Waveguide effects and implications for cardiac magnetic resonance elastography: A finite element study
Manduca, Armando , Rossman, Timothy, Lake, David S. , Glaser, Kevin J. , Arani, Arvin , Rossman, Phillip J. , Trzasko, Joshua D. , Dragomir‐Daescu, Dan , Araoz, Philip A. , Manduca, A , Arunachalam, S P , Arani, Arvin , Arunachalam, Shivaram P. , Ehman, Richard L.

NMR in Biomedicine | August 13, 2018 | Volume: 31 | Issue: 10 | Pages: No page available

10.1002/nbm.3996 | PMID 30101999 Get It

Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin‐walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal‐to‐noise ratio, and resolution will be required to achieve accurate results.
Incidence and Clinical Significance of New-Onset Device-Detected Atrial Tachyarrhythmia
Belkin, Mark N. , Soria, Cesar, Waldo, Albert L., Borleffs, C. Jan Willem, Hayes, David L. , Tung, Roderick , Upadhyay, Gaurav A. , Soria, Cesar E, Singh, Jagmeet P, Singh, Jagmeet P

Circulation: Arrhythmia and Electrophysiology | March 14, 2018 | Volume: 11 | Issue: 3 | Pages: No page available

10.1161/circep.117.005393 | PMID 29540371 Get It

Background: Despite the clear association between atrial fibrillation and risk for thromboembolic events (TEs), the clinical significance of new-onset device-detected atrial tachyarrhythmia (DDAT) and TE remains disputed. We aimed to determine the risk of TE in patients with new-onset DDAT. Methods and Results: The OVID Medline, Cochrane, and Scopus databases (inception to November 2016) were searched. Randomized controlled trials, prospective, or retrospective studies of pacemaker or defibrillator patients reporting incidence of DDAT were selected. Summary statistics were used for analysis. Of 4893 reports identified, 28 studies following 24 984 patients were included: average age 69.9 years, 34.7% women, mean study duration 21.8±18.6 months. New-onset DDAT was observed in 23% of patients. Among 9 studies (n=8181) reporting TE, the absolute incidence was 2.1%. TE risk was significantly greater among patients with new-onset DDAT (relative risk [RR], 2.88; 95% CI, 1.79–4.64; P <0.001). TE risk was correlated with DDAT duration, with an increased risk associated with DDAT ≥5 minutes (RR, 3.86; 95% CI, 2.04–7.30; P <0.001) compared with <1 minute (RR, 1.77; 95% CI, 1.15–2.74; P =0.01). Notably, the risk of TE was also increased in patients with adjudicated atrial electrograms (RR, 3.60; 95% CI, 2.06–6.30; P <0.001) compared with nonadjudicated electrograms (RR, 2.05; 95% CI, 1.06–3.97; P =0.03), even when lower mean thresholds for detection were used. Conclusions: New-onset DDAT is common, affecting close to one quarter of all patients with implanted pacemakers or defibrillators. Adjudication of atrial electrograms further identifies at-risk patients, even when relatively short detection thresholds are used.
Oversensing of transthoracic excitation stimuli in contemporary pacemakers
Ryan, J. , Tempel, Nathan D., Engle, Dean D., Hayes, David L. , Cha, Yong‐Mei , Asirvatham, Samuel J. , Ryan, James D , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | February 1, 2018 | Volume: 41 | Issue: 3 | Pages: 340-340

10.1111/pace.13290 | PMID 29388240 Get It

Oversensing of transthoracic excitation stimuli in contemporary pacemakers
Ryan, J. , Tempel, Nathan D., Engle, Dean D., Hayes, David L. , Cha, Yong‐Mei , Asirvatham, Samuel J. , Ryan, James D , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | January 10, 2018 | Volume: 41 | Issue: 2 | Pages: 161-166

10.1111/pace.13269 | PMID 29315719 Get It

AbstractBackgroundTransthoracic impedance measurements (TIM) is primarily used for minute ventilation rate adaptive sensors in pacemakers. With elevated impedance, the TIM electrical signal itself is oversensed, causing device malfunction.ObjectiveWe report an increased incidence of TIM oversensing.MethodRetrospective chart review. We review existing records of 18 patients who have demonstrated device malfunction with TIM oversensing.ResultsWe have found a 1.8% incidence of TIM‐related oversensing in our patient population of 959 patients with contemporary Boston Scientific (Marlborough, MA, USA) pacemakers and cardiac resynchronization therapy pacemakers. One patient experienced a syncopal episode.ConclusionOversensing with pacing inhibition is apparent with the potential of adverse effects to patients.
Cardiac MR elastography using reduced‐FOV, single‐shot, spin‐echo EPI
Sui, Yi , Arunachalam, Shivaram P. , Arani, Arvin , Trzasko, Joshua D. , Young, Phillip M. , Glockner, James F., Glaser, Kevin J. , Lake, David S. , McGee, Kiaran P. , Rossman, Phillip J. , Araoz, Philip A. , Arunachalam, S P , Arani, Arvin , Manduca, Armando , Ehman, Richard L. , Sui, Yi

