INTRODUCTION: The performance of a high quality esophagogastroduodenoscopy (EGD) is dependent on the mucosal cleanliness. Recently, the Polprep: Effective Assessment of Cleanliness in EGD (PEACE) scale was created to assess the degree of mucosal cleanliness during EGD. The aim of this study was to validate this scoring system in a cohort of international endoscopists. METHODS: In total, 39 EGD videos, with different degrees of mucosal cleanliness were retrieved from a previously conducted prospective trial. All experts rated the cleanliness of the mucosa on each video using the PEACE scale. To evaluate agreement of all scores (0–3), intraclass correlation coefficient 2.1 was used. The agreement on adequate (scores 2 and 3) and inadequate (scores 0 and 1) cleanliness was assessed using kappa values. RESULTS: Videos evaluating esophagus, stomach, and duodenum cleanliness were reviewed by 16 endoscopists. The PEACE scores demonstrated good agreement (intraclass correlation coefficient 0.82, 95% CI 0.75–0.89), especially for esophagus (0.84; 95% CI 0.71–0.95) and stomach (0.81; 95% CI 0.69–0.91), while agreement was moderate for the duodenum (0.69; 95% CI 0.51–0.87). The agreement was similar between Eastern (0.86; 95% CI 0.79–0.92) and Western experts (0.80; 95% CI 0.72–0.88). Similarly, agreement regarding adequate cleanliness was comparable between Eastern (0.70; 95% CI 0.55–0.85) and Western (0.74; 95% CI 0.64–0.84) endoscopists being overall 0.75 (95% CI 0.65–0.85). DISCUSSION: The PEACE scoring system is a simple and reliable scale to assess the cleanliness during EGD. The score is now validated among international experts with high concordance, justifying its use in clinical practice.
S463 The Role of Generative Language Systems in Increasing Patient Awareness of Colon Cancer Screening
Background Piecemeal endoscopic mucosal resection (EMR) is an acceptable technique for T1a esophageal adenocarcinoma, but en bloc R0 excision is advocated for T1b disease as it may offer a potential cure and mitigate recurrence. Thus, distinguishing between T1a and T1b disease is imperative under current treatment paradigms. We investigated whether expert Barrett’s endoscopists could make this distinction based on optical evaluation. Methods Endoscopic images of histologically confirmed high grade dysplasia (HGD), T1a, and T1b disease (20 sets for each) were compiled from consecutive patients at a single institution. Each set contained four images including an overview, a close-up in high definition white light, a near-focus magnification image, and a narrow-band image. Experts predicted the histology for each set. Results 19 experts from 8 countries (Australia, USA, Italy, Netherlands, Germany, Canada, Belgium, and Portugal) participated. The majority had been practicing for > 20 years, with a median (interquartile range) annual case volume of 50 (18–75) for Barrett’s EMR and 25 (10–45) for Barrett’s endoscopic submucosal dissection. Esophageal adenocarcinoma (T1a/b) could be distinguished from HGD with a pooled sensitivity of 89.1 % (95 %CI 84.7–93.4). T1b adenocarcinoma could be predicted with a pooled sensitivity of 43.8 % (95 %CI 29.9–57.7). Fleiss’ kappa was 0.421 (95 %CI 0.399–0.442; P < 0.001), indicating fair-to-moderate agreement. Conclusions Expert Barrett’s endoscopists could reliably differentiate T1a/T1b esophageal adenocarcinoma from HGD. Despite fair-to-moderate agreement for T staging, T1b disease could not be reliably distinguished from T1a disease. This may impact clinical decision making and selection of endoscopic techniques.
International validation of a PEACE scale assessing cleanliness during esophagogastroduodenoscopy to improve the quality of inspection during endoscopy
Abstract Background Current guidelines recommend endoscopic resection of visible and endoscopically resectable colorectal colitis-associated neoplasia (CAN) in patients with inflammatory bowel disease (IBD). However, patients with high risk CAN are often not amenable to conventional resections techniques and a consensus approach for the endoscopic management of these lesions is presently lacking. This Delphi study aims to reach consensus amongst experts on the endoscopic management of these lesions. Methods A three-round modified Delphi process was conducted to reach consensus amongst worldwide IBD and/or endoscopy experts (n=18) from three continents. Experts were chosen based on the extensive clinical experience with IBD and/or EMR/ESD in patients with IBD, and the authorship on multiple peer-reviewed publications on CAN, the endoscopic resection of CAN and/or EMR/ESD. Consensus was considered if ≥ 75% agreed or disagreed. Quality of evidence was assessed by the criteria of the Cochrane Collaboration group. Results Consensus was reached on all statements (n=14). Experts agreed on a definition for CAN and high-risk CAN (HR-CAN). Consensus was reached on the examination of the colon with enhanced endoscopic imaging prior to resection, the endoscopic resectability of a HR-CAN lesion and endoscopic assessment and standard report of CAN lesions. In addition, experts agreed on type of resections of HR-CAN (< 20mm, >20 mm, with or without good lifting), endoscopic success (technical success and outcomes), histologic assessment and follow-up in HR-CAN. Conclusion This is the first step in developing international consensus-based recommendations for endoscopic management of (HR-)CAN. Although the quality of available evidence was considered low, consensus was reached on several aspects of the management of (HR-)CAN. The present work and proposed standardization might benefit future studies.
