Back to Authors

Lu, Cheng‐Chang

https://orcid.org/0000-0002-7194-9147

Mayo Clinic

Kaohsiung Medical University

Citations 4

Bone marrow stromal and anterior cruciate ligament remnant cell co‐culture‐derived extracellular vesicles promote cell activity in both cell types
Wu, Shun Cheng, Liu, Zi‐Miao , Chou, Paul Pei‐Hsi , Zhao, Chunfeng , Lin, Sung-Yen , Ho, Mei‐Ling , Lu, Cheng‐Chang

Journal of Cellular and Molecular Medicine | September 1, 2024 | Volume: 28 | Issue: 17 | Pages: No page available

10.1111/jcmm.70049 Get It

Abstract The significance of anterior cruciate ligament (ACL) remnants during reconstruction remains unclear. Co‐culturing ACL remnant cells and bone marrow stromal cells (BMSCs) may reduce apoptosis and enhance hamstring tendon activity. This study investigated whether extracellular vesicles (EVs), which facilitate cell–cell interactions, act as the active components, improving graft maturation in this co‐culture. The effects of EVs on cell viability, proliferation, migration and gene expression in the rabbit ACL remnant cells and BMSCs were assessed using control (BMSC‐only culture), co‐culture (ACL remnant cells and BMSCs, CM) and co‐culture without EVs (CM ∆ EVs) media. EVs were isolated from control (BMSC‐EV) and co‐culture (CM‐EV) media and characterized. CM significantly enhanced the proliferation, migration and expression of transforming growth factor ( TGF‐β )‐, vascular endothelial growth factor ( VEGF )‐, collagen synthesis‐ and tenogenesis‐related genes. However, CM‐induced effects were reversed by the CM ∆ EVs treatment. CM‐EV treatment exhibited higher potential to enhance proliferation, migration and gene expression in the ACL remnant cells and BMSCs than BMSC‐EV and non‐EV treatments. In conclusion, EVs, secreted under the coexistence of ACL remnant cells and BMSCs, primarily increase the cell viability, proliferation, migration and gene expression of collagen synthesis‐, TGF‐β ‐, VEGF ‐ and tenogenesis‐related genes in both cell types.
Biological analysis of flexor tendon repair-failure stump tissue: a potential recycling of tissue for tendon regeneration
Lu, Cheng‐Chang , Zhang, T., Reisdorf, Ramona L., Amadio, Peter C. , An, K-N, Moran, Steven L. , Gingery, Anne , Zhao, Chunfeng , An, K-N., Gingery, Anne

Bone & Joint Research | June 14, 2019 | Volume: 8 | Issue: 6 | Pages: 232-245

10.1302/2046-3758.86.bjr-2018-0239.r1 Get It

Objectives Re-rupture is common after primary flexor tendon repair. Characterization of the biological changes in the ruptured tendon stumps would be helpful, not only to understand the biological responses to the failed tendon repair, but also to investigate if the tendon stumps could be used as a recycling biomaterial for tendon regeneration in the secondary grafting surgery. Methods A canine flexor tendon repair and failure model was used. Following six weeks of repair failure, the tendon stumps were analyzed and characterized as isolated tendon-derived stem cells (TDSCs). Results Failed-repair stump tissue showed cellular accumulation of crumpled and disoriented collagen fibres. Compared with normal tendon, stump tissue had significantly higher gene expression of collagens I and III, matrix metalloproteinases (MMPs), vascular endothelial growth factor (VEGF), platelet-derived growth factor (PDGF), and insulin-like growth factor (IGF). The stump TDSCs presented both mesenchymal stem and haematopoietic cell markers with significantly increased expression of CD34, CD44, and CD90 markers. Stump TDSCs exhibited similar migration but a lower proliferation rate, as well as similar osteogenic differentiation but a lower chondrogenic/adipogenic differentiation capability, compared with normal TDSCs. Stump TDSCs also showed increasing levels of SRY-box 2 (Sox2), octamer-binding transcription factor 4 (Oct4), tenomodulin (TNMD), and scleraxis (Scx) protein and gene expression. Conclusion We found that a failed repair stump had increased cellularity that preserved both mesenchymal and haematopoietic stem cell characteristics, with higher collagen synthesis, MMP, and growth factor gene expression. This study provides evidence that tendon stump tissue has regenerative potential. Cite this article: C-C. Lu, T. Zhang, R. L. Reisdorf, P. C. Amadio, K-N. An, S. L. Moran, A. Gingery, C. Zhao. Biological analysis of flexor tendon repair-failure stump tissue: A potential recycling of tissue for tendon regeneration. Bone Joint Res 2019;8:232–245. DOI: 10.1302/2046-3758.86.BJR-2018-0239.R1.
Revitalized and synovialized allograft for intrasynovial flexor tendon reconstruction in an in vivo canine model
Zhang, Tao , Lu, Cheng‐Chang , Reisdorf, Ramona L., Thoreson, Andrew R. , Gingery, Anne , Moran, Steven L. , Amadio, Peter C. , Zhao, Chunfeng , Gingery, Anne

