Back to Authors

Berglund, Lars

https://orcid.org/0000-0002-0754-2182

Mayo Clinic

Mayo Clinic

Citations 5

Effect of the location of the split of the subscapularis on range of motion and stability of the glenohumeral joint following Latarjet or Trillat procedures
Nourissat, Geoffroy , Hooke, Alex, Berglund, Lars , Thoreson, Andrew R. , An, K-N, Werthel, J-D., Hooke, Alexander W. , An, K-N.

Orthopaedic Journal of Sports Medicine | May 30, 2019 | Volume: 7 | Issue: 5_suppl3 | Pages: No page available

10.1177/2325967119s00202 Get It

Aim: Compare the effect of Latarjet and Trillat procedures on glenohumeral stability and range of motion. Background: Little is known about the impact of the location of the sling effect on joint stability and range of motion. Methods: 12 cadaveric shoulders were cleaned of soft tissue except for the subscapularis, conjoined tendon, and anterior capsule. A custom-made apparatus generating anterior humeral translation and joint compression was used. The machine applied compression load in the medial direction. The subscapularis and conjoint tendon were loaded. Internal/external range of motion and joint stability were assessed at 0°, 30° and 60° glenohumeral abduction. Range of motion was assessed by rotating the humeral shaft. Joint stability was assessed at maximum external rotation, translating the humerus. Specimen were tested in five conditions: 1) intact shoulder, 2) 6-mm bony glenoid defect (20% defect) 3) Trillat procedure, 4) Latarjet procedure with subscapularis split at the junction between its superior 2/3rds and inferior 1/3 rd, 5) Latarjet procedure with subscapularis split at the superior 1/3rds and inferior 2/3rds. Means were compared with a full factorial-repeated measures ANOVA with pairwise post hoc comparisons. Results: Peak translation force and stability ratio were significantly lower with the glenoid defect when compared to the intact and all the repaired conditions at all levels of glenohumeral abduction. The level of the subscapularis split had no significant influence on these values and no significant difference could be found between Trillat and Latarjet procedures. Range of motion in internal and external rotation were not significantly different between the different conditions. Conclusions: Joint stability and range of motion after a Latarjet are not impacted by the location of the subscapularis muscle split. Trillat and Latarjet techniques provide comparable stabilization of the joint, even in the presence of a critical bony defect of the glenoid.
Biomechanical comparison of three fixation techniques used for four-corner arthrodesis
Kraisarin, Jirachart, Dennison, David G., Berglund, Lars , An, Kai‐Nan , Shin, Alexander Y. , Shin, Alexander Y

Journal of Hand Surgery (European Volume) | June 3, 2011 | Volume: 36 | Issue: 7 | Pages: 560-567

10.1177/1753193411406799 Get It

Clinical results following four-corner arthrodesis vary and suggest that nonunion may be related to certain fixation techniques. The purpose of our study was to examine the displacement between the lunate and capitate following a simulated four-corner arthrodesis with the hypothesis that three types of fixation (Kirschner wires, dorsal circular plate, and a locked dorsal circular plate) would allow different amounts of displacement during simulated wrist flexion and extension. Cadaver wrists with simulated four-corner arthrodeses were loaded cyclically either to implant failure or until the lunocapitate displacement exceeded 1 mm. The locked dorsal circular plate group was significantly more stable than the dorsal circular plate and K-wire groups ( p = 0.018 and p = 0.006). While these locked dorsal circular plates appear to be very stable our results are limited only to the biomechanical behavior of these fixation techniques within a cadaver model.
The Effect of Radioscapholunate Fusion On Wrist Movement and the Subsequent Effects of Distal Scaphoidectomy and Triquetrectomy
Berkhout, Merel J.-L. , Shaw, Miranda N., Berglund, Lars , An, Kai‐Nan , Berger, Richard A. , Ritt, Marco J.P.F.

Journal of Hand Surgery (European Volume) | April 28, 2010 | Volume: 35 | Issue: 9 | Pages: 740-745

10.1177/1753193410370926 Get It

Radioscapholunate arthrodesis is a salvage procedure indicated for osteoarthritis of the radiocarpal joint involving the lunate facet of the radius. This cadaver study examines changes in wrist motion resulting from radioscapholunate arthrodesis, and the effects of surgical techniques to improve the range of motion. Simulated radioscapholunate arthrodesis, distal scaphoidectomy and triquetrectomy were carried out sequentially on six cadaver forearms and measurements (maximum flexion/extension and radial/ulnar deviation) were taken in the intact situation and after each surgical step using a magnetic tracking device. Radioscapholunate arthrodesis diminishes the amplitudes of movements of the wrist in all directions, but range of motion in the radioscapholunate fused wrist improves after scaphoidectomy and improves further after triquetrectomy (88% of original flexion/extension and 98% of original radial/ulnar deviation). Radioscapholunate arthrodesis causes a significant change in kinematics between the hamate and the triquetrum in flexion/extension.
An Instrumented Wheel for Kinetic Analysis of Wheelchair Propulsion
Berglund, Lars , Su, Fong‐Chin , Yu, Bin , Westreich, A., Wu, Hong Wen , Kim, Kee Joo , An, Ke

Journal of Biomechanical Engineering | February 21, 2008 | Volume: 120 | Issue: 4 | Pages: 533-535

10.1115/1.2798024 Get It

An instrumented wheel system for three-dimensional kinetic analysis of upper extremity during wheelchair propulsion has been designed and validated. This system allows the direct measurements of three-dimensional dynamic forces and moments on the handrim during wheelchair propulsion in a laboratory setting as well as in the field. Static loading tests showed a high linearity and little drift (coefficient of determination, r2 > 0.999). Under dynamic loading, the instrumented wheel provided the well-matched measurement forces and moments with the predicted values from the inverse dynamic method using video-based kinematic data (correlation coefficient, ρ > 0.97). The three-dimensional handrim forces and moments during wheelchair propulsion by a non-disabled subject were demonstrated.
“Physiological” Tensions of the Ulnar Nerve with Limb Positioning
Khoo, David Boo-Aun, Shih, Jim-Shown, Berglund, Lars , Wood, Michael B., An, Kai‐Nan

Journal of Hand Surgery | June 17, 2005 | Volume: 19 | Issue: 1_suppl | Pages: 15-15

10.1016/0266-7681(94)90312-3 Get It