Back to Authors

Breighner, Ryan

https://orcid.org/0000-0002-2190-3597

Mayo Clinic

Hospital for Special Surgery

Citations 5

Morphology of the scaphotrapeziotrapezoid joint: A multi‐domain statistical shape modeling approach
Trentadue, Taylor P. , Thoreson, Andrew R. , Lopez, Cesar , Holmes, David R. , Rizzo, Marco , Zhao, Kristin D. , Thoreson, Andrew, Trentadue, Taylor P , Trentadue, Taylor P , Breighner, Ryan , Leng, Shuai , Holmes, David R., Kakar, Sanjeev

Journal of Orthopaedic Research | July 3, 2024 | Volume: 42 | Issue: 11 | Pages: 2562-2574

10.1002/jor.25918 Get It

Abstract The scaphotrapeziotrapezoid (STT) joint is involved in load transmission between the wrist and thumb. A quantitative description of baseline STT joint morphometrics is needed to capture the variation of normal anatomy as well as to guide staging of osteoarthritis. Statistical shape modeling (SSM) techniques quantify variations in three‐dimensional shapes and relative positions. The objectives of this study are to describe the morphology of the STT joint using a multi‐domain SSM. We asked: (1) What are the dominant modes of variation that impact bone and articulation morphology at the STT joint, and (2) what are the morphometrics of SSM‐generated STT joints? Thirty adult participants were recruited to a computed tomography study of normal wrist imaging and biomechanics. Segmentations of the carpus were converted to three‐dimensional triangular surface meshes. A multi‐domain, particle‐based entropy system SSM was used to quantify variation in carpal bone shape and position as well as articulation morphology. Articular surface areas and interosseous proximity distributions were calculated between mesh vertex pairs on adjacent bones within distance (2.0 mm) and surface‐normal angular (35°) thresholds. In the SSM, the first five modes of variation captured 76.2% of shape variation and contributed to factors such as bone scale, articular geometries, and carpal tilt. Median interosseous proximities—a proxy for joint space—were 1.39 mm (scaphotrapezium), 1.42 mm (scaphotrapezoid), and 0.61 mm (trapeziotrapezoid). This study quantifies morphological and articular variations at the STT joint, presenting a range of normative anatomy. The range of estimated interosseous proximities may guide interpretation of imaging‐derived STT joint space.
Evaluation of Scapholunate Injury and Repair with Dynamic (4D) CT: A Preliminary Report of Two Cases
Zhao, Kristin D. , Lopez, Cesar , Fautsch, Kalli J., Holmes, David R. , Moran, Steven L. , Thoreson, Andrew R. , Trentadue, Taylor P. , Trentadue, Taylor P , Fautsch, Kalli, Holmes Iii, David R, Trentadue, Taylor P , Breighner, Ryan , Leng, Shuai , III, David R. Holmes, Kakar, Sanjeev

Journal of Wrist Surgery | February 9, 2023 | Volume: 12 | Issue: 03 | Pages: 248-260

10.1055/s-0042-1758159 Get It

Abstract Background In predynamic or dynamic scapholunate (SL) instability, standard diagnostic imaging may not identify SL interosseous ligament (SLIL) injury, leading to delayed detection and intervention. This study describes the use of four-dimensional computed tomography (4DCT) in identifying early SLIL injury and following injured wrists to 1-year postoperatively. Description of Technique 4DCT acquires a series of three-dimensional volume data with high temporal resolution (66 ms). 4DCT-derived arthrokinematic data can be used as biomarkers of ligament integrity. Patients and Methods This study presents the use of 4DCT in a two-participant case series to assess changes in arthrokinematics following unilateral SLIL injury preoperatively and 1-year postoperatively. Patients were treated with volar ligament repair with volar capsulodesis and arthroscopic dorsal capsulodesis. Arthrokinematics were compared between uninjured, preoperative injured, and postoperative injured (repaired) wrists. Results 4DCT detected changes in interosseous distances during flexion-extension and radioulnar deviation. Generally, radioscaphoid joint distances were greatest in the uninjured wrist during flexion-extension and radioulnar deviation, and SL interval distances were smallest in the uninjured wrist during flexion-extension and radioulnar deviation. Conclusion 4DCT provides insight into carpal arthrokinematics during motion. Distances between the radioscaphoid joint and SL interval can be displayed as proximity maps or as simplified descriptive statistics to facilitate comparisons between wrists and time points. These data offer insight into areas of concern for decreased interosseous distance and increased intercarpal diastasis. This method may allow surgeons to assess whether (1) injury can be visualized during motion, (2) surgery repaired the injury, and (3) surgery restored normal carpal motion. Level of Evidence Level IV, Case series.
Case Report: Optimizing Daily Function for People with Below-elbow Limb Deficiency with the SoftHand Pro
Theuer, Amanda, Bicchi, Antonio , Andrews, Karen L., Godfrey, Sasha Blue , Zhao, Kristin D. , Breighner, Ryan , Catalano, Manuel G. , Santello, Marco

