Back to Authors

Gay, Ralph E.

https://orcid.org/0000-0002-0257-6228

Mayo Clinic

Mayo Clinic

Citations 7

Quantitative Shear Wave Speed Assessment for Muscles With the Diagnosis of Taut Bands and/or Myofascial Trigger Points Using Probe Oscillation Shear Wave Elastography: A Pilot Study
Lok, U‐Wai , Zhou, Chenyun , Tang, Shanshan , Madson, Timothy J., Gay, Ralph E. , Chen, Shigao , Yang, Lulu, Ling, Wenwu, Gong, Ping , Lok, U-Wai , Huang, Chengwu , Yang, Lulu , Ling, Wenwu , Gong, Ping , Jensen, Mark A.

Journal of Ultrasound in Medicine | June 4, 2021 | Volume: 41 | Issue: 4 | Pages: 845-854

10.1002/jum.15764 Get It

ObjectiveTo use probe oscillation shear wave elastography (PROSE) with two vibration sources to generate two shear waves in the imaging plane to quantitatively assess the shear wave speeds (SWSs) of muscles with and without the diagnosis of taut bands (TB) and/or myofascial trigger points (MTrPs).MethodsThirty‐three patients were scanned with the PROSE technique. Shear waves were generated through continuous vibration of the ultrasound probe, while the shear wave motions were detected using the same probe. SWSs for the sides with and without TBs and/or MTrPs were computed and compared. The pressure pain thresholds (PPTs) were measured as an indicator of maximum pain tolerance of patients. The statistical differences between the SWSs with and without TBs and/or MTrPs with different PPT values were analyzed using the nonparametric Wilcoxon rank‐sum test.ResultsThe mean SWSs for the sides with TBs and/or MTrPs are faster than that of the contralateral side without TBs and/or MTrPs. A significant difference was observed between mean SWSs with and without TBs and/or MTrPs without any information of PPT, with rank‐sum test P < .005. Additionally, with the information of PPT, a significant difference was observed between mean SWSs for the sides with and without TBs and/or MTrPs, for PPT values between 0 and 50 N/cm2 (P < .005), but for PPT values between 50 and 90 N/cm2, it was difficult to differentiate mean SWSs with and without TBs and/or MTrPs.ConclusionOur preliminary results show that SWSs measured from patients had a significant difference between the mean SWSs with and without TBs and/or MTrPs.
Effect of Off-Axis Fluoroscopy Imaging on Two-Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study
Zhao, Kristin D. , Ben‐Abraham, Ephraim I., Magnuson, Dixon J., Camp, Jon J. , Berglund, Lawrence J., An, Kai‐Nan , Brønfort, Gert , Gay, Ralph E. , Trentadue, Taylor P

Journal of Biomechanical Engineering | March 14, 2016 | Volume: 138 | Issue: 5 | Pages: No page available

10.1115/1.4032995 Get It

Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion–extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar–sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2–S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17–0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion–extension are likely robust, even when patient alignment is not perfect.
Poster 477 Cervical Radiculopathy Secondary to Metastatic Non‐Hodgkin's Lymphoma: A Case Report
Evangelista, Augustus P., Gay, Ralph E.

PM&R | September 29, 2014 | Volume: 6 | Issue: 9S | Pages: No page available

10.1016/j.pmrj.2014.08.846 Get It

Biomechanical Effects of Chiropractic-Based Distraction Therapy on the Behavior of Healthy and Degenerated Cervical Discs: A Finite Element Model Analysis
Hussain, Mozammil, Gay, Ralph E. , An, Kai‐Nan , Tepe, Rodger

ASME 2009 Summer Bioengineering Conference, Parts A and B | July 19, 2013 | Volume: No volume available | Issue: No issue available | Pages: 1253-1254

10.1115/sbc2009-206721 Get It

Many neck pain complaints are associated with degenerated discs in cervical spine. Disc degeneration (DD) consists of cascading stages of events with complex changes in disc tissue properties. This results in deterioration of the ability of the disc to perform its function normally. Several biomechanical and biochemical changes occur in the disc with degeneration. Increase in motion segment stiffness and peak stresses in the posterior annulus are some of the gross changes that occur in the disc with degeneration.
Disc Biomechanical Response due to Incomplete Length of Collagen Fibers in Various Regions of Annulus Fibrosus: A Finite Element Investigation
Hussain, Mozammil, Gay, Ralph E. , An, Kai‐Nan

ASME 2010 Summer Bioengineering Conference, Parts A and B | July 15, 2013 | Volume: No volume available | Issue: No issue available | Pages: 167-168

