Back to Authors

An, K-N.

Mayo Clinic

Mayo Clinic

Citations 9

Biological analysis of flexor tendon repair-failure stump tissue: a potential recycling of tissue for tendon regeneration
Lu, Cheng‐Chang , Zhang, T., Reisdorf, Ramona L., Amadio, Peter C. , An, K-N, Moran, Steven L. , Gingery, Anne , Zhao, Chunfeng , An, K-N., Gingery, Anne

Bone & Joint Research | June 14, 2019 | Volume: 8 | Issue: 6 | Pages: 232-245

10.1302/2046-3758.86.bjr-2018-0239.r1 Get It

Objectives Re-rupture is common after primary flexor tendon repair. Characterization of the biological changes in the ruptured tendon stumps would be helpful, not only to understand the biological responses to the failed tendon repair, but also to investigate if the tendon stumps could be used as a recycling biomaterial for tendon regeneration in the secondary grafting surgery. Methods A canine flexor tendon repair and failure model was used. Following six weeks of repair failure, the tendon stumps were analyzed and characterized as isolated tendon-derived stem cells (TDSCs). Results Failed-repair stump tissue showed cellular accumulation of crumpled and disoriented collagen fibres. Compared with normal tendon, stump tissue had significantly higher gene expression of collagens I and III, matrix metalloproteinases (MMPs), vascular endothelial growth factor (VEGF), platelet-derived growth factor (PDGF), and insulin-like growth factor (IGF). The stump TDSCs presented both mesenchymal stem and haematopoietic cell markers with significantly increased expression of CD34, CD44, and CD90 markers. Stump TDSCs exhibited similar migration but a lower proliferation rate, as well as similar osteogenic differentiation but a lower chondrogenic/adipogenic differentiation capability, compared with normal TDSCs. Stump TDSCs also showed increasing levels of SRY-box 2 (Sox2), octamer-binding transcription factor 4 (Oct4), tenomodulin (TNMD), and scleraxis (Scx) protein and gene expression. Conclusion We found that a failed repair stump had increased cellularity that preserved both mesenchymal and haematopoietic stem cell characteristics, with higher collagen synthesis, MMP, and growth factor gene expression. This study provides evidence that tendon stump tissue has regenerative potential. Cite this article: C-C. Lu, T. Zhang, R. L. Reisdorf, P. C. Amadio, K-N. An, S. L. Moran, A. Gingery, C. Zhao. Biological analysis of flexor tendon repair-failure stump tissue: A potential recycling of tissue for tendon regeneration. Bone Joint Res 2019;8:232–245. DOI: 10.1302/2046-3758.86.BJR-2018-0239.R1.
Effect of the location of the split of the subscapularis on range of motion and stability of the glenohumeral joint following Latarjet or Trillat procedures
Nourissat, Geoffroy , Hooke, Alex, Berglund, Lars , Thoreson, Andrew R. , An, K-N, Werthel, J-D., Hooke, Alexander W. , An, K-N.

Orthopaedic Journal of Sports Medicine | May 30, 2019 | Volume: 7 | Issue: 5_suppl3 | Pages: No page available

10.1177/2325967119s00202 Get It

Aim: Compare the effect of Latarjet and Trillat procedures on glenohumeral stability and range of motion. Background: Little is known about the impact of the location of the sling effect on joint stability and range of motion. Methods: 12 cadaveric shoulders were cleaned of soft tissue except for the subscapularis, conjoined tendon, and anterior capsule. A custom-made apparatus generating anterior humeral translation and joint compression was used. The machine applied compression load in the medial direction. The subscapularis and conjoint tendon were loaded. Internal/external range of motion and joint stability were assessed at 0°, 30° and 60° glenohumeral abduction. Range of motion was assessed by rotating the humeral shaft. Joint stability was assessed at maximum external rotation, translating the humerus. Specimen were tested in five conditions: 1) intact shoulder, 2) 6-mm bony glenoid defect (20% defect) 3) Trillat procedure, 4) Latarjet procedure with subscapularis split at the junction between its superior 2/3rds and inferior 1/3 rd, 5) Latarjet procedure with subscapularis split at the superior 1/3rds and inferior 2/3rds. Means were compared with a full factorial-repeated measures ANOVA with pairwise post hoc comparisons. Results: Peak translation force and stability ratio were significantly lower with the glenoid defect when compared to the intact and all the repaired conditions at all levels of glenohumeral abduction. The level of the subscapularis split had no significant influence on these values and no significant difference could be found between Trillat and Latarjet procedures. Range of motion in internal and external rotation were not significantly different between the different conditions. Conclusions: Joint stability and range of motion after a Latarjet are not impacted by the location of the subscapularis muscle split. Trillat and Latarjet techniques provide comparable stabilization of the joint, even in the presence of a critical bony defect of the glenoid.
Kinematics of semi-constrained total elbow arthroplasty
An, K-N., Korinek, Sarah, Morrey, BF, O’Driscoll, Shawn W. , Morrey, BF

