Back to Authors

Friedman, Paul A.

https://orcid.org/0000-0001-5052-2948

Mayo Clinic

Mayo Clinic

Citations 351

Artificial intelligence-enabled detection of paroxysmal atrial fibrillation from normal sinus ECGs in patients with coronary microvascular dysfunction
Ahmad, Ali , Cohen, M, Friedman, Paul A. , Corban, Michel , Toya, Takumi , Attia, Zachi I. , Noseworthy, Peter A. , López-Jiménez, Francisco , Kapa, Suraj , Lerman, Amir

European Heart Journal | November 26, 2020 | Volume: 41 | Issue: Supplement_2 | Pages: No page available

10.1093/ehjci/ehaa946.1265 Get It

Abstract Background Artificial Intelligence (AI) algorithms enabled the detection of patients with paroxysmal atrial fibrillation (PAF) from a single normal sinus rhythm (NSR) ECG. Coronary microvascular dysfunction (CMD) is a precursor for coronary artery disease, which is a known risk factor for AF. Purpose The aim of this study is to examine the probability of PAF, according to AI-enabled algorithm estimation, in patients with CMD. Methods 1858 patients without persistent atrial fibrillation with signs and/or symptoms of ischemia and with non-obstructive CAD (<40% stenosis) who underwent invasive coronary microvascular functional assessment and the ECG closest to the functional assessment were included in this analysis. Patients with coronary flow velocity reserve (CFR) <2 in response to adenosine were labelled as endothelial-independent CMD; % increase in coronary blood flow (%ΔCBF) <50% in response to acetylcholine were labelled as endothelial-dependent CMD. Patients were categorized into 4 groups. G1: Normal (NL) CFR/NL %ΔCBF; G2: Abnormal (ABN) %ΔCBF only; G3: ABN CFR only; G4: ABL CFR & %ΔCBF. The probability of having PAF (%probAF) was calculated by a previously-trained and validated AI algorithm. AF Flag = %probAF >9%; which is a pre-set cut-off found to have the highest accuracy of identifying patients with PAF (Area Under the Curve = 0.87). Results Mean age for patients was 51.2±12.4 and 66.3% were females. 835 (45%) were in G1, 39 (2%) in G2, 911 (49%) in G3, and 73 (4%) in G4. Compared to G1 and G2, G3 and G4 were older, had more diabetes and higher smoking rates (p<0.05 for all). Furthermore, G4 had a significantly higher %probAF compared to other groups (Fig. 1). G4 were also more likely to be flagged by the algorithm as having PAF, even after adjusting for cardiovascular risk factors, with an odds ratio of 1.9 [CI 95% 1.1–3.3; p=0.03]) (Fig. 2). Conclusion Patients with combined CMD have a significantly higher probability of having PAF based on an AI-enabled algorithm. Further research is warranted to know if patients with CMD would benefit from formal AF screening at the time of diagnosis. Funding Acknowledgement Type of funding source: None
A cool modality to restore sinus rhythm
Yasin, Omar , Sugrue, Alan , Zyl, Martin van , Ladejobi, Adetola, Tri, Jason , Rynbrandt, J, Seifert, Gregory J., Sanders, R., Pedersen, Joanne, Yngsdal, Lisa, Ladewig, Dorothy J., Taubel, R, Ritrivi, Charles, Asirvatham, S, Friedman, Paul A. , Rynbrandt, Jeff, Seifert, Greg

European Heart Journal | November 26, 2020 | Volume: 41 | Issue: Supplement_2 | Pages: No page available

