Back to Authors

Diehn, Felix E.

https://orcid.org/0000-0001-9458-8017

Mayo Clinic

Mayo Clinic

Citations 47

Immune checkpoint inhibitor-associated myopathy: a clinicoseropathologically distinct myopathy
Shelly, Shahar , Triplett, James , Pinto, Marcus Vinícius , Milone, Margherita , Ζεκερίδου, Αναστασία , Liewluck, Teerin , Triplett, James D, Pinto, Marcus V , Diehn, Felix E. , Liewluck, T , Shahar, Shelly , Triplett, James D

Brain Communications | November 2, 2020 | Volume: 2 | Issue: 2 | Pages: No page available

10.1093/braincomms/fcaa181 Get It

Abstract Immune checkpoint inhibitors have revolutionized the landscape of cancer treatment. Alongside their many advantages, they elicit immune-related adverse events, including myopathy, which potentially result in substantial morbidity if not recognized and treated promptly. Current knowledge of immune checkpoint inhibitor-associated myopathy is limited. We conducted a 5-year retrospective study of patients with immune checkpoint inhibitor-associated myopathy. Clinical features, survival and ancillary test findings were analysed and compared with those of immune-mediated necrotizing myopathy patients without immune checkpoint inhibitor exposure seen during the same time period. We identified 24 patients with immune checkpoint inhibitor-associated myopathy (median age 69 years; range 28–86) and 38 patients with immune-mediated necrotizing myopathy. Ocular involvement occurred in 9/24 patients with immune checkpoint inhibitor exposure, without electrodiagnostic evidence of neuromuscular transmission defect, and in none of the immune-mediated necrotizing myopathy patients (P < 0.001). Myocarditis occurred in eight immune checkpoint inhibitor-associated myopathy patients and in none of the immune-mediated necrotizing myopathy patients (P < 0.001). Median creatine kinase was 686 IU/l in the immune checkpoint inhibitor cohort (seven with normal creatine kinase) compared to 6456 IU/l in immune-mediated necrotizing myopathy cohort (P < 0.001). Lymphopenia was observed in 18 and 7 patients with and without immune checkpoint inhibitor exposure, respectively (P < 0.001). Myopathological findings were similar between patients with and without immune checkpoint inhibitor exposure, consisting of necrotic fibres with no or subtle inflammation. Necrotic fibres however arranged in clusters in 10/11 immune checkpoint inhibitor-associated myopathy patients but in none of the immune checkpoint inhibitor-naïve patients (P < 0.001). Despite the lower creatine kinase levels in immune checkpoint inhibitor-exposed patients, the number of necrotic fibres was similar in both groups. Immune checkpoint inhibitor-associated myopathy patients had a higher frequency of mitochondrial abnormalities and less number of regenerating fibres than immune-mediated necrotizing myopathy patients (P < 0.001). Anti-hydroxy-3-methylglutaryl-CoA reductase or signal recognition particle antibodies were absent in patients with immune checkpoint inhibitor exposure but positive in two-thirds of immune checkpoint inhibitor-naïve patients. Most patients with immune checkpoint inhibitor-associated myopathy responded favourably to immunomodulatory treatments, but four died from myopathy-related complications and one from myocarditis. Intubated patients had significantly shorter survival compared to non-intubated patients (median survival of 22 days; P = 0.004). In summary, immune checkpoint inhibitor-associated myopathy is a distinct, treatable immune-mediated myopathy with common ocular involvement, frequent lymphopenia and necrotizing histopathology, which contrary to immune-mediated necrotizing myopathy, is featured by clusters of necrotic fibres and not accompanied by anti-hydroxy-3-methylglutaryl-CoA reductase or signal recognition particle antibodies. Normal or mildly elevated creatine kinase level does not exclude the diagnosis.
Spinal Cord Cavernous Malformations: MRI Commonly Shows Adjacent Intramedullary Hemorrhage
Panda, Ananya , Diehn, Felix E. , Kim, Dong Kun , Bydon, Mohamad , Rinaldo, Lorenzo , Flemming, Kelly D. , Benson, John C. , Carr, Carrie M. , Flemming, Kelly D , Diehn, Felix E , Goyal, Anshit , Lanzino, Giuseppe

