Citations

Mayo Clinic

Showing 10 of 108523 citations.

Calcium-sensing receptor antagonists abrogate airway hyperresponsiveness and inflammation in allergic asthma
Yarova, Polina , Stewart, Alecia, Sathish, Venkatachalem , Britt, Rodney D. , Lowe, Alexander P. P. , Freeman, Michelle, Aravamudan, Bharathi, Kita, Hirohito , Brennan, Sarah C. , Schepelmann, Martin , Yung, Sun, Cholisoh, Zakky , Kidd, Emma J. , Rietdorf, Katja , Chang, Wenhan , Khayat, Mohd Ezuan , Ward, Donald T. , Corrigan, Christopher J. , Ward, Jeremy , Prakash, Y. S. , Riccardi, Daniela , Stewart, Alecia L, Thompson, Michael A. , Davies, Thomas , Ford, William R. , Broadley, Kenneth J. , Kemp, Paul J. , Pabelick, Christina M. , Prakash, Y S , Kita, H , Sathish, Venkatachalem

Science Translational Medicine | April 22, 2015 | Volume: 7 | Issue: 284 | Pages: No page available

10.1126/scitranslmed.aaa0282 | PMID 25904744 Get It

Calcilytics reduce airway hyperresponsiveness and inflammation and may represent effective asthma therapeutics.
Dual-Acquisition Extracranial Computed Tomographic Angiography-Enhanced Neck Computed Tomography before Transoral Laser Microsurgery in Head and Neck Cancer Patients
Weindling, Steven M. , Salassa, John R., Casler, J.D., Chellini, David

The Neuroradiology Journal | April 22, 2015 | Volume: 24 | Issue: 3 | Pages: 379-391

10.1177/197140091102400306 | PMID 24059660 Get It

Transoral laser microsurgery (TLM) is an alternative surgical technique for piecemeal endoscopic resection of mucosal-based aerodigestive tract tumors. Though uncommon, potentially catastrophic postoperative bleeding may occur with this technique secondary to vascular injury along invasive tumor inner margins. We describe our preliminary results using a preoperative dual-acquisition extracranial computed tomographic angiography (CTA)-enhanced neck computed tomographic (CT) imaging and postprocessing protocol developed to improve visualization of mucosal-based head and neck tumors and adjacent arterial branches with the objective of facilitating TLM surgery and reducing secondary bleeding complications. Twenty patients with known head and neck cancers anticipated for TLM resection were selected for a dual-acquisition CTA-CT scanning and postprocessing protocol. The mucosal-based pharyngeal tumors and peritumoral vessel enhancement were compared on matched CTA and enhanced neck CT axial images. Operative reports and clinical notes were retrospectively reviewed to identify patients in whom the TLM surgical approach was altered or changed to conventional open surgery as a result of presurgical CTA-CT findings. Enhancement of peritumoral vasculature was almost uniformly superior (19 of 20 patients) on extracranial CTA compared with enhanced neck CT images. In six candidates for TLM surgery (30%), CTA findings resulted in a change in surgical approach to improve intraoperative peritumoral vascular control. In this small pilot series, primary tumor-peritumoral vessel relationships delineated by the addition of extracranial CTA to preoperative enhanced neck CT frequently impacted the surgical approach and facilitated TLM planning.
Do the Advantages of the FiberNet® Embolic Protection Device Translate into Technical Success and Comparable Event Rates in Carotid Artery Stenting?
D'Souza, Seema, Slovut, David P., Bower, Thomas C., Bacharach, J. Michael

The Neuroradiology Journal | April 22, 2015 | Volume: 22 | Issue: 1 | Pages: 80-85

