Morrey, BF

Mayo Clinic

Mayo Clinic

Citations 9

Total replacement for post-traumatic arthritis of the elbow
Morrey, BF, Adams, RA, Bryan, RS

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 73-B | Issue: 4 | Pages: 607-612

10.1302/0301-620x.73b4.2071644 Get It

Fifty-three of 55 consecutive elbow replacements for post-traumatic arthritis were followed for a minimum of two years (mean 6.3, range 2 to 14.4). The patients presented difficult management problems, having undergone an average of two previous operations per joint; 22 joints had suffered prior complications; 18 had less than 50 degrees of flexion and six were flail. One of three versions of the Coonrad prosthesis was employed in all. During the follow-up period, 10 patients underwent 14 revision procedures for aseptic loosening; 38 elbows are currently without progressive radiolucent lines. In two patients an elbow had to be resected, one for deep infection and the other for bone resorption following a foreign-body reaction to titanium. The current design of the Coonrad prosthesis offers a reliable option for the treatment of post-traumatic arthritis but should be used only in carefully selected patients over the age of 60 years.
Kinematics of semi-constrained total elbow arthroplasty
An, K-N., Korinek, Sarah, Morrey, BF, O’Driscoll, Shawn W. , Morrey, BF

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 74-B | Issue: 2 | Pages: 297-299

10.1302/0301-620x.74b2.1544973 Get It

We used 11 cadaver elbows and a three-dimensional electromagnetic tracking device to record elbow movements before and after implantation of a 'loose-hinged' elbow prosthesis (modified Coonrad). During simulated active motion there was a maximum of 2.7 degrees (+/- 1.5 degrees) varus/valgus laxity in the cadaver joints. This increased slightly after total elbow arthroplasty to 3.8 degrees (+/- 1.4 degrees). These values are lower than those recorded for the cadaver joints and for the prostheses at the limits of their varus/valgus displacements, indicating that both behave as 'semi-constrained' joints under physiological conditions. They suggest that the muscles absorb some of the forces and moments that in a constrained prosthesis would be transferred to the prosthesis-bone interface.
Stabilising function of the biceps in stable and unstable shoulders
Itoi, Eiji, Kuechle, DK, Newman, Morrey, BF, An, K-N, An, K-N.

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 75-B | Issue: 4 | Pages: 546-550

10.1302/0301-620x.75b4.8331107 Get It

We studied the contributions of the long and short heads of the biceps (LHB, SHB) to anterior stability in 13 cadaver shoulders. The LHB and SHB were replaced by spring devices and translation tests at 90 degrees abduction of the arm were performed by applying a 1.5 kg anterior force. The position of the humeral head was monitored by an electromagnetic tracking device with or without an anterior translational force; with 0 kg, 1.5 kg or 3 kg loads applied on either LHB or SHB tendons in 60 degrees, 90 degrees or 120 degrees of external rotation; and with the capsule intact, vented, or damaged by a Bankart lesion. The anterior displacement of the humeral head under 1.5 kg force was significantly decreased by both the LHB and SHB loading in all capsular conditions when the arm was in 60 degrees or 90 degrees of external rotation. At 120 degrees of external rotation, anterior displacement was significantly decreased by LHB and SHB loading only when there was a Bankart lesion. We conclude that LHB and SHB have similar functions as anterior stabilizers of the glenohumeral joint with the arm in abduction and external rotation, and that their role increases as shoulder stability decreases. Both heads of the biceps have been shown to have a stabilising function in resisting anterior head displacement, and consideration should therefore be given to strengthening the biceps during rehabilitation programmes for chronic anterior instability of the shoulder.
Upper tibial osteotomy for secondary osteoarthritis of the knee
Morrey, BF

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 71-B | Issue: 4 | Pages: 554-559

10.1302/0301-620x.71b4.2768296 Get It

Of 34 consecutive proximal tibial osteotomies for secondary degenerative arthritis in patients under 40 years of age, 33 were evaluated at least three years (mean 7.5 years) after operation. In all 73% were satisfactory, with four failures in 21 procedures in men and five failures in 12 procedures in women. The primary abnormalities were medial meniscectomy (11), medial and lateral meniscectomy (4), osteochondritis dissecans (3), osteochondritis dissecans with medial meniscectomy (4) and fracture (11). All four knees with both medial and lateral meniscectomy had unsatisfactory results despite obtaining anatomical alignment. Eight patients needed subsequent surgery; five of them had total knee replacement, four within four years of the osteotomy. Proximal tibial osteotomy in younger patients with secondary arthritis gives similar results to those for older patients with primary osteoarthritis. If it fails, this is generally within the first four years after the operation.
Glenohumeral elevation studied in three dimensions
Browne, AO, Tanaka, Shinji , An, K-N., Morrey, BF, Hoffmeyer, Pierre

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 72-B | Issue: 5 | Pages: 843-845

10.1302/0301-620x.72b5.2211768 Get It

We studied the position and rotational changes associated with elevation of the glenohumeral joint, using a three-dimensional magnetic-field tracking system on nine fresh cadaveric shoulders. The plane of maximal arm elevation was shown to occur 23 degrees anterior to the plane of the scapula. Elevation in any plane anterior to the scapula required external humeral rotation, and maximal elevation was associated with approximately 35 degrees of external humeral rotation. Conversely, internal rotation was necessary for increased elevation posterior to the plane of the scapula. The observed effects of this rotation were to clear the humeral tuberosity from abutting beneath the acromion and to relax the inferior capsular ligamentous constraints. Measurement of the obligatory humeral rotation required for maximal elevation helps to explain the relationship of the limited elevation seen in adhesive capsulitis and after operations which limit external rotation.
The cubital tunnel and ulnar neuropathy
Horii, Emiko , Carmichael, S., Morrey, BF, O’Driscoll, Shawn W.

