Back to Authors

Upadhyay, Gaurav A.

https://orcid.org/0000-0002-3493-2100

Mayo Clinic

University of Chicago

Citations 2

Predictors of Shock‐Reduction Programming and Its Impact on Implantable Cardioverter‐Defibrillator Therapies and Mortality: The CERTITUDE Registry
Beyer, Sebastian E. , Harrell, Camden , Mullane, Steven , Kutyifa, Valentina , Madhavan, Malini , Piccini, Jonathan P. , Upadhyay, Gaurav A. , Ip, James E. , Thomas, George , Liu, Christopher F. , Markowitz, Steven M. , Hayes, David L. , Lerman, Bruce B. , Cheung, Jim W , Cheung, Jim W.

Journal of the American Heart Association | July 16, 2024 | Volume: 13 | Issue: 15 | Pages: No page available

10.1161/jaha.124.034500 Get It

Background Shock‐reduction implantable cardioverter‐defibrillator programming (SRP) was associated with fewer therapies and improved survival in randomized controlled trials, but real‐world studies investigating SRP and associated outcomes are limited. Methods and Results The BIOTRONIK CERTITUDE registry was linked with the Medicare database. We included all patients with an implantable cardioverter‐defibrillator implanted between August 22, 2012 and September 30, 2021 in the United States. SRP was defined as programming to either a therapy rate cutoff ≥188 beats per minute or number of intervals to detection ≥30/40 for treatment. Among 6781 patients (mean 74±9 years; 27% women), 3393 (50%) had SRP. Older age, secondary prevention indication, and device implantation in the southern or western United States were associated with lower use of SRP. The cumulative incidence rate of implantable cardioverter‐defibrillator shocks was lower in the SRP group (5.1% shocks/patient year) compared with the non‐SRP group (7.2% shocks/patient year) (adjusted hazard ratio [HR], 0.83 [95% CI, 0.73–0.96]; P =0.005). Over a median follow‐up of 2.9 years, 739 deaths occurred in the SRP group and 822 deaths occurred in the non‐SRP group (adjusted HR, 0.97 [95% CI, 0.88–1.07]; P =0.569). SRP was associated with a lower all‐cause mortality among patients without ischemic heart disease compared with patients with ischemic heart disease (adjusted HR, 0.64 [95% CI, 0.48–0.87] versus adjusted HR, 1.02 [95% CI, 0.92–1.14]; P interaction =0.004). Conclusions Adoption of SRP is low in real‐world clinical practice. Age, clinical variables, and geographic factors are associated with use of SRP. In this study, SRP‐associated decrease in mortality was limited to patients without ischemic heart disease.
Incidence and Clinical Significance of New-Onset Device-Detected Atrial Tachyarrhythmia
Belkin, Mark N. , Soria, Cesar, Waldo, Albert L., Borleffs, C. Jan Willem, Hayes, David L. , Tung, Roderick , Upadhyay, Gaurav A. , Soria, Cesar E, Singh, Jagmeet P, Singh, Jagmeet P

Circulation: Arrhythmia and Electrophysiology | March 14, 2018 | Volume: 11 | Issue: 3 | Pages: No page available

10.1161/circep.117.005393 Get It

Background: Despite the clear association between atrial fibrillation and risk for thromboembolic events (TEs), the clinical significance of new-onset device-detected atrial tachyarrhythmia (DDAT) and TE remains disputed. We aimed to determine the risk of TE in patients with new-onset DDAT. Methods and Results: The OVID Medline, Cochrane, and Scopus databases (inception to November 2016) were searched. Randomized controlled trials, prospective, or retrospective studies of pacemaker or defibrillator patients reporting incidence of DDAT were selected. Summary statistics were used for analysis. Of 4893 reports identified, 28 studies following 24 984 patients were included: average age 69.9 years, 34.7% women, mean study duration 21.8±18.6 months. New-onset DDAT was observed in 23% of patients. Among 9 studies (n=8181) reporting TE, the absolute incidence was 2.1%. TE risk was significantly greater among patients with new-onset DDAT (relative risk [RR], 2.88; 95% CI, 1.79–4.64; P <0.001). TE risk was correlated with DDAT duration, with an increased risk associated with DDAT ≥5 minutes (RR, 3.86; 95% CI, 2.04–7.30; P <0.001) compared with <1 minute (RR, 1.77; 95% CI, 1.15–2.74; P =0.01). Notably, the risk of TE was also increased in patients with adjudicated atrial electrograms (RR, 3.60; 95% CI, 2.06–6.30; P <0.001) compared with nonadjudicated electrograms (RR, 2.05; 95% CI, 1.06–3.97; P =0.03), even when lower mean thresholds for detection were used. Conclusions: New-onset DDAT is common, affecting close to one quarter of all patients with implanted pacemakers or defibrillators. Adjudication of atrial electrograms further identifies at-risk patients, even when relatively short detection thresholds are used.