10.1177/197140090902200112 | PMID 24206956 Get It

FiberNet® is a second generation non-conventional embolization protection device (EPD) that purports to offer several advantages: ability to capture debris as small as 40 μm, more flexibility with placement and positioning in curved segments requiring a small landing zone, ability to conform to asymmetric vessels, and improved deliverability. The design features a low profile with large surface area to capture debris. Legitimate concerns include inducement of obstruction or low flow with debris capture and requirements in the IFU to aspirate during re-capture and device removal. Our goal was to compare the results of carotid artery stenting (CAS) using FiberNet® against a multi-center experience of CAS using other filter devices to identify any differences in technical success or event rates. FiberNet® (n=25) results were compared to all CAS cases performed at the Mayo Clinic in Rochester, MN, St Mary's/Duluth Clinic in MN, and North Central Heart Institute in Sioux Falls, SD (n=250) from March 2001 to December 2008. Chi-square or means were used to compare variables, as appropriate. Bivariate logistic regression was used to identify possible correlates of adverse outcome. Statistical significance was set at < 0.05. FiberNet® patients were more likely to be older (78.1+5.4 vs 73.6+9.4, p=0.019), female (48% vs 29%, p=0.047), and have peripheral vascular disease (84.0% vs 37.2%, p=0.025), and less likely to have diabetes (8.0% vs 29.8%, p=0.012) than patients in the comparison group. FiberNet® patients had more lesion calcification (40.0% vs 18.9%, p=0.014) and increased number of type 2 and 3 arches (44.2% vs 73.9%, p=0.006). Procedural success rate was 100% in both groups. None of the FiberNet® patients showed evidence of stagnant flow. The thirty-day outcome for TIA, CVA, or death was 4% in FiberNet® versus 4.8% in the comparison group (p NS). None of the independent variables – age gender, serum creatinine, arch complexity, lesion length, lesion calcium, lesion thrombus, PVD, diabetes, contralateral carotid occlusion, or ipsilateral carotid endarterectomy – predicted adverse events. Although FiberNet® patients had more lesion calcium and more challenging arch anatomy, procedural success and adverse events were comparable between groups. The advantages of FiberNet® can be applied to CAS with good technical results and may be a promising EPD for certain high-risk situations.
Pathogenesis, Natural History, and Treatment of Unruptured Intracranial Aneurysms
Wiebers, David O. , Piepgras, David G., Meyer, Fredric B. , Kallmes, David F. , Meissner, Irene, Atkinson, John L. D., Link, Michael J., Brown, Robert D., Link, Michael J.

The Neuroradiology Journal | April 22, 2015 | Volume: 19 | Issue: 4 | Pages: 504-515

10.1177/197140090601900409 | PMID 24351251 Get It

Unruptured intracranial aneurysms (UIAs) are a major public health issue. These lesions have become increasingly recognized in recent years with the advent of advanced cerebral imaging techniques. Epidemiological evidence from multiple sources suggests that most intracranial aneurysms do not rupture. Therefore, it is desirable to identify which UIAs are at greatest risk of rupture when considering which to repair. It is important to compare size-, site-, and group-specific natural history rates with size-, site-, and age-specific morbidity and mortality associated with UIA repair because increased natural history risk often is associated with increased risk of aneurysm repair. Patient age is crucial in decision making because of its major effect on operative morbidity and mortality; however, it does not substantially affect natural history. The effect of age is most notable in patients about 50 years of age and older for open surgery and about 70 years of age and older for endovascular procedures. In general, rupture risk is lowest for patients in asymptomatic group 1 (no history of subarachnoid hemorrhage) with UIAs less than 7 mm in diameter in the anterior circulation. Surgical morbidity and mortality are most favorable for asymptomatic patients younger than 50 years who have UIAs less than 24 mm in diameter in the anterior circulation and no history of ischemic cerebrovascular disease. Endovascular morbidity and mortality may be less age dependent, and this could favor endovascular procedures, particularly in patients aged 50 to 70 years. An important issue is determining immediate vs long-term risk regarding treatment effectiveness and durability. This issue emphasizes the importance of long-term follow-up in patients after surgical and endovascular procedures.
High Resolution Contrast-Enhanced MR Angiography in the Evaluation of Rabbit Carotid Artery
Wu, Renhua , Kallmes, David F.

Rivista di Neuroradiologia | April 22, 2015 | Volume: 18 | Issue: 5-6 | Pages: 529-536

10.1177/197140090501800502 Get It

This study compared a high resolution contrast-enhanced MR angiography (MRA) sequence to conventional contrast-enhanced MRA sequence for imaging of rabbit carotid artery. Fifteen rabbits underwent an evaluation using both high resolution contrast-enhanced MRA sequence and conventional contrast-enhanced MRA sequence. Siemens 1.5 Tesla Magnetom Vision system was utilized. The parameters of high resolution sequence were: TR/TE= 6.2/2.0 msec, flip angle 25°, matrix 130×512, pixel size 0.96×0.49 mm, partition thickness 1.58 mm, acquisition time 24 sec. The parameters of conventional sequence were: TR/TE=3.8/1.4 msec, flip angle 35°, matrix 110×256, pixel size 1.48×1.02 mm, partition thickness 2mm, acquisition time 10 sec. Maximum intensity projection (MIP) images were created. Both original single slices and MIP images were used for image quality evaluation. Contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), distinctness of artery edge, and venous contamination were analyzed for both techniques. Higher average CNR and SNR were obtained with high resolution contrast-enhanced MRA, compared to average CNR and SNR with conventional contrast-enhanced MRA. The differences were statistically significant (P<0.01). The artery edge with high resolution method was more distinct than conventional method. Jugular venous contamination was found in five of 15 cases with high resolution contrast-enhanced MRA and in four of 15 cases with conventional contrast-enhanced MRA. High resolution contrast-enhanced MRA has significant potential for high quality noninvasive vascular imaging. The image quality with high resolution contrast-enhanced MRA sequence is better than conventional contrast-enhanced MRA sequence.
Endovascular Coil Occlusion of Ruptured Saccular Cerebral Aneurysms Using Guglielmi Detachable Coils
Friedman, Jonathan A., Nichols, D A, Meyer, Fredric B. , Pichelmann, Mark A., McIver, Jon I., Toussaint, L. Gerard , Axley, P L, Brown, Robert D.