10.1115/sbc2010-19143 Get It

Collagen fibers in the annulus fibrosus (AF) play a significant role in maintaining the disc mechanical behavior. In healthy discs, AF fibers are concentrically arranged in a zigzag fashion. Tensile loads are transmitted to these fibers when the disc is loaded in compression. As a result, disc bulging occurs. Initiation and progression of mild cervical disc degeneration (DD) has been the subject of clinical concern [1]. The mild DD is associated with structural interruption in laminar organization of fibers in partial AF regions and incomplete length of fibers is a major form of structural interruption in AF fibers [2]. Moreover, a loss of lamellar fiber structure contributes to the progression of spinal deformity [3]. Past research have documented the biomechanical role of complete length of fibers in governing a healthy disc behavior [4]; however, there is a lack of clear understanding as to how incomplete length of fibers in different AF regions affect overall disc biomechanics and how they may play a role in initiating the propagation of DD. The focus of the current study is to investigate the disc biomechanical response due to incomplete length of fibers in outer, middle, and inner AF regions.
Transverse connectors providing increased stability to the cervical spine rod-screw construct: an in vitro human cadaveric study
Shaw, Miranda N., Morel, É., UTTER, PHILLIP ANDREW, Gussous, Yazeed M., Ginoux, Lise, Berglund, Lawrence J., Gay, Ralph E. , Krauss, William E.

Journal of Neurosurgery: Spine | March 11, 2011 | Volume: 14 | Issue: 6 | Pages: 719-725

10.3171/2011.1.spine10411 Get It

Object The object of this study was to determine if the addition of transverse connectors (TCs) to a rod-screw construct leads to increased stabilization of the cervical spine. Methods Eleven human cadaveric cervical spines (C2–T1) were used to examine the effect of adding connectors to a C3–7 rod-screw construct in 3 models of instability: 1) C3–6 wide laminectomy, 2) wide laminectomy and 50% foraminotomy at C4–5 and C5–6, and 3) wide laminectomy with full medial to lateral foraminotomy. Following each destabilization procedure, specimens were tested with no TC, 1 TC between the C-5 screws, and 2 TCs between the C-4 and C-6 screws. Testing of the connectors was conducted in random order. Specimens were subjected to ± 2 Nm of torque in flexion and extension, lateral bending, and axial rotation. Range of motion was determined for each experimental condition. Statistical comparisons were made between the destabilized and intact conditions, and between the addition of TCs and the absence of TCs. Results The progressive destabilization procedures significantly increased motion. The addition of TCs did not significantly change motion in flexion and extension. Lateral bending was significantly decreased with 2 connectors, but not with 1 connector. The greatest effect was on axial rotation. In general, 2 TCs were more restrictive than 1 TC, and decreased motion 10% more than fixation alone. Conclusions Regardless of the degree of cervical destabilization, 1 or 2 TCs decreased motion compared with rods and screws alone. Axial rotation was most affected. Transverse connectors effectively increase the rigidity of rod-screw constructs in the cervical spine. Severe cervical instability can be overcome with the use of 2 TCs, but in cases in which 2 cannot be used, 1 should be adequate and superior to none.
THE RELIABILITY OF INTRADISCAL STRESS PROFILOMETRY IN CADAVERIC LUMBAR DISCS
Gay, Ralph E. , Ilharreborde, Brice , Bridges, Jonathan, An, Kai‐Nan , Zhao, Kristin D.

Journal of Musculoskeletal Research | July 18, 2007 | Volume: 10 | Issue: 04 | Pages: 163-171

10.1142/s0218957706001844 Get It

The measurement of intradiscal stress has been primarily limited to nucleus pulposus pressure. Intradiscal stress profilometry is a technique that measures stress in both the nucleus pulposus (hydrostatic) and annulus fibrosus (compression). Evidence from animal studies suggests that distraction may affect disc physiology and promote repair. A study was performed to determine the reliability of intradiscal stress profilometry measurements in the anterior, posterior, and nucleus regions of cadaveric lumbar discs. Four fresh-frozen human lumbar motion segments were prepared and tested. Five profiles were obtained during two conditions of compression and three conditions of distraction. Discs were then graded for degenerative change. Reliability was judged by within-specimen coefficients of variation. The coefficients of variation were smaller (more reliable) for compression conditions than for distraction conditions. Within-specimen coefficients during compression ranged from 1.58% to 37.2% in the nucleus, 3.9% to 67.4% in the anterior annulus, and 2.3% to 25.5% in the posterior annulus. The reliability of intradiscal stress profilometry is acceptable for repeated measures studies evaluating within-specimen changes, but the sample size will vary depending on the test conditions used and the disc region of interest.