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 73-B | Issue: 4 | Pages: 613-617

10.1302/0301-620x.73b4.2071645 Get It

The anatomy of the cubital tunnel and its relationship to ulnar nerve compression is not well documented. In 27 cadaver elbows the proximal edge of the roof of the cubital tunnel was formed by a fibrous band that we call the cubital tunnel retinaculum (CTR). The band is about 4 mm wide, extending from the medial epicondyle to the olecranon, and perpendicular to the flexor carpi ulnaris aponeurosis. Variations in the CTR were classified into four types. In type 0 (n = 1) the CTR was absent. In type Ia (n = 17), the retinaculum was lax in extension and taut in full flexion. In type Ib (n = 6) it was tight in positions short of full flexion (90 degrees to 120 degrees). In type II (n = 3) it was replaced by a muscle, the anconeus epitrochlearis. The CTR appears to be a remnant of the anconeus epitrochlearis muscle and its function is to hold the ulnar nerve in position. Variations in the anatomy of the CTR may explain certain types of ulnar neuropathy. Its absence (type 0 CTR) permits ulnar nerve displacement. Type Ia is normal and does not cause ulnar neuropathy. Type Ib can cause dynamic nerve compression with elbow flexion. Type II may be associated with static compression due to the bulk of the anconeus epitrochlearis muscle.
Primary degenerative arthritis of the elbow. Treatment by ulnohumeral arthroplasty
Morrey, BF

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 74-B | Issue: 3 | Pages: 409-413

10.1302/0301-620x.74b3.1587890 Get It

Degenerative arthritis of the elbow is a poorly recognised condition, usually seen in a middle-aged man with an occupation or activity which involves the repetitive use of his dominant arm. Flexion contracture and pain at terminal extension are common presenting features. Fifteen patients were reviewed at a mean of 33 months after debridement by ulnohumeral arthroplasty. Fourteen had good relief of pain, elbow extension had improved by an average of 11 degrees and elbow flexion by 10 degrees. On an objective scale 12 of the 15 patients had good or excellent results and 13 (87%) felt that they were improved by the operation.
Prosthesis Design and Stress Profile after Hip Resurfacing: A Finite Element Analysis
Heijink, Andras, Zobitz, M. E., Nuyts, Rudy M. M. A., Morrey, BF, An, K-N, Morrey, BF, An, K-N.

Journal of Orthopaedic Surgery | October 4, 2016 | Volume: 16 | Issue: 3 | Pages: 326-332

10.1177/230949900801600312 Get It

Purpose. To evaluate the effect of prosthesis design on stress profile in the proximal femur after hip resurfacing. Methods. The von Mises stress profile of the native femur was simulated and compared with that of resurfaced femurs using various prosthetic materials (titanium, cobalt-chrome, ceramic), stem lengths (normal, half, short, and no stem), and femoral head coverage (shell size) [260°, 220°, 180°, and 140°]. Results. Hip resurfacing altered the stress profile of the cancellous (but not cortical) bone of the femoral neck. Maximal cortical stresses were observed at the posterior half of the medial femoral neck. The stress profile of the native femur was most similar to that of the resurfaced femur made of titanium, with a short or no stem and 260 degrees of femoral head coverage (shell size). Conclusion. Optimising prosthesis design by minimising biomechanical alterations seems a valid approach to achieving favourable long-term outcomes. Cadaveric and in vivo studies are needed to confirm the clinical relevance and feasibility.
The contribution of the coronoid and radial head to the stability of the elbow
Jeon, In‐Ho , Zhao, Kristin D. , An, Kai‐Nan , Morrey, BF, Sánchez‐Sotelo, Joaquín , Trentadue, Taylor P

The Journal of Bone and Joint Surgery. British volume | January 4, 2012 | Volume: 94-B | Issue: 1 | Pages: 86-92

10.1302/0301-620x.94b1.26530 Get It

We undertook this study to determine the minimum amount of coronoid necessary to stabilise an otherwise intact elbow joint. Regan–Morrey types II and III, plus medial and lateral oblique coronoid fractures, collectively termed type IV fractures, were simulated in nine fresh cadavers. An electromagnetic tracking system defined the three-dimensional stability of the ulna relative to the humerus. The coronoid surface area accounts for 59% of the anterior articulation. Alteration in valgus, internal and external rotation occurred only with a type III coronoid fracture, accounting for 68% of the coronoid and 40% of the entire articular surface. A type II fracture removed 42% of the coronoid articulation and 25% of the entire articular surface but was associated with valgus and external rotational changes only when the radial head was removed, thereby removing 67% of the articular surface. We conclude that all type III fractures, as defined here, are unstable, even with intact ligaments and a radial head. However, a type II deficiency is stable unless the radial head is removed. Our study suggests that isolated medial-oblique or lateral-oblique fractures, and even a type II fracture with intact ligaments and a functional radial head, can be clinically stable, which is consistent with clinical observation.