Journal of Neuroimaging | May 28, 2020 | Volume: 30 | Issue: 5 | Pages: 690-696

10.1111/jon.12738 Get It

ABSTRACTBACKGROUND AND PURPOSEThere is a relative paucity of radiology literature on spinal cord cavernous malformations (SCMs). We hypothesized that the classic MRI features of cavernous malformations are not highly prevalent. The purpose was to review MR imaging findings of SCMs with a focus on prevalence of hemorrhagic features, including adjacent intramedullary hemorrhage at initial presentation.METHODSIn this single‐institution study, 78 SCMs in 76 patients diagnosed on imaging/pathology were retrospectively evaluated for size, location, cord expansion, exophytic component, popcorn morphology, signal characteristics, including T1 weighted (T1w) and T2w rims, blood‐fluid levels, and adjacent intramedullary hemorrhage. Intramedullary hemorrhage was defined as centrally and/or eccentrically located linear or flame shaped non‐edematous signal abnormality extending longitudinally away from SCMs, distinct from lesional rim.RESULTSSixty‐three percent (49/78) of SCMs measured <1 cm in length, 78% (61/78) extended to the cord surface, 65% (51/78) were expansile, and 32% (25/78) were exophytic. Popcorn morphology was seen in 15% (12/78) on T1w and 22% (17/78) on T2w. Internal blood‐fluid levels were evident in 4% (3/78). Sixty‐nine percent (54/78) showed T2w hypointense rims; the T2w rim was complete/near‐complete in 37% (29/78). A rim on T1w was visible in 49% (38/78); this was hyperintense in 58% (22/38). Adjacent intramedullary hemorrhage was seen in 45/78 (58%), was most commonly bidirectional in 67% (30/45) and eccentric in 68% (30/44). Cord edema was seen in 22% (17/78); 53% (9/17) also demonstrated intramedullary hemorrhage with edema.CONCLUSIONSThe classically described popcorn morphology, internal blood‐fluid levels, and complete/near‐complete T2w hypointense rims are often absent on MRIs in SCMs. Adjacent intramedullary hemorrhage is frequently present, often eccentric and bidirectional.
Synovial Cysts Confounding Access to the Dorsal S1 Neural Foramen in Transforaminal Epidural Steroid Injections
El-Yahchouchi, Christine, Willard, Frank, Wald, John T. , Geske, Jennifer R. , Maus, Timothy P. , Kaufmann, Timothy J. , Diehn, Felix E. , Geske, Jennifer

Pain Medicine | October 10, 2019 | Volume: 21 | Issue: 3 | Pages: 570-575

10.1093/pm/pnz298 Get It

Abstract Objectives The S1 dorsal foramen is the route for 30% of lumbar transforaminal epidural injections; it is therefore important to identify structures impeding S1 foraminal access. The study objective was to characterize the imaging findings, prevalence, and anatomic origin of synovial cysts presenting within the S1 neural foramen. Methods A case series (N = 14) established imaging characteristics of S1 synovial cysts. Imaging studies of 400 patients undergoing epidural injections were reviewed for lesions compromising S1 foraminal access. Cadaveric dissections defined the relationship of the inferior recess of the L5-S1 facet to the S1 dorsal foramen. Results Elderly patients (mean age = 76) exhibited S1 synovial cysts. Synovial cysts were typically 1–2 cm in diameter, hyperintense on sagittal T2 weighted magnetic resonance images (MRIs), fluid-density on computed tomography, and dorsal to the S1 spinal nerve. Sixty percent of cysts exhibited complex MRI signal characteristics (thick wall, internal structure). Tarlov cysts, in contrast, were larger, lobular, and exhibited pure fluid intensity. Lesions impeded access to the S1 dorsal foramina in 5% of reviewed imaging studies (16 Tarlov cysts, three synovial cysts, one conjoint S1-S2 nerve root). The multifidus muscle was interposed between the L5-S1 facet inferior recess and the S1 dorsal foramen on dissection specimens; severe atrophy of the ipsilateral multifidus was noted on imaging in 17/18 synovial cysts. Conclusions The S1 neural foramina should be inspected on sagittal MRI, when available, for confounding lesions before performing S1 epidural injections. Tarlov cysts are more common than synovial cysts; the latter are seen in elderly patients with severe multifidus atrophy.
Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration
Zhou, Wei , Bartlett, David J. , Glazebrook, Katrina N. , Carter, Rickey E. , Zhou, Wei , Carter, Rickey E , Diehn, Felix E. , Kotsenas, Amy L. , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Investigative Radiology | December 18, 2018 | Volume: 54 | Issue: 4 | Pages: 204-211

