Back to Authors

Cooney, W.P.

Mayo Clinic

Mayo Clinic

Citations 9

Herbert screw fixation of scaphoid fractures
Cooney, W.P.

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 80-B | Issue: 1 | Pages: 181-181

10.1302/0301-620x.80b1.0800181c Get It

Effects of age and gender on the movement workspace of the trapeziometacarpal joint
Kuo, L-C, Cooney, W.P., An, K-N., Lai, K.Y., Wang, S-M, Su, Fong‐Chin , Kuo, Li‐Chieh , Kuo, L-C, Wang, S-M

Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | December 12, 2008 | Volume: 223 | Issue: 2 | Pages: 133-142

10.1243/09544119jeim489 Get It

While researchers have suggested that joint mobility would probably be affected by age and gender, research findings often present discrepancies. Little research has been performed on the factors which effect mobility of the trapeziometacarpal (TMC) joint. The purpose of this study was to address the effects of age and gender on the ranges of motion of the normal TMC joint. Eighty normal subjects divided into four age groups participated in this study. The TMC joint motions were recorded using an electromagnetic tracking system. In order to achieve a maximal range of TMC joint motion which was defined as the maximal workspace, each subject was asked to perform actively maximal circumduction, flexion—extension, and abduction—adduction of the TMC joint. Numerical and statistical methods were used to compute the TMC workspace and to detect significant differences. A workspace-to-length ratio was determined as an index to examine the effects of the age and gender on the joint mobility. The results demonstrated that age and gender had significant influences on the TMC workspace among the groups studied. The understanding of TMC joint mobility under different age and gender conditions is achieved through this study. The findings can be used to report clinical measures in the determination of the extent of impairment of osteoarthritis as well as the outcomes between pre- and post-surgical (or non-surgical) interventions.
Lumbrical Muscle Incursion into the Carpal Tunnel During Finger Flexion
Cobb, Tyson K., Cooney, W.P., Berger, Ruth, An, Ke

Journal of Hand Surgery | June 17, 2005 | Volume: 19 | Issue: 4 | Pages: 434-438

10.1016/0266-7681(94)90206-2 Get It

Carpal tunnel syndrome is one of the many so-called cumulative trauma disorders thought by some to be related to the performance of repetitive tasks in the work-place. The cause of this disorder is unknown. We have observed lumbrical muscle incursion into the carpal tunnel during finger flexion. This study was conducted to determine the amount of this incursion in normal wrists. Five cadaver upper limbs were analyzed radiographically with radiopaque markers on the flexor retinaculum and the lumbrical muscle origins in four finger positions: full extension, 50% flexion, 75% flexion, and 100% finger flexion. The lumbrical muscle origins were an average of 7.8 mm distal to the carpal tunnel in full finger extension. They moved an average of 14 mm into the carpal tunnel with 50% finger flexion, 25.5 mm with 75% flexion, and 30 mm with 100% flexion. Abnormal lumbrical muscles have been cited as a possible cause of carpal tunnel syndrome. These findings suggest that lumbrical muscle incursion during finger flexion is a normal occurrence and is a possible cause of work-related carpal tunnel syndrome.
Significance of Incomplete Release of The Distal Portion of The Flexor Retinaculum
Cobb, Tyson K., Cooney, W.P.

Journal of Hand Surgery | June 17, 2005 | Volume: 19 | Issue: 3 | Pages: 283-285

10.1016/0266-7681(94)90070-1 Get It

Endoscopic carpal tunnel release has been shown in recent studies to result in a significant number of incomplete releases of the distal aspect of the flexor retinaculum. The significance of this complication is unknown. To address this question, we measured the amount of carpal arch widening after incomplete and complete release. The mean amount of change in carpal arch width in five cadaveric hands after partial release (all but the distal 4 mm) was 0.74 mm, which was statistically significant. The mean additional change after release of the remaining 4 mm of the flexor retinaculum was 0.12 mm, which was not significant. Incomplete release of the distal 4 mm of the distal aspect of the flexor retinaculum allows carpal arch widening that is no different from that of complete sectioning of the flexor retinaculum in the cadaver limb.
The Ulnar Neurovascular Bundle at the Wrist
Cobb, Tyson K., Carmichael, S., Cooney, W.P.

