Back to Authors

An, K-N

Mayo Clinic

Mayo Clinic

Citations 5

Biological analysis of flexor tendon repair-failure stump tissue: a potential recycling of tissue for tendon regeneration
Lu, Cheng‐Chang , Zhang, T., Reisdorf, Ramona L., Amadio, Peter C. , An, K-N, Moran, Steven L. , Gingery, Anne , Zhao, Chunfeng , An, K-N., Gingery, Anne

Bone & Joint Research | June 14, 2019 | Volume: 8 | Issue: 6 | Pages: 232-245

10.1302/2046-3758.86.bjr-2018-0239.r1 Get It

Objectives Re-rupture is common after primary flexor tendon repair. Characterization of the biological changes in the ruptured tendon stumps would be helpful, not only to understand the biological responses to the failed tendon repair, but also to investigate if the tendon stumps could be used as a recycling biomaterial for tendon regeneration in the secondary grafting surgery. Methods A canine flexor tendon repair and failure model was used. Following six weeks of repair failure, the tendon stumps were analyzed and characterized as isolated tendon-derived stem cells (TDSCs). Results Failed-repair stump tissue showed cellular accumulation of crumpled and disoriented collagen fibres. Compared with normal tendon, stump tissue had significantly higher gene expression of collagens I and III, matrix metalloproteinases (MMPs), vascular endothelial growth factor (VEGF), platelet-derived growth factor (PDGF), and insulin-like growth factor (IGF). The stump TDSCs presented both mesenchymal stem and haematopoietic cell markers with significantly increased expression of CD34, CD44, and CD90 markers. Stump TDSCs exhibited similar migration but a lower proliferation rate, as well as similar osteogenic differentiation but a lower chondrogenic/adipogenic differentiation capability, compared with normal TDSCs. Stump TDSCs also showed increasing levels of SRY-box 2 (Sox2), octamer-binding transcription factor 4 (Oct4), tenomodulin (TNMD), and scleraxis (Scx) protein and gene expression. Conclusion We found that a failed repair stump had increased cellularity that preserved both mesenchymal and haematopoietic stem cell characteristics, with higher collagen synthesis, MMP, and growth factor gene expression. This study provides evidence that tendon stump tissue has regenerative potential. Cite this article: C-C. Lu, T. Zhang, R. L. Reisdorf, P. C. Amadio, K-N. An, S. L. Moran, A. Gingery, C. Zhao. Biological analysis of flexor tendon repair-failure stump tissue: A potential recycling of tissue for tendon regeneration. Bone Joint Res 2019;8:232–245. DOI: 10.1302/2046-3758.86.BJR-2018-0239.R1.
Effect of the location of the split of the subscapularis on range of motion and stability of the glenohumeral joint following Latarjet or Trillat procedures
Nourissat, Geoffroy , Hooke, Alex, Berglund, Lars , Thoreson, Andrew R. , An, K-N, Werthel, J-D., Hooke, Alexander W. , An, K-N.

Orthopaedic Journal of Sports Medicine | May 30, 2019 | Volume: 7 | Issue: 5_suppl3 | Pages: No page available

10.1177/2325967119s00202 Get It

Aim: Compare the effect of Latarjet and Trillat procedures on glenohumeral stability and range of motion. Background: Little is known about the impact of the location of the sling effect on joint stability and range of motion. Methods: 12 cadaveric shoulders were cleaned of soft tissue except for the subscapularis, conjoined tendon, and anterior capsule. A custom-made apparatus generating anterior humeral translation and joint compression was used. The machine applied compression load in the medial direction. The subscapularis and conjoint tendon were loaded. Internal/external range of motion and joint stability were assessed at 0°, 30° and 60° glenohumeral abduction. Range of motion was assessed by rotating the humeral shaft. Joint stability was assessed at maximum external rotation, translating the humerus. Specimen were tested in five conditions: 1) intact shoulder, 2) 6-mm bony glenoid defect (20% defect) 3) Trillat procedure, 4) Latarjet procedure with subscapularis split at the junction between its superior 2/3rds and inferior 1/3 rd, 5) Latarjet procedure with subscapularis split at the superior 1/3rds and inferior 2/3rds. Means were compared with a full factorial-repeated measures ANOVA with pairwise post hoc comparisons. Results: Peak translation force and stability ratio were significantly lower with the glenoid defect when compared to the intact and all the repaired conditions at all levels of glenohumeral abduction. The level of the subscapularis split had no significant influence on these values and no significant difference could be found between Trillat and Latarjet procedures. Range of motion in internal and external rotation were not significantly different between the different conditions. Conclusions: Joint stability and range of motion after a Latarjet are not impacted by the location of the subscapularis muscle split. Trillat and Latarjet techniques provide comparable stabilization of the joint, even in the presence of a critical bony defect of the glenoid.
Stabilising function of the biceps in stable and unstable shoulders
Itoi, Eiji, Kuechle, DK, Newman, Morrey, BF, An, K-N, An, K-N.