10.1097/rli.0000000000000535 Get It

Objectives The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. Materials and Methods A 3D-printed spine with pedicle screws was scanned on a PCD-CT system with and without tin filtration. Image noise and severity of artifacts were measured for low-energy threshold (TL) and TH images. In a prospective, institutional review board–approved, Health Insurance Portability and Accountability Act-compliant study, 20 patients having a clinical energy-integrating detector (EID) CT were scanned on a PCD-CT system using tin filtration. Images were reviewed by 3 radiologists to evaluate visualization of anatomic structures, diagnostic confidence, and image preference. Artifact severity and image noise were measured. Wilcoxon signed rank was used to test differences between PCD-CT TH and EID-CT images. Results Phantom TH images with tin filtration reduced metal artifacts and had comparable noise (32 HU) to TL images (29 HU) acquired without tin filtration. Visualization scores for the cortex, trabeculae, and implant-trabecular interface from PCD-CT TH images (4.4 ± 0.9, 4.4 ± 1.0, and 4.4 ± 1.0) were significantly higher (P < 0.0001) than EID-CT images (3.3 ± 1.3, 3.3 ± 1.2, and 3.3 ± 1.6). A strong preference was shown for PCD-CT TH images due to improved diagnostic confidence and decreased artifact severity. Noise in PCD-CT TH images (93 ± 41 HU) was significantly lower than that in EID-CT images (133 ± 92 HU, P < 0.05). Conclusions Threshold high images acquired with tin filtration on PCD-CT demonstrated a substantial decrease in metal artifacts and an increase in dose efficiency compared with EID-CT.
Unilateral Epidural Targeting of Resiniferatoxin Induces Bilateral Neurolysis of Spinal Nociceptive Afferents
Unger, Mark, Pleticha, Josef, Steinauer, Joanne , Kanwar, Rahul , LaVallee, Katherine T, Banck, Michaela S., Jones, Bryan, Yaksh, Tony L. , Maus, Timothy P. , Beutler, Andreas S. , Unger, Mark D, Diehn, Felix, Diehn, Felix E.

Pain Medicine | November 6, 2018 | Volume: 20 | Issue: 5 | Pages: 897-906

10.1093/pm/pny276 Get It

A novel etiology for craniospinal hypovolemia: a case of inferior vena cava obstruction
Kumar, Neeraj , Neidert, Newton B. , Bjarnason, Haraldur , Diehn, Felix E. , Bjarnason, Haraldur , Campeau, Norbert G. , Morris, Jonathan M.