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 74-B | Issue: 2 | Pages: 297-299

10.1302/0301-620x.74b2.1544973 Get It

We used 11 cadaver elbows and a three-dimensional electromagnetic tracking device to record elbow movements before and after implantation of a 'loose-hinged' elbow prosthesis (modified Coonrad). During simulated active motion there was a maximum of 2.7 degrees (+/- 1.5 degrees) varus/valgus laxity in the cadaver joints. This increased slightly after total elbow arthroplasty to 3.8 degrees (+/- 1.4 degrees). These values are lower than those recorded for the cadaver joints and for the prostheses at the limits of their varus/valgus displacements, indicating that both behave as 'semi-constrained' joints under physiological conditions. They suggest that the muscles absorb some of the forces and moments that in a constrained prosthesis would be transferred to the prosthesis-bone interface.
Stabilising function of the biceps in stable and unstable shoulders
Itoi, Eiji, Kuechle, DK, Newman, Morrey, BF, An, K-N, An, K-N.

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 75-B | Issue: 4 | Pages: 546-550

10.1302/0301-620x.75b4.8331107 Get It

We studied the contributions of the long and short heads of the biceps (LHB, SHB) to anterior stability in 13 cadaver shoulders. The LHB and SHB were replaced by spring devices and translation tests at 90 degrees abduction of the arm were performed by applying a 1.5 kg anterior force. The position of the humeral head was monitored by an electromagnetic tracking device with or without an anterior translational force; with 0 kg, 1.5 kg or 3 kg loads applied on either LHB or SHB tendons in 60 degrees, 90 degrees or 120 degrees of external rotation; and with the capsule intact, vented, or damaged by a Bankart lesion. The anterior displacement of the humeral head under 1.5 kg force was significantly decreased by both the LHB and SHB loading in all capsular conditions when the arm was in 60 degrees or 90 degrees of external rotation. At 120 degrees of external rotation, anterior displacement was significantly decreased by LHB and SHB loading only when there was a Bankart lesion. We conclude that LHB and SHB have similar functions as anterior stabilizers of the glenohumeral joint with the arm in abduction and external rotation, and that their role increases as shoulder stability decreases. Both heads of the biceps have been shown to have a stabilising function in resisting anterior head displacement, and consideration should therefore be given to strengthening the biceps during rehabilitation programmes for chronic anterior instability of the shoulder.
Glenohumeral elevation studied in three dimensions
Browne, AO, Tanaka, Shinji , An, K-N., Morrey, BF, Hoffmeyer, Pierre

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 72-B | Issue: 5 | Pages: 843-845

10.1302/0301-620x.72b5.2211768 Get It

We studied the position and rotational changes associated with elevation of the glenohumeral joint, using a three-dimensional magnetic-field tracking system on nine fresh cadaveric shoulders. The plane of maximal arm elevation was shown to occur 23 degrees anterior to the plane of the scapula. Elevation in any plane anterior to the scapula required external humeral rotation, and maximal elevation was associated with approximately 35 degrees of external humeral rotation. Conversely, internal rotation was necessary for increased elevation posterior to the plane of the scapula. The observed effects of this rotation were to clear the humeral tuberosity from abutting beneath the acromion and to relax the inferior capsular ligamentous constraints. Measurement of the obligatory humeral rotation required for maximal elevation helps to explain the relationship of the limited elevation seen in adhesive capsulitis and after operations which limit external rotation.
Biomechanical analysis of the effect of congruence, depth and radius on the stability ratio of a simplistic ‘ball-and-socket’ joint model
Werthel, J-D., Thoreson, Andrew R. , Resch, Herbert, An, K-N, Moroder, Philipp , Ernstbrunner, Lukas , Werthel, J.D., Hatta, Taku , An, K-N.

Bone & Joint Research | October 12, 2016 | Volume: 5 | Issue: 10 | Pages: 453-460