10.1093/ehjci/ehaa946.0551 Get It

Abstract Background Slowing electrical conduction by cooling the myocardium can be used for defibrillation. We previously demonstrated the efficacy of a small cold device placed in oblique sinus (OS) in terminating atrial fibrillation (AF). However, the parameters needed to achieve effective atrial defibrillation are unknown. Purpose Assess effect of the size of cooled myocardium on frequency of AF termination in acute canine animal models. Methods Sternotomy was performed under general anesthesia in 10 acute canine experiments. AF was induced using rapid atrial pacing and intra-myocardial epinephrine and acetylcholine injections. Once AF sustained for at least 30s, either a cool (7–9°C) or placebo (body temperature) device was placed in the OS. Four device sizes were tested; ½X½, ¾X¾, and 1X1 inch devices and two ¾X¾ inch devices placed side by side simultaneously. Time to AF termination was recorded. Chi-squared or Fisher's exact test were used to compare the frequency of arrhythmia termination with cooling versus placebo. Results A total of 166 applications were performed (89 cool vs 77 placebo) in 10 animal experiments. Overall, AF terminated in 82% of the cooling applications vs. 67.5% of placebo (P=0.03, Figure 1). For the ½X½ inch device 88% of cold applications restored sinus rhythm vs. 63.6% for placebo (P=0.05). The frequency of sinus restoration for cold ¾X¾, 1X1 and two ¾X¾ side by side devices was 86.7%, 83.3% and 70% respectively. Time to sinus restoration when achieved was within three minutes was also not significantly changed. Conclusion Placing a cool device in the oblique sinus can terminate AF and efficacy is not affected by the size of device. Funding Acknowledgement Type of funding source: Private grant(s) and/or Sponsorship. Main funding source(s): MediCool Technologies
Sound wave balloon-assisted device implantation: a novel approach that merits consideration
Barake, Walid , Madhavan, Malini , Kowlgi, Gurukripa N. , Cha, Yong‐Mei , Asirvatham, Samuel J. , Friedman, Paul A. , Asirvatham, Samuel J , Kowlgi, Narayan G

EP Europace | November 19, 2020 | Volume: 23 | Issue: 5 | Pages: 747-747

10.1093/europace/euaa281 Get It

Artificial Intelligence–Electrocardiography to Predict Incident Atrial Fibrillation
Christopoulos, Georgios , Graff‐Radford, Jonathan , Lopez, Camden , Yao, Xiaoxi , Attia, Zachi I. , Rabinstein, Alejandro A. , Petersen, Ronald C. , Knopman, David S. , Mielke, Michelle M. , Kremers, Walter K. , Vemuri, Prashanthi , Siontis, Konstantinos C. , Friedman, Paul A. , Knopman, David S. , Lopez, Camden L, Mielke, Michelle M , Vemuri, Prashanthi , Lopez, Camden L , Attia, Zachi I , Yao, Xiaoxi , Rabinstein, Alejandro A , Kremers, Walter K , Noseworthy, Peter A.

Circulation: Arrhythmia and Electrophysiology | November 13, 2020 | Volume: 13 | Issue: 12 | Pages: No page available

10.1161/circep.120.009355 Get It

Background: An artificial intelligence (AI) algorithm applied to electrocardiography during sinus rhythm has recently been shown to detect concurrent episodic atrial fibrillation (AF). We sought to characterize the value of AI–enabled electrocardiography (AI-ECG) as a predictor of future AF and assess its performance compared with the CHARGE-AF score (Cohorts for Aging and Research in Genomic Epidemiology–AF) in a population-based sample. Methods: We calculated the probability of AF using AI-ECG, among participants in the population-based Mayo Clinic Study of Aging who had no history of AF at the time of the baseline study visit. Cox proportional hazards models were fit to assess the independent prognostic value and interaction between AI-ECG AF model output and CHARGE-AF score. C statistics were calculated for AI-ECG AF model output, CHARGE-AF score, and combined AI-ECG and CHARGE-AF score. Results: A total of 1936 participants with median age 75.8 (interquartile range, 70.4–81.8) years and median CHARGE-AF score 14.0 (IQR, 13.2–14.7) were included in the analysis. Participants with AI-ECG AF model output of >0.5 at the baseline visit had cumulative incidence of AF 21.5% at 2 years and 52.2% at 10 years. When included in the same model, both AI-ECG AF model output (hazard ratio, 1.76 per SD after logit transformation [95% CI, 1.51–2.04]) and CHARGE-AF score (hazard ratio, 1.90 per SD [95% CI, 1.58–2.28]) independently predicted future AF without significant interaction ( P =0.54). C statistics were 0.69 (95% CI, 0.66–0.72) for AI-ECG AF model output, 0.69 (95% CI, 0.66–0.71) for CHARGE-AF, and 0.72 (95% CI, 0.69–0.75) for combined AI-ECG and CHARGE-AF score. Conclusions: In the present study, both the AI-ECG AF model output and CHARGE-AF score independently predicted incident AF. The AI-ECG may offer a means to assess risk with a single test and without requiring manual or automated clinical data abstraction.
Abstract 17219: Non-Invasive, Blood-Free Point of Care Test to Rapidly Exclude Myocardial Injury: The AI ECG
Sandoval, Yader , Jaffe, Allan S. , Friedman, Paul A. , Attia, Zachi I. , Carter, Rickey E. , Kapa, Suraj , López-Jiménez, Francisco , Noseworthy, Peter A. , Jaffe, Allan S.