Magnetic Resonance in Medicine | December 1, 2017 | Volume: 80 | Issue: 1 | Pages: 231-238

10.1002/mrm.27029 | PMID 29194738 Get It

PurposeTo implement a reduced field of view (rFOV) technique for cardiac MR elastography (MRE) and to demonstrate the improvement in image quality of both magnitude images and post‐processed MRE stiffness maps compared to the conventional full field of view (full‐FOV) acquisition.MethodsWith Institutional Review Board approval, 17 healthy volunteers underwent both full‐FOV and rFOV cardiac MRE scans using 140‐Hz vibrations. Two cardiac radiologists blindly compared the magnitude images and stiffness maps and graded the images based on several image quality attributes using a 5‐point ordinal scale. Fisher's combined probability test was performed to assess the overall evaluation. The octahedral shear strain‐based signal‐to‐noise ratio (OSS‐SNR) and median stiffness over the left ventricular myocardium were also compared.ResultsOne volunteer was excluded because of an inconsistent imaging resolution during the exam. In the remaining 16 volunteers (9 males, 7 females), the rFOV scans outperformed the full‐FOV scans in terms of subjective image quality and ghosting artifacts in the magnitude images and stiffness maps, as well as the overall preference. The quantitative measurements showed that rFOV had significantly higher OSS‐SNR (median: 1.4 [95% confidence interval (CI): 1.2–1.5] vs. 2.1 [95% CI: 1.8–2.4]), P < 0.05) compared to full‐FOV. Although no significant change was found in the median myocardial stiffness between the 2 scans, we observed a decrease in the stiffness variation within the myocardium from 2.1 kPa (95% CI: [1.9, 2.3]) to 1.9 kPa (95% CI: [1.7, 2.0]) for full‐FOV and rFOV, respectively (P < 0.05) in a subgroup of 7 subjects with ghosting present in the myocardium.ConclusionThis pilot volunteer study demonstrated that rFOV cardiac MRE has the capability to reduce ghosting and to improve image quality in both MRE magnitude images and stiffness maps. Magn Reson Med 80:231–238, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
269 Cardiac resynchronization therapy does not reduce the incidence of ventricular arrhythmias
Lin, Grace , Brady, Peter A. , Webster, Tracy L., Rea, Robert F., Hammill, Stephen C., Hayes, David L.

EP Europace | April 14, 2017 | Volume: 7 | Issue: Supplement_1 | Pages: 64-65

10.1016/eupace/7.supplement_1.64-b Get It

Regional assessment of in vivo myocardial stiffness using 3D magnetic resonance elastography in a porcine model of myocardial infarction
Arunachalam, Shivaram P. , Arani, Arvin , Baffour, Francis , Rysavý, J, Rossman, Phillip J. , Glaser, Kevin J. , Lake, David S. , Trzasko, Joshua D. , McGee, Kiaran P. , Araoz, Philip A. , Rysavy, Joseph A, Manduca, Armando , Ehman, Richard L. , Arunachalam, S P , Arani, Arvin , Baffour, Francis I

Magnetic Resonance in Medicine | April 6, 2017 | Volume: 79 | Issue: 1 | Pages: 361-369