The Open Journal of Occupational Therapy | October 16, 2020 | Volume: 8 | Issue: 4 | Pages: 1-7

10.15453/2168-6408.1602 Get It

Background: Innovation in prosthetic devices for adults with upper limb loss is necessary to meet the demand for effective devices to optimize participation in daily activity. We evaluate the SoftHand Pro (SHP) as a terminal device to determine the application of this biologically-inspired prosthetic hand for use for a person with transradial limb deficiency. Method: This case study describes and measures the first use of the SHP by an individual with transradial limb deficiency in their home environment. This paper reports the features and functionality of the SHP prototype and provides recommendations for changes to further optimize function. Results: The participant found the simple mechanics, durability, and ease of use of the SHP to be beneficial. She praised the SHP’s positive impact on quality of life and suggested areas for optimization. Objective assessments of dexterity and function showed improvements. Conclusion: Using a biologically-inspired myoelectric hand provides an opportunity for intuitively controlled grasp of common large and small objects. The simplicity of use and the lightweight, durable design of the SHP has the potential to provide a positive impact on quality of life, and this case study has provided valuable feedback to further improve the hand and enable larger at-home trials.
The Role of Dynamic (4D) CT in the Detection of Scapholunate Ligament Injury
Breighner, Ryan , Moran, Steven L. , Berger, Richard A. , Zhao, Kristin D. , Breighner, Ryan E., Kakar, Sanjeev , Leng, Shuai , McCollough, Cynthia H. , Trentadue, Taylor P

Journal of Wrist Surgery | January 18, 2016 | Volume: 05 | Issue: 04 | Pages: 306-310

10.1055/s-0035-1570463 Get It

A Technique for Quantifying Wrist Motion Using Four-Dimensional Computed Tomography: Approach and Validation
Zhao, Kristin D. , Breighner, Ryan , Holmes, David R. , An, Kai‐Nan, Leng, Shuai , McCollough, Cynthia H. , Trentadue, Taylor P

Journal of Biomechanical Engineering | April 22, 2015 | Volume: 137 | Issue: 7 | Pages: No page available

10.1115/1.4030405 Get It

Accurate quantification of subtle wrist motion changes resulting from ligament injuries is crucial for diagnosis and prescription of the most effective interventions for preventing progression to osteoarthritis. Current imaging techniques are unable to detect injuries reliably and are static in nature, thereby capturing bone position information rather than motion which is indicative of ligament injury. A recently developed technique, 4D (three dimensions + time) computed tomography (CT) enables three-dimensional volume sequences to be obtained during wrist motion. The next step in successful clinical implementation of the tool is quantification and validation of imaging biomarkers obtained from the four-dimensional computed tomography (4DCT) image sequences. Measures of bone motion and joint proximities are obtained by: segmenting bone volumes in each frame of the dynamic sequence, registering their positions relative to a known static posture, and generating surface polygonal meshes from which minimum distance (proximity) measures can be quantified. Method accuracy was assessed during in vitro simulated wrist movement by comparing a fiducial bead-based determination of bone orientation to a bone-based approach. The reported errors for the 4DCT technique were: 0.00–0.68 deg in rotation; 0.02–0.30 mm in translation. Results are on the order of the reported accuracy of other image-based kinematic techniques.