Circulation | November 12, 2020 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.17219 Get It

Background: Myocardial injury results in release of cardiac troponin (cTn) into the bloodstream, readily detected by high-sensitivity cTn (hs-cTn) assays. A noninvasive, rapid, home-based test to exclude acute myocardial injury at the time of the test and for the next 7 hours would help manage patients with suspected myocardial infarction. Since myocyte injury is associated with ECG changes, we hypothesized an artificial intelligence ECG (AI-ECG) could identify absence of injury. Objective: To train and test an AI-ECG convolutional neural network (CNN) to identify patients using a single ECG who are suspected of myocardial infarction who are low risk, with hs-cTn levels below the 99 th percentile at test time and for the subsequent 7 hours. Methods: A CNN tuned to identify the absence of a hs-cTnT (5 th Gen cTnT Roche Diagnostics) >15ng/L for men and >10ng/L for women was developed. All ECGs were recorded within one hour of the hs-cTnT assay. We used 73,012 ECGs and hs-cTnT pairs from 47,542 unique patients to train the network, 9031 ECGs from 5,811 patients for internal validation to optimize hyperparameters, and 11,904 ECGs with 21,191 hs-cTnT measurements up to 7 hours after the ECG, from 11,904 different patients as a holdout test set. Results: The mean age was 63.9±17.5 years, and 30,348 of the 59,446 patients (51%) were male. 5,852 patients (49.1%) had no elevation of hs-cTnT and 6,052 (50.9%) had an hs-cTnT above the 99 th percentile at baseline or within 7 hours of the test. Of the 11,904 patients in the test set, using a sensitive threshold, the 12 lead AI ECG identified 1037 patients (8.7%) likely to have a low risk for subsequent hs-cTnT increases > 99 th % (AUC 0.86), and the single lead ECG identified 685 patients. Of the 1037 low risk pts, 59 had an hs-cTnT > 99 th percentile within 7 hours. The mean maximum hs-cTnT among the 59 low-risk patients was 53 ng/L ± 92 vs 184 ng/L ± 1474 in the others. None of these low risk patients died within 14 days of the test. Conclusion: Use of the AI ECG to identify patients without cardiac injury at the time of the test and for 7 subsequent hours is feasible. This may permit rapid, point of care, home-based, bloodless, painless testing to exclude cardiac injury, facilitating care and management of patients with suspected ischemia.
Abstract 17152: Artificial Intelligence ECG for the Detection of Cardiac Injury as Confirmed by High Sensitivity Cardiac Troponin T-Concentrations
Sandoval, Yader , Jaffe, Allan S. , Friedman, Paul A. , Attia, Zachi I. , Carter, Rickey E. , Kapa, Suraj , López-Jiménez, Francisco , Noseworthy, Peter A. , Jaffe, Allan S.