Rivista di Neuroradiologia | April 22, 2015 | Volume: 16 | Issue: 6 | Pages: 1213-1222

10.1177/197140090301600649 Get It

Aortic Arch and Carotid Artery Single-Shot Gadolinium-Enhanced 3D MR Angiography with an Elliptical Centric Acquisition Order
Fain, Sean B. , Wilman, Alan H. , Riederer, Stephen J. , Huston, John

Rivista di Neuroradiologia | April 22, 2015 | Volume: 11 | Issue: 2_suppl | Pages: 179-183

10.1177/19714009980110s252 Get It

We sought to obtain high resolution 3D contrast-enhanced MR angiograms of the carotid arteries, vertebral arteries and aortic arch with venous signal suppression utilizing novel timing techniques. A secondary purpose was to compare contrast-enhanced MR angiograms with 2D time-of-flight MR angiograms of the carotid arteries.
Disseminated Ureaplasma infection as a cause of fatal hyperammonemia in humans
Bharat, Ankit , Cunningham, Scott A. , Kreisel, Daniel , DeWet, Charl J., Waites, Ken B. , Crabb, Donna M., Xiao, Li , Bhorade, Sangeeta , Ambalavanan, Namasivayam , Dilling, Daniel F. , Lowery, Erin M. , Astor, T., Krupnick, Alexander S. , DeCamp, Malcolm M., Patel, Robin , Budinger, G. R. Scott , Gelman, Andrew E , Hachem, Ramsey R. , Ison, Michael G. , Patel, Robin , Cunningham, Scott A

Science Translational Medicine | April 22, 2015 | Volume: 7 | Issue: 284 | Pages: No page available

10.1126/scitranslmed.aaa8419 | PMID 25904745 Get It

Disseminated infection with Ureaplasma species causes fatal hyperammonemia syndrome in lung transplant recipients, likely by disrupting ammonia metabolism.
A Long Way from Morphine in Rural Cameroon
Schoonover, Kimberly

Journal of Palliative Medicine | April 22, 2015 | Volume: 18 | Issue: 6 | Pages: 554-554

10.1089/jpm.2014.0442 | PMID 25901997 Get It

A Technique for Quantifying Wrist Motion Using Four-Dimensional Computed Tomography: Approach and Validation
Zhao, Kristin D. , Breighner, Ryan , Holmes, David R. , An, Kai‐Nan, Leng, Shuai , McCollough, Cynthia H. , Trentadue, Taylor P

Journal of Biomechanical Engineering | April 22, 2015 | Volume: 137 | Issue: 7 | Pages: No page available

10.1115/1.4030405 | PMID 25901447 Get It

Accurate quantification of subtle wrist motion changes resulting from ligament injuries is crucial for diagnosis and prescription of the most effective interventions for preventing progression to osteoarthritis. Current imaging techniques are unable to detect injuries reliably and are static in nature, thereby capturing bone position information rather than motion which is indicative of ligament injury. A recently developed technique, 4D (three dimensions + time) computed tomography (CT) enables three-dimensional volume sequences to be obtained during wrist motion. The next step in successful clinical implementation of the tool is quantification and validation of imaging biomarkers obtained from the four-dimensional computed tomography (4DCT) image sequences. Measures of bone motion and joint proximities are obtained by: segmenting bone volumes in each frame of the dynamic sequence, registering their positions relative to a known static posture, and generating surface polygonal meshes from which minimum distance (proximity) measures can be quantified. Method accuracy was assessed during in vitro simulated wrist movement by comparing a fiducial bead-based determination of bone orientation to a bone-based approach. The reported errors for the 4DCT technique were: 0.00–0.68 deg in rotation; 0.02–0.30 mm in translation. Results are on the order of the reported accuracy of other image-based kinematic techniques.