PENCIL BEAM SCANNING PROTON THERAPY
Rongthong, Warissara , Tseung, Hok Seum Wan Chan, Roberts, Kristofer, Vora, Sujay A., Mahajan, Anita , Laack, Nadia N. , Beltran, Chris , Roberts, Kristofer

Neuro-Oncology | November 5, 2018 | Volume: 20 | Issue: suppl_6 | Pages: vi228-vi228

10.1093/neuonc/noy148.947 Get It

RTHP-02. IMPACT OF 18F-DOPA PET ON RADIOTHERAPY TARGET VOLUMES FOR NEWLY DIAGNOSED MGMT UNMETHYLATED GLIOBLASTOMA PATIENTS; PRELIMINARY RESULTS OF A PHASE II DOSE-ESCALATION TRIAL
Brinkmann, Debra H. , Pafundi, Deanna, Lowe, Val J. , Yan, Elizabeth , Brown, Paul D. , Zakhary, Mark J. , Seaberg, Maasa , Tseung, Hok Seum Wan Chan, Hunt, Christopher H. , Zhang, Yan, Sarkaria, Jann N. , Laack, Nadia N.

Neuro-Oncology | November 5, 2018 | Volume: 20 | Issue: suppl_6 | Pages: vi225-vi225

10.1093/neuonc/noy148.934 Get It

ACTR-12. PRELIMINARY SAFETY AND EFFICACY OF A PHASE II TRIAL OF 18F-DOPA PET-GUIDED, DOSE-ESCALATED RADIOTHERAPY IN THE TREATMENT OF GLIOBLASTOMA
Pafundi, Deanna, Anderson, S. Keith , Zakhary, Mark J. , Tseung, Hok Seum Wan Chan, Lowe, Val J. , Yan, Elizabeth , Kizilbash, Sani H. , Uhm, Joon H. , Hu, Leland , Brown, Paul D. , Buckner, Jan C. , Brinkmann, Debra H. , Kizilbash, Sani H , Laack, Nadia N. , Hunt, Christopher H. , Kaufmann, Timothy J. , Sarkaria, Jann N.

Neuro-Oncology | November 5, 2018 | Volume: 20 | Issue: suppl_6 | Pages: vi13-vi13

10.1093/neuonc/noy148.046 Get It

A Monte‐Carlo‐based and GPU‐accelerated 4D‐dose calculator for a pencil beam scanning proton therapy system
Pepin, M. , Tryggestad, E., Tseung, Hok Seum Wan Chan, Johnson, J. , Herman, Michael , Beltran, Chris , Pepin, Mark D, Tryggestad, Erik, Wan Chan Tseung, Hok Seum, Johnson, Jedediah E, Herman, Michael G., Beltran, Chris J , Pepin, Mark D

Medical Physics | September 11, 2018 | Volume: 45 | Issue: 11 | Pages: 5293-5304

10.1002/mp.13182 Get It

PurposeThe presence of respiratory motion during radiation treatment leads to degradation of the expected dose distribution, both for target coverage and healthy tissue sparing, particularly for techniques like pencil beam scanning proton therapy which have dynamic delivery systems. While tools exist to estimate this degraded four‐dimensional (4D) dose, they typically have one or more deficiencies such as not including the particular effects from a dynamic delivery, using analytical dose calculations, and/or using nonphysical dose‐accumulation methods. This work presents a clinically useful 4D‐dose calculator that addresses each of these shortcomings.MethodsTo quickly compute the 4D dose, the three main tasks of the calculator were run on graphics processing units (GPUs). These tasks were (a) simulating the delivery of the plan using measured delivery parameters to distribute the plan amongst 4DCT phases characterizing the patient breathing, (b) using an in‐house Monte Carlo simulation (MC) dose calculator to determine the dose delivered to each breathing phase, and (c) accumulating the doses from the various breathing phases onto a single phase for evaluation. The accumulation was performed by individually transferring the energy and mass of dose‐grid subvoxels, a technique that models the transfer of dose in a more physically realistic manner. The calculator was run on three test cases, with lung, esophagus, and liver targets, respectively, to assess the various uncertainties in the beam delivery simulation as well as to characterize the dose‐accumulation technique.ResultsFour‐dimensional doses were successfully computed for the three test cases with computation times ranging from 4–6 min on a server with eight NVIDIA Titan X graphics cards; the most time‐consuming component was the MC dose engine. The subvoxel‐based dose‐accumulation technique produced stable 4D‐dose distributions at subvoxel scales of 0.5–1.0 mm without impairing the total computation time. The uncertainties in the beam delivery simulation led to moderate variations of the dose–volume histograms for these cases; the variations were reduced by implementing repainting or phase‐gating motion mitigation techniques in the calculator.ConclusionsA MC‐based and GPU‐accelerated 4D‐dose calculator was developed to estimate the effects of respiratory motion on pencil beam scanning proton therapy treatments. After future validation, the calculator could be used to assess treatment plans and its quick runtime would make it easily usable in a future 4D‐robust optimization system.