Effect of Off-Axis Fluoroscopy Imaging on Two-Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study
Zhao, Kristin D. , Ben‐Abraham, Ephraim I., Magnuson, Dixon J., Camp, Jon J. , Berglund, Lawrence J., An, Kai‐Nan , Brønfort, Gert , Gay, Ralph E. , Trentadue, Taylor P

Journal of Biomechanical Engineering | March 14, 2016 | Volume: 138 | Issue: 5 | Pages: No page available

10.1115/1.4032995 Get It

Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion–extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar–sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2–S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17–0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion–extension are likely robust, even when patient alignment is not perfect.
Feasibility of using 3D MR elastography to determine pancreatic stiffness in healthy volunteers
Shi, Yu , Glaser, Kevin J. , Venkatesh, Sudhakar K. , Ben‐Abraham, Ephraim I., Ehman, Richard L. , Venkatesh, Sudhakar K

Journal of Magnetic Resonance Imaging | February 5, 2014 | Volume: 41 | Issue: 2 | Pages: 369-375

10.1002/jmri.24572 Get It

Purpose To evaluate the feasibility of using three‐dimensional (3D) MR elastography (MRE) to determine the stiffness of the pancreas in healthy volunteers. Materials and Methods Twenty healthy volunteers underwent 1.5 Tesla MRE exams using an accelerated echo planar imaging (EPI) pulse sequence with low‐frequency vibrations (40 and 60 Hz). Stiffness was calculated with a 3D direct inversion algorithm. The mean shear stiffness in five pancreatic subregions (uncinate, head, neck, body, and tail) and the corresponding liver stiffness were calculated. The intrasubject coefficient of variation (CV) was calculated as a measure of the reproducibility for each volunteer. Results The mean shear stiffness (average of values obtained in different pancreatic subregions) was (1.15 ± 0.17) kPa at 40 Hz, and (2.09 ± 0.33) kPa at 60 Hz. The corresponding liver stiffness was higher than the pancreas stiffness at 40 Hz ([1.60 ± 0.21] kPa, mean pancreas‐to‐liver stiffness ratio: 0.72), but similar at 60Hz ([2.12 ± 0.23) kPa, mean ratio: 0.95). The mean intrasubject CV for each pancreatic subregion was lower at 40 Hz than 60 Hz ( P < 0.05 for all subregions, range: 11.9–15.7% at 40 Hz and 16.5–19.6% at 60 Hz). Conclusion The 3D pancreatic MRE can provide promising and reproducible stiffness measurements throughout the pancreas, with more consistent data acquired at 40 Hz. J. Magn. Reson. Imaging 2015;41:369–375. © 2013 Wiley Periodicals, Inc .