Circulation | November 12, 2020 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.17152 Get It

Background: High-sensitivity cardiac troponin (hs-cTn) assays quantify cTn in patients at very low concentrations. Myocyte injury due to ischemia or other pathologies cause blood levels to increase, which is prognostic. A noninvasive, rapid, broadly available, home-based test to detect hs-cTn increases would facilitate risk-stratification. Since myocyte injury is associated with ECG changes, we hypothesized an artificial intelligence ECG (AI-ECG) could non-invasively predict current or impending hs-cTnT elevations. Objective: To develop an AI-ECG convolutional neural network (CNN) to detect an abnormal hs-cTnT (5 th Gen cTnT, Roche Diagnostics) concentration using a 12-lead ECG, and a single lead ECG (lead I), which would enable smartphone, home-based detection. Methods: We developed single lead and 12-lead ECG CNNs to detect a) hs-cTnT concentrations that were at or above the 6ng/L limit that can be reported b) above the 99 th percentile upper limits of >15ng/L for men and >10ng/L for women. All ECGs were recorded within one hour of the hs-cTnT measurements. We used 73,012 ECG and hs-cTnT pairs from 47,542 unique patients to train the network, 9031 ECGs from 5,811 patients for internal validation to optimize hyperparameters, and 18,276 ECG and hs-cTnT pairs from 11,904 different patients as a holdout test set to determine the area under the receiver-operator curve (AUC). Results: The mean age was 63.9±17.5 years, and 30,348 of the 59,446 patients (51%) were male. Of the 91,288 hs-cTnT pairs 73,271 (80.2%) were above 6ng/L and 50,799 (55.6%) are above the 99 th percentile. In the test set, the AUC for the detection of a hs-cTnT level higher than 6ng/L was 0.88 using the 12 lead ECG and 0.834 with the single lead. For the detection of hs-cTnT level above of 99 th percentile, the 12 lead ECG AUC was 0.853 and the single lead was 0.806. Conclusion: The AI-ECG permits detection of levels of hs-cTnT consistent with myocardial injury. This may allow a home-based, non-invasive test that would be massively scalable and could further enhance rapid-risk stratification and patient triage with potentially significant cost reductions and enable novel triage strategies at sites without hs-cTn assays.
Use of Artificial Intelligence Electrocardiography to Predict Atrial Fibrillation (AF) in Patients with Chronic Lymphocytic Leukemia (CLL)
Christopoulos, Georgios , Call, Timothy G. , Leis, José F., Koehler, Amber B. , Kapoor, Prashant , Friedman, Paul A. , Herrmann, Joerg , Attia, Zachi I. , Noseworthy, Peter A. , Ding, Wei , Muchtar, Eli , Kenderian, Saad S. , Wang, Yucai , Kay, Neil E. , Parikh, Sameer A.

