Background: Rupture at tendon repair sites in animal models impedes the study of healing. To address this, we investigated “safe incisions” – strategic partial transections to prevent rupture under excessive force. We hypothesized these would act as mechanical “fuses,” reducing repair site tension. Objectives: This in vitro biomechanical study optimized safe incision spacing to enhance tendon construct strength and minimize gap formation in a turkey flexor tendon model. Materials and Methods: Forty turkey flexor tendons were divided into five groups ( n = 8): Repaired without incisions, intact with 5 mm incisions, repaired with 5 mm incisions, intact with 10 mm incisions, and repaired with 10 mm incisions. Repairs used a modified Pennington suture. Safe incisions (opposing hemi-transections) with 5 mm or 10 mm longitudinal spacing were created proximally. Tendons were tested to failure at 1 mm/s, recording force-elongation, failure mode, gap formation (>2 mm at 10% strain), stiffness, and repair site elongation. Results: Repaired tendons without incisions (Group 1) showed 100% repair site failure (46.5 ± 10.96 N). With 5 mm safe incisions (Group 3), no repair site failures occurred (incision failure at 18.11 ± 10.96 N). 10 mm incisions (Group 5) offered partial protection (25% repair failure at 37.48 ± 11.35 N). Group 1 had higher gap formation (75% vs. 0% in Group 3, P < 0.01), stiffness, and repair site elongation than Groups 3 and 5. Gap formation force was similar for Group 1 (25.76 ± 9.18 N) and Group 5 (25.04 ± 12.21 N). Conclusions: In this in vitro model, 5 mm spaced safe incisions effectively shifted failure away from the repair and limited gap formation by reducing stiffness. 10 mm incisions provided partial protection. Strategically placed safe incisions show potential to protect tendon repairs from immediate rupture by enabling controlled lengthening at a weaker site. However, tendinopathy risk and clinical relevance require in vivo studies.
The effect of the number of strands and knot throws of core suture techniques on the mechanical properties of the repaired flexor tendon
Abstract Flexor tendon injury is a common hand trauma that requires surgical repair. The objective was to compare the repaired strength and gliding resistance with a varied number of repair strands and of square knots using a two‐strand‐overhand locking (TSOL) knot. First, isolated suture loops with different number of suture strands and number of closing knots were compared in mechanical strength and failure mode. Then, 90 flexor digitorum profundus (FDP) tendons from turkey digits were used for the tendon repair experiment. Both phases followed a similar 3 × 3 matrix comparing the knot type including TSOL+1SK (square knot), TSOL+2SK, and TSOL+3 SK and repair techniques including two‐, four‐, and six‐strand repairs techniques respectively. The repaired tendons were tested for tendon resistance against pulley (friction), maximum force, force at 2 mm displacement, stiffness, and failure mode. Increasing the number of strands and closing square knots increases the tensile strength and stiffness of flexor tendon repairs and isolated suture loops without a significant effect on tendon friction. An increase in the number of square knots have shown increased strength only in Pennington repair, which correlated with the increased number of knot unraveling, a weak knot failure model. Our data demonstrated that increasing the number of strands is effective for improving the overall strength of tendon repair. When a two‐strand repair is chosen, increasing knot number can improve repair strength. However, the number of knots appears not affecting repair strength in six‐strand repair technique.
McArdle’s sign: a specific sign of multiple sclerosis (P1.087)
Aims Options for the treatment of intra-articular ligament injuries are limited, and insufficient ligament reconstruction can cause painful joint instability, loss of function, and progressive development of degenerative arthritis. This study aimed to assess the capability of a biologically enhanced matrix material for ligament reconstruction to withstand tensile forces within the joint and enhance ligament regeneration needed to regain joint function. Materials and Methods A total of 18 New Zealand rabbits underwent bilateral anterior cruciate ligament reconstruction by autograft, FiberTape, or FiberTape-augmented autograft. Primary outcomes were biomechanical assessment (n = 17), microCT (µCT) assessment (n = 12), histological evaluation (n = 12), and quantitative polymerase chain reaction (qPCR) analysis (n = 6). Results At eight weeks, FiberTape alone or FiberTape-augmented autograft demonstrated increased biomechanical stability compared with autograft regarding ultimate load to failure (p = 0.035), elongation (p = 0.006), and energy absorption (p = 0.022). FiberTape-grafted samples also demonstrated increased bone mineral density in the bone tunnel (p = 0.039). Histological evaluation showed integration of all grafts in the bone tunnels by new bone formation, and limited signs of inflammation overall. A lack of prolonged inflammation in all samples was confirmed by quantification of inflammation biomarkers. However, no regeneration of ligament-like tissue was observed along the suture tape materials. Except for one autograft failure, no adverse events were detected. Conclusion Our results indicate that FiberTape increases the biomechanical performance of intra-articular ligament reconstructions in a verified rabbit model at eight weeks. Within this period, FiberTape did not adversely affect bone tunnel healing or invoke a prolonged elevation in inflammation. Cite this article: Bone Joint J 2019;101-B:1238–1247.