Journal of Orthopaedic Research | August 22, 2018 | Volume: 36 | Issue: 8 | Pages: 2218-2227

10.1002/jor.23889 Get It

ABSTRACTThis study was to test our hypothesis that flexor tendon reconstruction with an allograft revitalized with bone marrow stromal cells (BMSCs) and synovialized with carbodiimide derivatized autologous synovial fluid (cd‐SYN) would result in better digit functional restoration than the conventional allograft tendon. A total of 32 flexor digital profundus tendons from the second and fifth digit of 16 dogs were created a repair failure model first. Then, failed‐repaired tendons were reconstructed with either a revitalized‐synovialized allograft tendon or a clinical standard autograft tendon (control group). The allograft tendon was seeded with autologous BMSCs in multiple slits and the graft surface was coated with cd‐SYN. A 6 weeks after tendon reconstruction, the digits were harvested and evaluated for digit function, adhesion status, tendon gliding resistance, attachment strength, cell viability, and histologic factors. The allograft group had significantly improved digit function compared with the control group through decreased work of flexion, increased digit range of motion under 2‐Newton force, and less adhesion score (p < .05). However, the distal attachment‐site strength and stiffness in the allograft tendon were significantly weaker than the autografts (p < .05). No significant difference was found for gliding resistance. Histologically, allograft tendons coated with allograft had smoother surfaces and showed tendon‐to‐bone and tendon‐to‐tendon incorporation. Viable BMSCs were found in the tendon slits 6 weeks after the graft. In conclusion, cellular lubricant‐based modification of allograft tendons improved digit function and reduced the adhesions compared with autograft for flexor tendon reconstruction. However, improvement of graft‐to‐host tendon healing is still challenging. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2218–2227, 2018.
Rotator cuff repair with a novel mesh suture: An ex vivo assessment of mechanical properties
Zhang, Tao , Thoreson, Andrew R. , Lu, Cheng‐Chang , Steinmann, Scott P. , Moran, Steven L. , Zhao, Chunfeng , Hatta, Taku, Lu, ChengChang, Hatta, Taku

Journal of Orthopaedic Research | August 1, 2017 | Volume: 36 | Issue: 3 | Pages: 987-992

10.1002/jor.23668 Get It

ABSTRACTSurgical repair is a common treatment for rotator cuff tear; however, the retear rate is high. A high degree of suture repair strength is important to ensure rotator cuff integrity for healing. The purpose of this study was to compare the mechanical performance of rotator cuffs repaired with a mesh suture versus traditional polydioxanone suture II and FiberWire sutures in a canine in vitro model. Seventy‐two canine shoulders were harvested. An infraspinatus tendon tear was created in each shoulder. Two suture techniques—simple interrupted sutures and two‐row suture bridge—were used to reconnect the infraspinatus tendon to the greater tuberosity, using three different suture types: Mesh suture, polydioxanone suture II, or FiberWire. Shoulders were loaded to failure under displacement control at a rate of 20 mm/min. Failure load was compared between suture types and techniques. Ultimate failure load was significantly higher in the specimens repaired with mesh suture than with polydioxanone suture II or FiberWire, regardless of suture technique. There was no significant difference in stiffness among the six groups, with the exception that FiberWire repairs were stiffer than polydioxanone suture II repairs with the simple interrupted technique. All specimens failed by suture pull‐out from the tendon. Based on our biomechanical findings, rotator cuff repair with the mesh suture might provide superior initial strength against failure compared with the traditional polydioxanone suture II or FiberWire sutures. Use of the mesh suture may provide increased initial fixation strength and decrease gap formation, which could result in improved healing and lower re‐tear rates following rotator cuff repair. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:987–992, 2018.