Blood | November 4, 2020 | Volume: 136 | Issue: Supplement 1 | Pages: 50-51

10.1182/blood-2020-142645 Get It

Background: Clinical factors including previous history of AF, heart failure, hypertension, valvular heart disease, increased age and male gender increase the risk of AF in CLL patients (Shanafelt, Leukemia and Lymphoma 2017). Treatment with Bruton tyrosine kinase inhibitors (BTKi) such as ibrutinib has also been associated with an increased risk of AF in CLL. We evaluated the role of artificial intelligence electrocardiography (AI-ECG) in predicting ibrutinib-induced AF (and, for reference, AF unrelated to ibrutinib) in patients with CLL. Methods: We identified two cohorts of CLL patients using the Mayo Clinic CLL Database. Cohort 1 included patients evaluated within 12 months of CLL diagnosis who did not ever receive ibrutinib. Cohort 2 included patients who were treated with ibrutinib. The electrocardiographic signature of AF in sinus rhythm was detected by an AI-ECG algorithm previously developed using a convolutional neural network (Attia, Lancet 2019). The baseline AI-ECG AF score (positive defined as >0.10 on a scale of 0-1 which offers best balance between sensitivity and specificity per Attia et al.) was computed based on ECGs obtained within 10 years prior to CLL diagnosis (Cohort 1) or 10 years prior to initiation of ibrutinib therapy (Cohort 2). Patients with AF at baseline, missing data, or with ECGs previously used to train the AI algorithm were excluded. Reverse Kaplan Meier diagrams were plotted for both cohorts grouped by AI-ECG positivity. Cox proportional hazards were fitted to assess the predictive ability of AI-ECG in both cohorts. Results: After screening 2,739 patients and applying exclusion criteria (126 patients had baseline AF) a total of 1,149 patients with median 4 (interquartile range [IQR] 2-9) baseline ECGs were included in the analysis (Figure 1A). Cohort 1 included 951 patients with a median follow up of 3.0 (IQR 0.6-7.0) years and positive baseline AI-ECG in 546 (57%) patients. Cohort 2 included 198 patients with a median follow up of 1.6 (IQR 0.7-3.2) years and positive baseline AI-ECG in 91 (46%) patients. In Cohort 1, the median age was 67 years (IQR 58-72), 681 (72%) of patients were men, 68% had low/intermediate risk CLL-International Prognostic Index (IPI), and 32% had high/very high-risk CLL-IPI. In Cohort 2, the median age was 69 years (IQR 62-75), 139 (70%) of patients were men, 13% had low/intermediate risk CLL-IPI, and 87% had high/very high-risk CLL-IPI. AF occurred during follow up in 164 patients (17%) in Cohort 1 and 46 patients (23%) in Cohort 2. In both Cohorts 1 and 2, a positive baseline AI-ECG significantly increased the incidence of AF during follow up (log rank <0.001) (Figure 1B and C). Hazard ratios (for positive vs. negative AI-ECG) were 33.9 (95% confidence interval [CI] 15.0-76.6) for Cohort 1 and 14.8 (95% CI 5.3-41.3) for Cohort 2. Conclusion: The addition of AI to a standard 12-lead ECG obtained during normal sinus rhythm - an inexpensive and ubiquitous test - predicts the occurrence of future AF in patients with CLL. This holds true irrespective of BTKi -based therapy and has important implications for the management of CLL patients. Disclosures Ding: Merck: Membership on an entity's Board of Directors or advisory committees, Research Funding; DTRM: Research Funding; Astra Zeneca: Research Funding; Abbvie: Research Funding; Octapharma: Membership on an entity's Board of Directors or advisory committees; MEI Pharma: Membership on an entity's Board of Directors or advisory committees; alexion: Membership on an entity's Board of Directors or advisory committees; Beigene: Membership on an entity's Board of Directors or advisory committees. Kenderian:BMS: Research Funding; Gilead: Research Funding; Novartis: Patents & Royalties, Research Funding; Mettaforge: Patents & Royalties; Juno: Research Funding; MorphoSys: Research Funding; Lentigen: Research Funding; Sunesis: Research Funding; Tolero: Research Funding; Kite: Research Funding; Humanigen: Consultancy, Patents & Royalties, Research Funding; Torque: Consultancy. Wang:Novartis: Research Funding; Innocare: Research Funding; Incyte: Research Funding. Kay:Juno Theraputics: Membership on an entity's Board of Directors or advisory committees; Oncotracker: Membership on an entity's Board of Directors or advisory committees; Dava Oncology: Membership on an entity's Board of Directors or advisory committees; Rigel: Membership on an entity's Board of Directors or advisory committees; Morpho-sys: Membership on an entity's Board of Directors or advisory committees; Cytomx: Membership on an entity's Board of Directors or advisory committees; Agios Pharma: Membership on an entity's Board of Directors or advisory committees; Astra Zeneca: Membership on an entity's Board of Directors or advisory committees; Sunesis: Research Funding; Abbvie: Research Funding; MEI Pharma: Research Funding; Pharmacyclics: Membership on an entity's Board of Directors or advisory committees, Research Funding; Acerta Pharma: Research Funding; Bristol Meyer Squib: Membership on an entity's Board of Directors or advisory committees, Research Funding; Tolero Pharmaceuticals: Membership on an entity's Board of Directors or advisory committees, Research Funding. Kapoor:Cellectar: Consultancy; Janssen: Research Funding; Sanofi: Consultancy, Research Funding; Amgen: Research Funding; Takeda: Honoraria, Research Funding; Celgene: Honoraria; GlaxoSmithKline: Research Funding. Parikh:MorphoSys: Research Funding; Janssen: Honoraria, Research Funding; AstraZeneca: Honoraria, Research Funding; Merck: Research Funding; AbbVie: Honoraria, Research Funding; Ascentage Pharma: Research Funding; Genentech: Honoraria; Verastem Oncology: Honoraria; GlaxoSmithKline: Honoraria; TG Therapeutics: Research Funding; Pharmacyclics: Honoraria, Research Funding.
Utilization and procedural adverse outcomes associated with Watchman device implantation
Khalil, Fouad , Arora, Shilpkumar , Killu, Ammar M. , Egbe, Alexander C. , Kapa, Suraj , Mulpuru, Siva K. , Mohamad, Alkhouli, Friedman, Paul A. , Holmes, David R. , Deshmukh, Abhishek , Mulpuru, Siva, Khalil, Fouad , Kapa, Suraj , Tripathi, Byomesh , DeSimone, Christopher V. , Noseworthy, Peter A. , Gersh, Bernard J.