Effect of Direct Electrical Current on Bones Infected with Staphylococcus epidermidis
Background: Joint incongruity in posteromedial rotatory instability (PMRI) has been theorized to determine early articular degenerative changes. Our hypothesis was that the articular contact area and contact pressure differ significantly between an intact elbow and an elbow affected by PMRI. Methods: Seven cadaveric elbows were tested under gravity varus stress using a custom-made machine designed to simulate muscle loads and allow passive elbow flexion (0° to 90°). The mean contact area and contact pressure data were collected and processed using the Tekscan sensor and software. After testing the intact specimen (intact elbow), a PMRI injury was simulated (PMRI elbow) and the specimen was tested again. Results: The PMRI elbows were characterized by initial joint subluxation and significantly elevated articular contact pressure. Both worsened, corresponding with a reduction in contact area, as the elbow was flexed from 0° until the joint subluxation and incongruity spontaneously reduced (at a mean [and standard error] of 60° ± 5° of flexion), at which point the mean contact pressure decreased from 870 ± 50 kPa (pre-reduction) to 440 ± 40 kPa (post-reduction) (p < 0.001) and the mean contact area increased from 80 ± 8 mm 2 to 150 ± 58 mm 2 (p < 0.001). This reduction of the subluxation was also followed by a shift of the contact area from the coronoid fracture edge toward the lower portion of the coronoid. At the flexion angle at which the PMRI elbows reduced, both the contact area and the contact pressure of the intact elbows differed significantly from those of the PMRI elbows, both before and after the elbow reduction (p < 0.001). Conclusions: The reduction in contact area and increased contact pressures due to joint subluxation and incongruity could explain the progressive arthritis seen in some elbows affected by PMRI. Clinical Relevance: This biomechanical study suggests that the early degenerative changes associated with PMRI reported in the literature could be subsequent to joint incongruity and an increase in contact pressure between the coronoid fracture surface and the trochlea.
Validation of a dynamic joint contracture measuring device in a live rabbit model of arthrofibrosis
AbstractTendon graft healing in bone tunnels for the fixation of intra‐articular ligament reconstructions may limit clinical outcome by delaying healing. This study assesses the effects of hydrogel‐mediated delivery of bone anabolic growth factors in a validated model of tendon‐to‐bone tunnel healing. Forty‐five Wistar rats were randomly allocated into three groups (BMP2‐treated, GSK126‐treated, and placebo). All animals underwent a tendon‐to‐bone tunnel reconstruction. Healing was evaluated at 4 weeks by biomechanical assessment, micro‐computed tomography (bone mineral density, bone volume, cross sectional area of bone tunnels), and traditional histology. Adverse events associated with the hydrogel‐mediated delivery of drugs were not observed. Results of our biomechanical assessment demonstrated favorable trends in animals treated with bone anabolic factors for energy absorption (P = 0.116) and elongation (P = 0.054), while results for force to failure (P = 0.691) and stiffness (P = 0.404) did not show discernible differences. Cross sectional areas for BMP2‐treated animals were reduced, but neither BMP2 nor GSK126 administration altered bone mineral density (P = 0.492) or bone volume in the bone tunnel. These results suggest a novel and positive effect of bone anabolic factors on tendon‐to‐bone tunnel healing. Histological evaluation confirmed absence of collagen fibers crossing the soft tissue‐bone interface indicating immature graft integration as expected at this time point. Our study indicates that hydrogel‐mediated delivery of BMP2 and GSK126 appears to be safe and has the potential to enhance tendon‐to‐bone tunnel healing in ligament reconstructions.
Effect of Off-Axis Fluoroscopy Imaging on Two-Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study
Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion–extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar–sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2–S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17–0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion–extension are likely robust, even when patient alignment is not perfect.
Evaluation of Fracture Resistance in Aqueous Environment under Dynamic Loading of Lithium Disilicate Restorative Systems for Posterior Applications. Part 2
AbstractPurposeThe goals of part 2 of the study presented here were 1) to assess whether there is a difference in failure mode of different thicknesses (2.0, 1.5, 1.0, and 0.5 mm) of anatomically standardized full contour monolithic lithium disilicate restorations for posterior teeth, and 2) to assess if there is a difference among various crown thicknesses when these restorations are subjected to dynamic load forces common for posterior teeth.Materials and MethodsFour groups (n = 10), each with a different thickness of anatomically appropriate all‐ceramic crowns, were to be tested as established from the statistical analysis of the preliminary phase. Group 1: 2.0 mm; group 2: 1.5 mm; group 3: 1.0 mm; group 4: 0.5 mm. The specimens were adhesively luted to the corresponding die, and underwent dynamic cyclic loading (380 to 390 N) completely submerged in an aqueous environment until a failure was noted by graphic recording and continuous monitoring.ResultsThere was a statistically significant difference of the fatigue cycles to failure among four groups (p < 0.001; Kruskal‐Wallis test). The mean number of cycles to fail for 2.0 mm specimens was 17 times more than the mean number of cycles to fail for 1.0 mm specimens and 1.5 times more than the mean number of cycles to fail for 1.5 mm specimens. The 0.5 mm specimens failed with one cycle of loading. A qualitative characteristic noted among the 2.0 mm specimens was wear of the area of indenter contact followed by shearing of the material and/or crack propagation.ConclusionBased on the findings of this study, it may be reasonable to consider a crown thickness of 1.5 mm or greater for clinical applications of milled monolithic lithium disilicate crowns for posterior single teeth.