10.1002/mrm.26695 | PMID 28382658 Get It

Purpose The stiffness of a myocardial infarct affects the left ventricular pump function and remodeling. Magnetic resonance elastography (MRE) is a noninvasive imaging technique for measuring soft‐tissue stiffness in vivo. The purpose of this study was to investigate the feasibility of assessing in vivo regional myocardial stiffness with high‐frequency 3D cardiac MRE in a porcine model of myocardial infarction, and compare the results with ex vivo uniaxial tensile testing. Methods Myocardial infarct was induced in a porcine model by embolizing the left circumflex artery. Fourteen days postinfarction, MRE imaging was performed in diastole using an echocardiogram‐gated spin‐echo echo‐planar‐imaging sequence with 140‐Hz vibrations and 3D MRE processing. The MRE stiffness and tensile modulus from uniaxial testing were compared between the remote and infarcted myocardium. Results Myocardial infarcts showed increased in vivo MRE stiffness compared with remote myocardium (4.6 ± 0.7 kPa versus 3.0 ± 0.6 kPa, P = 0.02) within the same pig. Ex vivo uniaxial mechanical testing confirmed the in vivo MRE results, showing that myocardial infarcts were stiffer than remote myocardium (650 ± 80 kPa versus 110 ± 20 kPa, P = 0.01). Conclusions These results demonstrate the feasibility of assessing in vivo regional myocardial stiffness with high‐frequency 3D cardiac MRE. Magn Reson Med 79:361–369, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Implantable Cardioverter Defibrillator Programming Characteristics, Shocked Rhythms, and Survival Among Patients Under Thirty Years of Age
Chang, Philip M. , Powell, Brian D. , Jones, Paul W. , Carter, Nathan , Hayes, David L. , Saxon, Leslie A.

Journal of Cardiovascular Electrophysiology | June 23, 2016 | Volume: 27 | Issue: 10 | Pages: 1183-1190

10.1111/jce.13038 | PMID 27334356 Get It

ICD Characteristics and Survival in Young PatientsIntroductionIndications for implantable cardioverter defibrillators (ICDs) in young patients have expanded and differ from those in older adults. We sought to provide descriptive characteristics and data regarding ICD therapy and outcomes among younger and older ICD recipients.Methods and ResultsDemographics, device type and programming, remotely transmitted data, shock events, and survival were compared among younger (≤30 years) and older (>30 years) cohorts with ICDs from a single manufacturer followed on a remote network. The younger cohort included 904 patients (1.6% of all implants). This group had more females (46% vs. 25%; P < 0.01), single‐coil leads (21% vs. 4%; P < 0.01), and single‐chamber devices (46% vs. 34%; P < 0.01). Shock incidence was higher (40% younger vs. 32% older at 4 years; P < 0.01) and survival was better over comparable follow‐up (88% vs. 72%; P < 0.01). Remote monitoring was associated with improved survival in both groups (93% vs. 86% ≤ 30 years, P < 0.01; 73% vs. 66% > 30 years, P < 0.01). Shock for polymorphic ventricular tachycardia/fibrillation (VT/VF) was more frequent in younger patients (12% vs. 5%; P < 0.01); 39% of all shocks were inappropriate. A 10‐fold increased risk of mortality was seen among young patients with shocks for atrial fibrillation/flutter (AF/AFL).ConclusionsDifferences in survival, shock incidence, and prognostic significance of VT/VF and AF/AFL exist between younger and older ICD recipients. These suggest distinct differences in myocardial substrates and diseases that ultimately impact ICD management.
Quantitative 3D magnetic resonance elastography: Comparison with dynamic mechanical analysis
Arunachalam, Shivaram P. , Rossman, Phillip J. , Arani, Arvin , Lake, David S. , Glaser, Kevin J. , Trzasko, Joshua D. , McGee, Kiaran P. , Araoz, Philip A. , Manduca, Armando , Ehman, Richard L. , Arunachalam, S P , Arani, Arvin

Magnetic Resonance in Medicine | March 26, 2016 | Volume: 77 | Issue: 3 | Pages: 1184-1192

10.1002/mrm.26207 | PMID 27016276 Get It

Purpose Magnetic resonance elastography (MRE) is a rapidly growing noninvasive imaging technique for measuring tissue mechanical properties in vivo. Previous studies have compared two‐dimensional MRE measurements with material properties from dynamic mechanical analysis (DMA) devices that were limited in frequency range. Advanced DMA technology now allows broad frequency range testing, and three‐dimensional (3D) MRE is increasingly common. The purpose of this study was to compare 3D MRE stiffness measurements with those of DMA over a wide range of frequencies and shear stiffnesses. Methods 3D MRE and DMA were performed on eight different polyvinyl chloride samples over 20–205 Hz with stiffness between 3 and 23 kPa. Driving frequencies were chosen to create 1.1, 2.2, 3.3, 4.4, 5.5, and 6.6 effective wavelengths across the diameter of the cylindrical phantoms. Wave images were analyzed using direct inversion and local frequency estimation algorithm with the curl operator and compared with DMA measurements at each corresponding frequency. Samples with sufficient spatial resolution and with an octahedral shear strain signal‐to‐noise ratio > 3 were compared. Results Consistency between the two techniques was measured with the intraclass correlation coefficient (ICC) and was excellent with an overall ICC of 0.99. Conclusions 3D MRE and DMA showed excellent consistency over a wide range of frequencies and stiffnesses. Magn Reson Med 77:1184–1192, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.