Journal of Hand Surgery | June 17, 2005 | Volume: 19 | Issue: 1 | Pages: 24-26

10.1016/0266-7681(94)90042-6 Get It

The boundaries of Guyon’s canal have recently been redefined by a series of anatomical dissections. These showed that the confines of this space do not extend from the pisiform to the hook of the hamate, as currently accepted. The fascial roof extends radial to the hook of the hamate, which allows the ulnar neurovascular bundle to course radial to the hamate hook. The position of the ulnar nerve and artery is of particular significance for endoscopic carpal tunnel release. Most endoscopic devices are designed to divide the flexor retinaculum just to the radial aspect of the hamate hook. Utilizing cross-sectional analysis of nine cadaver specimens, we found the ulnar artery to course radial to the hamate hook in five and palmar to it in four. Therefore, the ulnar artery may be at greater risk of injury during endoscopic procedures than previously recognized.
Mechanical Properties of Human Pulleys
Lin, G.T., Cooney, W.P., Amadio, Peter C. , An, Kai‐Nan

Journal of Hand Surgery | June 17, 2005 | Volume: 15 | Issue: 4 | Pages: 429-434

10.1016/0266-7681(90)90085-i Get It

In order to determine the mechanical properties of the fibro-osseous pulleys in the hand, the diaphyseal annular pulleys, the volar plate annular pulleys and the cruciate or condensable portions were tested. A custom-made loading device provided proper fit of the soft tissues for a uniform distribution of the pulley load during testing. The A2 pulley was found to be the strongest of the pulleys; the A1 and A4 were the next strongest. The A3 pulley was nearly equal in mean breaking strength to the other annular pulleys, but in absolute breaking load was considerably weaker because of its shortness. The A4 was the least compliant of the pulleys. We concluded that the fibro-osseous A2 and A4 were mechanically stronger and stiffer pulleys than the A1, A3, A5 (volar plate) pulleys. In testing one type of pulley reconstruction, we found that the “belt loop” technique of Karev nearly matched the annular pulleys in strength and energy absorption.
Arthroscopy of the wrist: Anatomy and classification of carpal instability
Cooney, W.P., Dobyns, James H., Linscheid, Ronald L.

Arthroscopy | April 22, 2004 | Volume: 6 | Issue: 2 | Pages: 133-140

10.1016/0749-8063(90)90014-5 Get It

Abstract Carpal instability can be defined as the lack of ligamentous and skeletal support adequate to maintain a wrist stable to external forces of pinch and grasp. This instability may be static or dynamic. It has been classified as (a) carpal instability, dissociated (CID), a situation in which one or more of the ligaments are torn, and (b) carpal instability, nondissociative (CIND), a situation in which the ligaments are intact but stretched. Carpal instability can also be the result of carpal bone malalignment from various causes. Arthroscopy can be particularly useful in assessing carpal instability, however arthrography with contrast medium, fluoroscopy, and stress loading should precede this arthroscopic assessment. Arthroscopy allows visualization of the volar radiocarpal and ulnocarpal ligaments of the wrist, and the arthroscopic examination can be combined with manual manipulation of the carpal bones to detect laxity of those ligaments, to examine stability of the scapholunate and lunotriquetral interosseous ligaments, and to show instability of the distal radioulnar joint.
A kinematic method to calculate the workspace of the trapeziometacarpal joint
Kuo, Li‐Chieh , Cooney, W.P., Chen, Qingshan , Kaufman, Kenton R. , Su, Fong‐Chin , An, Kai‐Nan, Kaufman, Kenton R

Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | April 6, 2004 | Volume: 218 | Issue: 2 | Pages: 143-149

10.1243/095441104322984031 Get It

The specific aim of this study was to develop a quantitative method and a kinematic method to evaluate the maximal workspace of the trapeziometacarpal (TM) joint. Six fresh-frozen human cadaver hands were disarticulated 4 cm proximal to the wrist joint and used in this experiment. The three-dimensional motion data of the TM joint was collected by an electromagnetic tracking device at 30 Hz. The workspace was reconstructed according to a complete set of motion data included circumduction, flexion-extension and abduction-adduction. A spherical fitting technique was used to obtain a sphere encompassing all the motion trajectories and estimating the centre of the sphere. The surface area of the maximal TM workspace, located on the one part of the sphere surface, was calculated by surface integration. The interclass correlation coefficient values for the reliability estimation of the repeated measurements of the radius and surface area of all specimens were 0.91 and 0.98 respectively. The mean coefficients of variance of the measured radius and the surface area were 2.04 per cent and 3.65 per cent respectively. The results also showed that using a spherical model to calculate the maximal workspace as an index for assessing TM joint impairment is practical.
Letters to the Editor
Cooney, W.P.

Journal of Hand Surgery | September 19, 2002 | Volume: 26 | Issue: 4 | Pages: 392-392

10.1054/jhsb.2001.0666 Get It