EP Europace | August 9, 2020 | Volume: 23 | Issue: 2 | Pages: 247-253

10.1093/europace/euaa219 Get It

AbstractAims The Food and Drug Administration (FDA) approval of the Watchman device [percutaneous left atrial appendage occlusion (LAAO)] has resulted in the widespread use of this procedure in many centres across the USA. We sought to estimate the nationwide utilization and frequency of adverse outcomes associated with Watchman device implantation. The objective of this study was to evaluate the Watchman device implantation peri-procedural complications and comparison of the results with the previous studies.Methods and results The National Inpatient Sample (NIS) was queried for all hospitalizations with a primary diagnosis of atrial fibrillation or atrial flutter during the year 2016 with percutaneous LAAO during the same admission (ICD-10 code—02L73DK). The frequency of peri-procedural complications, including mortality, procedure-related stroke, major bleeding requiring blood transfusion, and pericardial effusion, was assessed. We compared the complication rates with the published randomized controlled trials and the European Watchman registry. An estimated 5175 LAAO procedures were performed in 2016. The majority of procedures was performed in males (59.1%), age ≥75 years (58.7%), and White (83.1%). The overall complication rate was 1.9%. The in-hospital mortality was 0.29%. Pericardial effusion requiring pericardiocentesis was the most frequent complication (0.68%). Bleeding requiring transfusion was noted in 0.1% of device implants. The rates of post-procedure stroke and systemic embolism were 0% and 0.29%, respectively.Conclusion Percutaneous LAAO with the Watchman device in the USA is associated with low in-hospital complications and a similar safety profile to a recently published EWOLUTION cohort. The complication rates were lower than those reported in the major randomized clinical trials (RCTs). We report the frequency of peri-procedural complications of the LAAO using the Watchman device from the NIS database. We also compare the frequency of peri-procedural complications with the previously published RCTs and EWOLUTION cohort. Our findings are in concordance with findings from EWOLUTION cohort and compare favourably with RCTs.
Prospective evaluation of the utility of magnetic resonance imaging in patients with non‐MRI‐conditional pacemakers and defibrillators
Padmanabhan, Deepak , Kella, Danesh , Isath, Ameesh , Tandon, Nidhi , Mulpuru, Siva K. , Deshmukh, Abhishek , Mehta, Ramila A. , Dalzell, Connie, Olson, Nora E., Felmlee, Joel P. , Jondal, Mary Lou, Asirvatham, Samuel J. , Watson, Robert E. , Cha, Yong‐Mei , Friedman, Paul A. , Mulpuru, Siva K , Kapa, Suraj , Mehta, Ramila, Olson, Nora, Felmlee, Joel, Jondal, Mary L, Asirvatham, Samuel J , Cha, Yong-Mei , Friedman, Paul A , Kella, Danesh K , Kapa, Suraj

Journal of Cardiovascular Electrophysiology | August 5, 2020 | Volume: 31 | Issue: 11 | Pages: 2931-2939