Performance measures for colonoscopy in inflammatory bowel disease patients: European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative
AbstractThe European Society of Gastrointestinal Endoscopy (ESGE) presents a short list of performance measures for colonoscopy in inflammatory bowel disease (IBD) patients. Current performance measures for colonoscopy mainly focus on detecting (pre)malignant lesions. However, these performance measures are not relevant for all colonoscopy indications in IBD patients. Therefore, our aim was to provide endoscopy services across Europe and other interested countries with a tool for quality monitoring and improvement in IBD colonoscopy. Eight key performance measures and one minor performance measure were recommended for measurement and evaluation in daily endoscopy practice.
Definition of competence standards for optical diagnosis of diminutive colorectal polyps: European Society of Gastrointestinal Endoscopy (ESGE) Position Statement
Abstract Background The European Society of Gastrointestinal Endoscopy (ESGE) has developed a core curriculum for high quality optical diagnosis training for practice across Europe. The development of easy-to-measure competence standards for optical diagnosis can optimize clinical decision-making in endoscopy. This manuscript represents an official Position Statement of the ESGE aiming to define simple, safe, and easy-to-measure competence standards for endoscopists and artificial intelligence systems performing optical diagnosis of diminutive colorectal polyps (1 – 5 mm). Methods A panel of European experts in optical diagnosis participated in a modified Delphi process to reach consensus on Simple Optical Diagnosis Accuracy (SODA) competence standards for implementation of the optical diagnosis strategy for diminutive colorectal polyps. In order to assess the clinical benefits and harms of implementing optical diagnosis with different competence standards, a systematic literature search was performed. This was complemented with the results from a recently performed simulation study that provides guidance for setting alternative competence standards for optical diagnosis. Proposed competence standards were based on literature search and simulation study results. Competence standards were accepted if at least 80 % agreement was reached after a maximum of three voting rounds. Recommendation 1 In order to implement the leave-in-situ strategy for diminutive colorectal lesions (1–5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 90 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1–5 mm in the rectosigmoid. Histopathology is used as the gold standard. Level of agreement 95 %. Recommendation 2 In order to implement the resect-and-discard strategy for diminutive colorectal lesions (1–5 mm), it is clinically acceptable if, during real-time colonoscopy, at least 80 % sensitivity and 80 % specificity is achieved for high confidence endoscopic characterization of colorectal neoplasia of 1–5 mm. Histopathology is used as the gold standard. Level of agreement 100 %. Conclusion The developed SODA competence standards define diagnostic performance thresholds in relation to clinical consequences, for training and for use when auditing the optical diagnosis of diminutive colorectal polyps.
Establishing key research questions for the implementation of artificial intelligence in colonoscopy: a modified Delphi method
Abstract Background Artificial intelligence (AI) research in colonoscopy is progressing rapidly but widespread clinical implementation is not yet a reality. We aimed to identify the top implementation research priorities. Methods An established modified Delphi approach for research priority setting was used. Fifteen international experts, including endoscopists and translational computer scientists/engineers, from nine countries participated in an online survey over 9 months. Questions related to AI implementation in colonoscopy were generated as a long-list in the first round, and then scored in two subsequent rounds to identify the top 10 research questions. Results The top 10 ranked questions were categorized into five themes. Theme 1: clinical trial design/end points (4 questions), related to optimum trial designs for polyp detection and characterization, determining the optimal end points for evaluation of AI, and demonstrating impact on interval cancer rates. Theme 2: technological developments (3 questions), including improving detection of more challenging and advanced lesions, reduction of false-positive rates, and minimizing latency. Theme 3: clinical adoption/integration (1 question), concerning the effective combination of detection and characterization into one workflow. Theme 4: data access/annotation (1 question), concerning more efficient or automated data annotation methods to reduce the burden on human experts. Theme 5: regulatory approval (1 question), related to making regulatory approval processes more efficient. Conclusions This is the first reported international research priority setting exercise for AI in colonoscopy. The study findings should be used as a framework to guide future research with key stakeholders to accelerate the clinical implementation of AI in endoscopy.
Recovery of endoscopy services in the era of COVID-19: recommendations from an international Delphi consensus
The COVID-19 pandemic has had a profound impact on provision of endoscopy services globally as staff and real estate were repurposed. As we begin to recover from the pandemic, a cohesive international approach is needed, and guidance on how to resume endoscopy services safely to avoid unintended harm from diagnostic delays. The aim of these guidelines is to provide consensus recommendations that clinicians can use to facilitate the swift and safe resumption of endoscopy services. An evidence-based literature review was carried out on the various strategies used globally to manage endoscopy during the COVID-19 pandemic and control infection. A modified Delphi process involving international endoscopy experts was used to agree on the consensus statements. A threshold of 80% agreement was used to establish consensus for each statement. 27 of 30 statements achieved consensus after two rounds of voting by 34 experts. The statements were categorised as pre-endoscopy, during endoscopy and postendoscopy addressing relevant areas of practice, such as screening, personal protective equipment, appropriate environments for endoscopy and infection control precautions, particularly in areas of high disease prevalence. Recommendations for testing of patients and for healthcare workers, appropriate locations of donning and doffing areas and social distancing measures before endoscopy are unique and not dealt with by any other guidelines. This international consensus using a modified Delphi method to produce a series of best practice recommendations to aid the safe resumption of endoscopy services globally in the era of COVID-19.