Back to Authors

Reisdorf, Ramona

Mayo Clinic

Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA.

Citations 4

Exploring Mechanisms of Calcific Tendonitis Using a Novel Turkey Model
Adam, Elameen, Bland, Joshua T. , Wan, Rou , Selim, Omar A., Tsukamoto, Ichiro, Reisdorf, Ramona L., Brosig, Maggie, Hooke, Alexander W. , Gingery, Anne , An, Kai‐Nan, Zhao, Chunfeng, Tsukamoto, Ichiro , Adam, Elameen A, Reisdorf, Ramona, Zhao, Chunfeng , Gingery, Anne , An, Kai‐Nan , Zhao, Chunfeng

Journal of Orthopaedic Research | January 21, 2026 | Volume: 44 | Issue: 1 | Pages: No page available

10.1002/jor.70136 Get It

ABSTRACT Calcific tendinopathy is a common musculoskeletal disorder marked by calcium deposition within tendons, often accompanied by pain, impaired mobility, and in severe cases, ossification. However, the mechanisms underlying tendon mineralization remain poorly understood. In contrast to pathological human calcification, turkeys naturally develop tendon mineralization during growth without signs of inflammation or ossification. This study had two phases: an observational phase to assess onset and progression of calcification, and an interventional phase to evaluate the role of mechanical loading. In the observational phase, flexor tendons were collected from turkeys aged 1–16 weeks in a serial sacrifice study and analyzed by Von Kossa staining and biomechanical testing. Calcification began at 7 weeks, localized within organized collagen matrices, progressed through Weeks 8–14, and peaked by 16 weeks. In the interventional phase, nine female turkeys were randomized at 4 weeks into a transection group ( n = 3), sham group ( n = 3), and control group ( n = 3). Transection at the muscle–tendon junction eliminated mechanical loading. At 16 weeks, tendons were analyzed by histology, quantitative RT‐PCR, ICP‐MS, and biomechanical testing. Transected tendons showed a near‐complete absence of mineralization, reduced expression of osteogenic markers (osteopontin, osteocalcin, Runx‐2), and significantly lower calcium, magnesium, and phosphorus levels. Biomechanical testing indicated reduced stress relaxation, stiffness, and Young's modulus in the transected group. Tendon calcification in turkeys functioned as a mechanically regulated, nonpathological process. The study established a relevant model for early tendon mineralization and offered a basis for developing load‐dependent therapies for human tendon disease.
Investigation of the Frictional Characteristics of a Manufactured Tendon Lubricant in Canine Peroneus Longus (PL) Tendons In Vitro
Nezameslami, Ahmadreza, Reisdorf, Ramona L., Zhao, Chunfeng , Amadio, Peter C. , Reisdorf, Ramona, Zhao, Chunfeng , Amadio, Peter C , Nezameslami, Ahmadreza, Larson, Dirk R.

Journal of Orthopaedic Research | December 15, 2025 | Volume: 44 | Issue: 1 | Pages: No page available

10.1002/jor.70093 Get It

ABSTRACT Tendon adhesion is a major complication following tendon reconstruction surgery in the hand. Previous studies showed that a combination of hyaluronic acid (HA) and gelatin, covalently bound to the tendon surface, can provide a durable gliding surface to reduce adhesions in animal models both in‐vitro and in‐vivo. We have developed a similar product using good manufacturing practice (GMP) standards, in preparation for use in humans. This study aimed to examine the frictional properties and elastic modulus of the Manufactured Tendon Lubricant (MTL) when applied to an extrasynovial canine peroneus longus (PL) tendon in‐vitro. Twenty PL tendons along with the 2nd and 5th digits from adult canine forepaws, were obtained (mean age: 12 months, weight: 35 kg) from animals sacrificed in Institutional Animal Care and Use Committee (IACUC) approved protocols. Tendons were treated either with the MTL or saline solution, as a control. Eight tendons from each group (MTL vs saline‐treated) underwent friction testing, using a previously described protocol, followed by indentation testing to assess tendon elastic modulus (a marker of successful crosslinking). Two tendons from each group were not tested and were sent for scanning electron microscopy (SEM). The MTL group had significantly ( p < 0.001) lower friction and gliding resistance as well as higher elastic modulus of the PL tendons, compared to the saline group. This study demonstrates that MTL provides lubricating effects and fixation to the tendon surface and may be suitable for human testing.
The effect of the number of strands and knot throws of core suture techniques on the mechanical properties of the repaired flexor tendon
Linden, Liliann R., Reisdorf, Ramona L., Selim, Omar , Berglund, Lawrence J., Zhao, Chunfeng , Selim, Omar , Reisdorf, Ramona, Berglund, Lawrence, Selim, Omar A