Journal of Neurosurgery: Spine | July 13, 2018 | Volume: 29 | Issue: 4 | Pages: 452-455

10.3171/2018.2.spine171373 Get It

The authors report on a patient with craniospinal hypovolemia and inferior vena cava obstruction, and describe how the two conditions may be linked. This unique report further advances the emerging literature on spinal CSF venous fistulae.
CT Dental Artifact: Comparison of an Iterative Metal Artifact Reduction Technique with Weighted Filtered Back-Projection
Diehn, Felix E. , Michalak, Gregory J. , Kotsenas, Amy L. , Lindell, E. Paul , Halaweish, Ahmed F., DeLone, David R. , Campeau, Norbert G , Halaweish, Ahmed F , Campeau, Norbert G. , McCollough, Cynthia H. , Fletcher, Joel G. , Diehn, Felix E

Acta Radiologica Open | November 27, 2017 | Volume: 6 | Issue: 11 | Pages: 205846011774327

10.1177/2058460117743279 Get It

Background Dental hardware produces streak artifacts on computed tomography (CT) images reconstructed with the standard weighted filtered back projection (wFBP) method. Purpose To perform a preliminary evaluation of an iterative metal artifact reduction (IMAR) technique to assess its ability to improve anatomic visualization over wFBP in patients with dental amalgam or other hardware. Material and Methods CT images from patients with dental hardware were reconstructed using wFBP and IMAR software and soft-tissue or bone window/level settings. The anatomy most affected by metal artifacts was identified. Two neuroradiologists determined subjective and objective imaging features, including overall metal artifact score (1 = severe artifacts, 5 = no artifacts), soft-tissue visualization score of the most-compromised structure, and artifact length along the skin surface. CT numbers were used to quantify artifact severity. Results Twenty-four patients were included. IMAR improved overall metal artifact score in 18/24 cases (median =2 ± 0.9 vs. 1 ± 0.6, P < 0.001). Mean CT number in the most-affected anatomical structure significantly improved with IMAR (94.6 vs. 219 HU, P = 0.002) and length of affected skin surface decreased (40.4 mm vs. 118.7 mm, P < 0.001). However, osseous/dental artifactual defects were found in 22/24 cases with IMAR vs. 11/24 with wFBP. Conclusion IMAR software reduced metal artifact both subjectively and objectively and improved visualization of adjacent soft tissues. However, it produced a higher rate of artifactual defects in the teeth and bones than wFBP. Our findings support the use of IMAR as a valuable complement to, but not a replacement for, standard wFBP image reconstruction.
Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography
Carlson, Matthew L. , Witte, Robert J. , Krecke, Karl N. , Grimes, Josh, Koeller, Kelly K. , Bruesewitz, Michael R. , Lane, John I. , Leng, Shuai , Diehn, Felix E. , McCollough, Cynthia H.

Otology & Neurotology | May 31, 2017 | Volume: 38 | Issue: 7 | Pages: 978-984

10.1097/mao.0000000000001463 Get It

Hypothesis: A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Background: Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Methods: Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Results: Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p < 0.01), superior scalar localization (p < 0.01), and reduced blooming artifact (p < 0.05), compared with conventional 64-slice MDCT. There was no significant difference between platforms when comparing streak or ring artifact. Conclusion: The new generation 192-slice MDCT scanner offers several notable advantages for cochlear implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.
Spinal CSF venous fistula: A treatable etiology for CSF leaks in craniospinal hypovolemia
Kumar, Neeraj , Verdoorn, Jared T. , Garza, Ivan , Atkinson, John L. D., Diehn, Felix E. , Carr, Carrie M. , Luetmer, Patrick H. , Morris, Jonathan M.

Neurology | May 14, 2016 | Volume: 86 | Issue: 24 | Pages: 2310-2312

10.1212/wnl.0000000000002776 Get It

Myelographic Techniques for the Detection of Spinal CSF Leaks in Spontaneous Intracranial Hypotension
Kranz, Peter G. , Tanpitukpongse, Teerath Peter , Gray, Linda , Luetmer, Patrick H. , Diehn, Felix E. , Amrhein, Timothy J. , Gray, Linda L. , Kranz, Peter G

American Journal of Roentgenology | December 23, 2015 | Volume: 206 | Issue: 1 | Pages: 8-19

10.2214/ajr.15.14884 Get It