10.1302/2046-3758.510.bjr-2016-0078.r1 Get It

ObjectivesThe bony shoulder stability ratio (BSSR) allows for quantification of the bony stabilisers in vivo. We aimed to biomechanically validate the BSSR, determine whether joint incongruence affects the stability ratio (SR) of a shoulder model, and determine the correct parameters (glenoid concavity versus humeral head radius) for calculation of the BSSR in vivo.MethodsFour polyethylene balls (radii: 19.1 mm to 38.1 mm) were used to mould four fitting sockets in four different depths (3.2 mm to 19.1mm). The SR was measured in biomechanical congruent and incongruent experimental series. The experimental SR of a congruent system was compared with the calculated SR based on the BSSR approach. Differences in SR between congruent and incongruent experimental conditions were quantified. Finally, the experimental SR was compared with either calculated SR based on the socket concavity or plastic ball radius.ResultsThe experimental SR is comparable with the calculated SR (mean difference 10%, sd 8%; relative values). The experimental incongruence study observed almost no differences (2%, sd 2%). The calculated SR on the basis of the socket concavity radius is superior in predicting the experimental SR (mean difference 10%, sd 9%) compared with the calculated SR based on the plastic ball radius (mean difference 42%, sd 55%).ConclusionThe present biomechanical investigation confirmed the validity of the BSSR. Incongruence has no significant effect on the SR of a shoulder model. In the event of an incongruent system, the calculation of the BSSR on the basis of the glenoid concavity radius is recommended. Cite this article: L. Ernstbrunner, J-D. Werthel, T. Hatta, A. R. Thoreson, H. Resch, K-N. An, P. Moroder. Biomechanical analysis of the effect of congruence, depth and radius on the stability ratio of a simplistic ‘ball-and-socket’ joint model. Bone Joint Res 2016;5:453–460. DOI: 10.1302/2046-3758.510.BJR-2016-0078.R1.
Prosthesis Design and Stress Profile after Hip Resurfacing: A Finite Element Analysis
Heijink, Andras, Zobitz, M. E., Nuyts, Rudy M. M. A., Morrey, BF, An, K-N, Morrey, BF, An, K-N.

Journal of Orthopaedic Surgery | October 4, 2016 | Volume: 16 | Issue: 3 | Pages: 326-332

10.1177/230949900801600312 Get It

Purpose. To evaluate the effect of prosthesis design on stress profile in the proximal femur after hip resurfacing. Methods. The von Mises stress profile of the native femur was simulated and compared with that of resurfaced femurs using various prosthetic materials (titanium, cobalt-chrome, ceramic), stem lengths (normal, half, short, and no stem), and femoral head coverage (shell size) [260°, 220°, 180°, and 140°]. Results. Hip resurfacing altered the stress profile of the cancellous (but not cortical) bone of the femoral neck. Maximal cortical stresses were observed at the posterior half of the medial femoral neck. The stress profile of the native femur was most similar to that of the resurfaced femur made of titanium, with a short or no stem and 260 degrees of femoral head coverage (shell size). Conclusion. Optimising prosthesis design by minimising biomechanical alterations seems a valid approach to achieving favourable long-term outcomes. Cadaveric and in vivo studies are needed to confirm the clinical relevance and feasibility.
Zona conoidea of the elbow
Jeon, I-H., Chun, J-M., Lee, C. S., Yoon, J-O., Kim, P.-T., An, K-N., Morrey, B.F., Shin, H-D., Jeon, I-H.

The Journal of Bone and Joint Surgery. British volume | March 20, 2012 | Volume: 94-B | Issue: 4 | Pages: 517-522

10.1302/0301-620x.94b4.27842 Get It

The zona conoidea comprises the area of the lateral trochlear ridge of the humerus. The purpose of this study is to reintroduce this term ‘zona conoidea’ to the discussion of the human elbow and to investigate its significance in the development of osteoarthritis of the elbow. The upper extremities of 12 cadavers were prepared. With the forearm in neutral, pronation and supination, the distance between the bevel of the radial head and zona conoidea was inspected. A total of 12 healthy volunteers had a CT scan. The distance between the zona conoidea and the bevelled rim of the radial head was measured in these positions. In the anatomical specimens, early osteo-arthritic changes were identified in the posteromedial bevelled rim of the radial head, and the corresponding zona conoidea in supination. Measurement in the CT study showed that in full supination, the distance between the bevel of the radial head and the zona conoidea was at a minimum. This study suggests that the significant contact between the bevel of the radial head and the zona conoidea in supination is associated with the initiation of osteoarthritis of the elbow in this area.
Effects of age and gender on the movement workspace of the trapeziometacarpal joint
Kuo, L-C, Cooney, W.P., An, K-N., Lai, K.Y., Wang, S-M, Su, Fong‐Chin , Kuo, Li‐Chieh , Kuo, L-C, Wang, S-M

Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | December 12, 2008 | Volume: 223 | Issue: 2 | Pages: 133-142

10.1243/09544119jeim489 Get It

While researchers have suggested that joint mobility would probably be affected by age and gender, research findings often present discrepancies. Little research has been performed on the factors which effect mobility of the trapeziometacarpal (TMC) joint. The purpose of this study was to address the effects of age and gender on the ranges of motion of the normal TMC joint. Eighty normal subjects divided into four age groups participated in this study. The TMC joint motions were recorded using an electromagnetic tracking system. In order to achieve a maximal range of TMC joint motion which was defined as the maximal workspace, each subject was asked to perform actively maximal circumduction, flexion—extension, and abduction—adduction of the TMC joint. Numerical and statistical methods were used to compute the TMC workspace and to detect significant differences. A workspace-to-length ratio was determined as an index to examine the effects of the age and gender on the joint mobility. The results demonstrated that age and gender had significant influences on the TMC workspace among the groups studied. The understanding of TMC joint mobility under different age and gender conditions is achieved through this study. The findings can be used to report clinical measures in the determination of the extent of impairment of osteoarthritis as well as the outcomes between pre- and post-surgical (or non-surgical) interventions.