Back to Authors

Morrey, BF

Mayo Clinic

Mayo Clinic

Citations 2

Kinematics of semi-constrained total elbow arthroplasty
An, K-N., Korinek, Sarah, Morrey, BF, O’Driscoll, Shawn W. , Morrey, BF

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 74-B | Issue: 2 | Pages: 297-299

10.1302/0301-620x.74b2.1544973 Get It

We used 11 cadaver elbows and a three-dimensional electromagnetic tracking device to record elbow movements before and after implantation of a 'loose-hinged' elbow prosthesis (modified Coonrad). During simulated active motion there was a maximum of 2.7 degrees (+/- 1.5 degrees) varus/valgus laxity in the cadaver joints. This increased slightly after total elbow arthroplasty to 3.8 degrees (+/- 1.4 degrees). These values are lower than those recorded for the cadaver joints and for the prostheses at the limits of their varus/valgus displacements, indicating that both behave as 'semi-constrained' joints under physiological conditions. They suggest that the muscles absorb some of the forces and moments that in a constrained prosthesis would be transferred to the prosthesis-bone interface.
Prosthesis Design and Stress Profile after Hip Resurfacing: A Finite Element Analysis
Heijink, Andras, Zobitz, M. E., Nuyts, Rudy M. M. A., Morrey, BF, An, K-N, Morrey, BF, An, K-N.

Journal of Orthopaedic Surgery | October 4, 2016 | Volume: 16 | Issue: 3 | Pages: 326-332

10.1177/230949900801600312 Get It

Purpose. To evaluate the effect of prosthesis design on stress profile in the proximal femur after hip resurfacing. Methods. The von Mises stress profile of the native femur was simulated and compared with that of resurfaced femurs using various prosthetic materials (titanium, cobalt-chrome, ceramic), stem lengths (normal, half, short, and no stem), and femoral head coverage (shell size) [260°, 220°, 180°, and 140°]. Results. Hip resurfacing altered the stress profile of the cancellous (but not cortical) bone of the femoral neck. Maximal cortical stresses were observed at the posterior half of the medial femoral neck. The stress profile of the native femur was most similar to that of the resurfaced femur made of titanium, with a short or no stem and 260 degrees of femoral head coverage (shell size). Conclusion. Optimising prosthesis design by minimising biomechanical alterations seems a valid approach to achieving favourable long-term outcomes. Cadaveric and in vivo studies are needed to confirm the clinical relevance and feasibility.