10.1111/jce.14705 Get It

AbstractBackgroundMagnetic resonance imaging (MRI) in patients with legacy cardiovascular implantable electronic devices (CIEDs) in situ is likely underutilized. We hypothesized the clinical benefit of MRI would outweigh the risks in legacy CIED patients.MethodsThis is a single‐center retrospective study that evaluated and classified the utility of MRI using a prospectively maintained database. The outcomes were classified as aiding in diagnosis, treatment, or both for the patients attributable to the MRI. We then assessed the incidence of adverse effects (AE) when the MRI was performed.ResultsIn 668, MRIs performed on 479 patients, only 13 (1.9%) MRIs did not aid in the diagnosis or treatment of the patient. Power‐on reset events without clinical sequelae in three scans (0.45%) were the only AE. The probability of an adverse event happening without any benefit from the MRI scan was 1.1 × 10−4. A maximum benefit in diagnosis using MRI was obtained in ruling out space‐occupying lesions (121/185 scans, 65.4%). Scans performed in patients for elucidating answers to queries in treatment were most frequently done for disease staging at long term follow‐up (167/470 scans, 35.5%). Conservative treatment (184/470 scans, 39%) followed by medication changes (153/470 scans, 28.7%) were the most common treatment decisions made.ConclusionsThe utility of MRI in patients with non‐MRI‐conditional CIEDs far outweighs the risk of adverse events when imaging is done in the context of a multidisciplinary program that oversees patient safety.
Artificial Intelligence-Enabled ECG Algorithm to Identify Patients With Left Ventricular Systolic Dysfunction Presenting to the Emergency Department With Dyspnea
Adedinsewo, Demilade , Carter, Rickey E. , Attia, Zachi I. , Kashou, Anthony H. , Dugan, Jennifer , Albus, Michael, Bellolio, Fernanda , Friedman, Paul A. , Johnson, Patrick, Dugan, Jennifer L, Sheele, Johnathan M. , Carter, Rickey E , Adedinsewo, Demilade A , Bellolio, M Fernanda , Attia, Zachi I , Johnson, Patrick W. , López-Jiménez, Francisco , Noseworthy, Peter A.

Circulation: Arrhythmia and Electrophysiology | August 4, 2020 | Volume: 13 | Issue: 8 | Pages: No page available

10.1161/circep.120.008437 Get It

Background: Identification of systolic heart failure among patients presenting to the emergency department (ED) with acute dyspnea is challenging. The reasons for dyspnea are often multifactorial. A focused physical evaluation and diagnostic testing can lack sensitivity and specificity. The objective of this study was to assess the accuracy of an artificial intelligence-enabled ECG to identify patients presenting with dyspnea who have left ventricular systolic dysfunction (LVSD). Methods: We retrospectively applied a validated artificial intelligence-enabled ECG algorithm for the identification of LVSD (defined as LV ejection fraction ≤35%) to a cohort of patients aged ≥18 years who were evaluated in the ED at a Mayo Clinic site with dyspnea. Patients were included if they had at least one standard 12-lead ECG acquired on the date of the ED visit and an echocardiogram performed within 30 days of presentation. Patients with prior LVSD were excluded. We assessed the model performance using area under the receiver operating characteristic curve, accuracy, sensitivity, and specificity. Results: A total of 1606 patients were included. Median time from ECG to echocardiogram was 1 day (Q1: 1, Q3: 2). The artificial intelligence-enabled ECG algorithm identified LVSD with an area under the receiver operating characteristic curve of 0.89 (95% CI, 0.86–0.91) and accuracy of 85.9%. Sensitivity, specificity, negative predictive value, and positive predictive value were 74%, 87%, 97%, and 40%, respectively. To identify an ejection fraction <50%, the area under the receiver operating characteristic curve, accuracy, sensitivity, and specificity were 0.85 (95% CI, 0.83–0.88), 86%, 63%, and 91%, respectively. NT-proBNP (N-terminal pro-B-type natriuretic peptide) alone at a cutoff of >800 identified LVSD with an area under the receiver operating characteristic curve of 0.80 (95% CI, 0.76–0.84). Conclusions: The ECG is an inexpensive, ubiquitous, painless test which can be quickly obtained in the ED. It effectively identifies LVSD in selected patients presenting to the ED with dyspnea when analyzed with artificial intelligence and outperforms NT-proBNP. Graphic Abstract: A graphic abstract is available for this article.