Back to Authors

Fain, Sean B.

https://orcid.org/0000-0001-5461-0646

Mayo Clinic

University of Iowa

Citations 2

The Use of Computed Tomography Densitometry for the Assessment of Emphysema in Clinical Trials: A Position Paper from the Fleischner Society
Estépar, Raúl San Jośe , Barr, R. Graham, Fain, Sean B. , Hoffman, Eric A. , Humphries, Stephen M. , Obuchowski, Nancy A. , Ryerson, Christopher J. , Bankier, Alexander A. , Crapo, James D. , Han, Meilan, Kellermeyer, Liz , Newell, John D. , Miller, Bruce E. , Nordenmark, Lars H. , Rémy‐Jardin, Martine , Silverman, Edwin K. , Washko, George R. , Lynch, David A. , San Jose Estepar, Raul , Hoffman, Eric A , Humphries, Stephen M , Tal-Singer, Ruth , Ash, Samuel Y , Barr, R. Graham, Greniér, Philippe , Kirby, Miranda , Seo, Joon Beom , Tal‐Singer, Ruth , Han, MeiLan King , Goldin, Jonathan , McCollough, Cynthia H. , Prokop, Mathias , Ohno, Yoshiharu , Strange, Charlie

American Journal of Respiratory and Critical Care Medicine | March 24, 2025 | Volume: 211 | Issue: 5 | Pages: 709-728

10.1164/rccm.202410-2012so Get It

Abstract Emphysema’s significant morbidity and mortality underscore the need for reliable outcome metrics in clinical trials. However, commonly accepted chronic obstructive pulmonary disease outcome measures do not adequately capture emphysema severity or progression. Computed tomography (CT) metrics have been validated as accurate indicators of pathological emphysema and predictors of chronic obstructive pulmonary disease progression, exacerbations, and mortality. This position paper reviews the evidence supporting CT densitometry as a biomarker for emphysema, establishes implementation standards, and highlights areas for future research. A systematic literature review addressed three key questions: whether CT densitometry can be used as a diagnostic biomarker of emphysema, whether CT densitometry can be used as a prognostic biomarker, and whether longitudinal change in densitometry can be used as a disease progression monitoring biomarker. Emphysema metrics, such as the percentage of low attenuation areas below −950 Hounsfield units, are validated, highly reproducible diagnostic and prognostic biomarkers. Volume-adjusted lung density is recommended for disease monitoring. Both metrics demonstrate a scan–rescan intraclass correlation coefficient of 0.99 with proper technique. The paper also discusses relevant CT physics, techniques, and sources of variation, including technical factors, physiological changes, and software analysis. Key recommendations for clinical trials include using standardized CT techniques, proper subject selection, and longitudinal evaluation with volume-adjusted lung density.
Aortic Arch and Carotid Artery Single-Shot Gadolinium-Enhanced 3D MR Angiography with an Elliptical Centric Acquisition Order
Fain, Sean B. , Wilman, Alan H. , Riederer, Stephen J. , Huston, John

Rivista di Neuroradiologia | April 22, 2015 | Volume: 11 | Issue: 2_suppl | Pages: 179-183

10.1177/19714009980110s252 Get It

We sought to obtain high resolution 3D contrast-enhanced MR angiograms of the carotid arteries, vertebral arteries and aortic arch with venous signal suppression utilizing novel timing techniques. A secondary purpose was to compare contrast-enhanced MR angiograms with 2D time-of-flight MR angiograms of the carotid arteries.