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 75-B | Issue: 4 | Pages: 546-550

10.1302/0301-620x.75b4.8331107 Get It

We studied the contributions of the long and short heads of the biceps (LHB, SHB) to anterior stability in 13 cadaver shoulders. The LHB and SHB were replaced by spring devices and translation tests at 90 degrees abduction of the arm were performed by applying a 1.5 kg anterior force. The position of the humeral head was monitored by an electromagnetic tracking device with or without an anterior translational force; with 0 kg, 1.5 kg or 3 kg loads applied on either LHB or SHB tendons in 60 degrees, 90 degrees or 120 degrees of external rotation; and with the capsule intact, vented, or damaged by a Bankart lesion. The anterior displacement of the humeral head under 1.5 kg force was significantly decreased by both the LHB and SHB loading in all capsular conditions when the arm was in 60 degrees or 90 degrees of external rotation. At 120 degrees of external rotation, anterior displacement was significantly decreased by LHB and SHB loading only when there was a Bankart lesion. We conclude that LHB and SHB have similar functions as anterior stabilizers of the glenohumeral joint with the arm in abduction and external rotation, and that their role increases as shoulder stability decreases. Both heads of the biceps have been shown to have a stabilising function in resisting anterior head displacement, and consideration should therefore be given to strengthening the biceps during rehabilitation programmes for chronic anterior instability of the shoulder.
Biomechanical analysis of the effect of congruence, depth and radius on the stability ratio of a simplistic ‘ball-and-socket’ joint model
Werthel, J-D., Thoreson, Andrew R. , Resch, Herbert, An, K-N, Moroder, Philipp , Ernstbrunner, Lukas , Werthel, J.D., Hatta, Taku , An, K-N.

Bone & Joint Research | October 12, 2016 | Volume: 5 | Issue: 10 | Pages: 453-460

10.1302/2046-3758.510.bjr-2016-0078.r1 Get It

ObjectivesThe bony shoulder stability ratio (BSSR) allows for quantification of the bony stabilisers in vivo. We aimed to biomechanically validate the BSSR, determine whether joint incongruence affects the stability ratio (SR) of a shoulder model, and determine the correct parameters (glenoid concavity versus humeral head radius) for calculation of the BSSR in vivo.MethodsFour polyethylene balls (radii: 19.1 mm to 38.1 mm) were used to mould four fitting sockets in four different depths (3.2 mm to 19.1mm). The SR was measured in biomechanical congruent and incongruent experimental series. The experimental SR of a congruent system was compared with the calculated SR based on the BSSR approach. Differences in SR between congruent and incongruent experimental conditions were quantified. Finally, the experimental SR was compared with either calculated SR based on the socket concavity or plastic ball radius.ResultsThe experimental SR is comparable with the calculated SR (mean difference 10%, sd 8%; relative values). The experimental incongruence study observed almost no differences (2%, sd 2%). The calculated SR on the basis of the socket concavity radius is superior in predicting the experimental SR (mean difference 10%, sd 9%) compared with the calculated SR based on the plastic ball radius (mean difference 42%, sd 55%).ConclusionThe present biomechanical investigation confirmed the validity of the BSSR. Incongruence has no significant effect on the SR of a shoulder model. In the event of an incongruent system, the calculation of the BSSR on the basis of the glenoid concavity radius is recommended. Cite this article: L. Ernstbrunner, J-D. Werthel, T. Hatta, A. R. Thoreson, H. Resch, K-N. An, P. Moroder. Biomechanical analysis of the effect of congruence, depth and radius on the stability ratio of a simplistic ‘ball-and-socket’ joint model. Bone Joint Res 2016;5:453–460. DOI: 10.1302/2046-3758.510.BJR-2016-0078.R1.
Prosthesis Design and Stress Profile after Hip Resurfacing: A Finite Element Analysis
Heijink, Andras, Zobitz, M. E., Nuyts, Rudy M. M. A., Morrey, BF, An, K-N, Morrey, BF, An, K-N.

Journal of Orthopaedic Surgery | October 4, 2016 | Volume: 16 | Issue: 3 | Pages: 326-332

10.1177/230949900801600312 Get It

Purpose. To evaluate the effect of prosthesis design on stress profile in the proximal femur after hip resurfacing. Methods. The von Mises stress profile of the native femur was simulated and compared with that of resurfaced femurs using various prosthetic materials (titanium, cobalt-chrome, ceramic), stem lengths (normal, half, short, and no stem), and femoral head coverage (shell size) [260°, 220°, 180°, and 140°]. Results. Hip resurfacing altered the stress profile of the cancellous (but not cortical) bone of the femoral neck. Maximal cortical stresses were observed at the posterior half of the medial femoral neck. The stress profile of the native femur was most similar to that of the resurfaced femur made of titanium, with a short or no stem and 260 degrees of femoral head coverage (shell size). Conclusion. Optimising prosthesis design by minimising biomechanical alterations seems a valid approach to achieving favourable long-term outcomes. Cadaveric and in vivo studies are needed to confirm the clinical relevance and feasibility.