Journal of Orthopaedic Research | June 25, 2024 | Volume: 42 | Issue: 11 | Pages: 2382-2389

10.1002/jor.25916 Get It

Abstract Flexor tendon injury is a common hand trauma that requires surgical repair. The objective was to compare the repaired strength and gliding resistance with a varied number of repair strands and of square knots using a two‐strand‐overhand locking (TSOL) knot. First, isolated suture loops with different number of suture strands and number of closing knots were compared in mechanical strength and failure mode. Then, 90 flexor digitorum profundus (FDP) tendons from turkey digits were used for the tendon repair experiment. Both phases followed a similar 3 × 3 matrix comparing the knot type including TSOL+1SK (square knot), TSOL+2SK, and TSOL+3 SK and repair techniques including two‐, four‐, and six‐strand repairs techniques respectively. The repaired tendons were tested for tendon resistance against pulley (friction), maximum force, force at 2 mm displacement, stiffness, and failure mode. Increasing the number of strands and closing square knots increases the tensile strength and stiffness of flexor tendon repairs and isolated suture loops without a significant effect on tendon friction. An increase in the number of square knots have shown increased strength only in Pennington repair, which correlated with the increased number of knot unraveling, a weak knot failure model. Our data demonstrated that increasing the number of strands is effective for improving the overall strength of tendon repair. When a two‐strand repair is chosen, increasing knot number can improve repair strength. However, the number of knots appears not affecting repair strength in six‐strand repair technique.
Cell‐based tissue engineered flexor tendon allograft: A canine in vivo study
Lin, Subin, Reisdorf, Ramona L., Lu, Chun Kuan, An, Kai‐Nan, Moran, Steven L. , Amadio, Peter C. , Zhao, Chunfeng , Reisdorf, Ramona, Wang, Zhanwen , Amadio, Peter C , Zhao, Chunfeng , An, Kai‐Nan

Journal of Orthopaedic Research | April 19, 2024 | Volume: 42 | Issue: 9 | Pages: 1923-1932

10.1002/jor.25854 Get It

AbstractThis study aimed to compare the clinically established autologous extrasynovial tendon graft to a newly developed tissue‐engineered allograft (Eng‐allograft) in terms of functional outcomes following flexor tendon reconstruction in a canine model. The second and fifth flexor digitorum profundus (FDP) tendons from 16 dogs were transected and repaired in Zone II. After 6 weeks of cage activity, the repaired tendons were intentionally ruptured, creating a clinically relevant model for reconstruction. The re‐ruptured FDP tendons were then reconstructed using either the clinically standard autologous extrasynovial tendon graft or the Eng‐allograft, which had been revitalized with autologous bone marrow‐derived mesenchymal stem cells (BMSCs) and synovialized using carbodiimide derivatized synovial fluid (cd‐SYN). Following 12 weeks of postoperative rehabilitation, the functional outcomes of the surgical digits were evaluated. The Eng‐allograft group exhibited improved digital function, including lower digit work of flexion and reduced adhesion status, while maintaining similar tendon gliding resistance compared to the autograft group. However, the failure load of both the distal and proximal host/graft conjunctions in the Eng‐allograft group was significantly lower than that of the autograft group with higher graft rupture at the host−graft junction. In conclusion, the decellularized allogenic intrasynovial tendon, when revitalized BMSCs and synovialized with cd‐SYN, demonstrates positive effects on digital function improvement and adhesion reduction. However, the healing at both proximal and distal graft/host junctions is far lower than the autograft. Further research is needed to enhance the healing capacity of allograft conjunctions, aiming to achieve a comparable level of healing seen with autografts.