ABSTRACT Calcific tendinopathy is a common musculoskeletal disorder marked by calcium deposition within tendons, often accompanied by pain, impaired mobility, and in severe cases, ossification. However, the mechanisms underlying tendon mineralization remain poorly understood. In contrast to pathological human calcification, turkeys naturally develop tendon mineralization during growth without signs of inflammation or ossification. This study had two phases: an observational phase to assess onset and progression of calcification, and an interventional phase to evaluate the role of mechanical loading. In the observational phase, flexor tendons were collected from turkeys aged 1–16 weeks in a serial sacrifice study and analyzed by Von Kossa staining and biomechanical testing. Calcification began at 7 weeks, localized within organized collagen matrices, progressed through Weeks 8–14, and peaked by 16 weeks. In the interventional phase, nine female turkeys were randomized at 4 weeks into a transection group ( n = 3), sham group ( n = 3), and control group ( n = 3). Transection at the muscle–tendon junction eliminated mechanical loading. At 16 weeks, tendons were analyzed by histology, quantitative RT‐PCR, ICP‐MS, and biomechanical testing. Transected tendons showed a near‐complete absence of mineralization, reduced expression of osteogenic markers (osteopontin, osteocalcin, Runx‐2), and significantly lower calcium, magnesium, and phosphorus levels. Biomechanical testing indicated reduced stress relaxation, stiffness, and Young's modulus in the transected group. Tendon calcification in turkeys functioned as a mechanically regulated, nonpathological process. The study established a relevant model for early tendon mineralization and offered a basis for developing load‐dependent therapies for human tendon disease.
Purified Exosome Product Enhances Tendon-Bone Healing in a Rat Rotator Cuff Repair Model
Background: Tendon-bone healing after rotator cuff injury is, or remains, a clinical challenge. Purpose: To examine the role of intraoperative use of purified exosome products (PEPs) in the treatment of rotator cuff injuries and to assess the effect of PEP on supraspinatus tendon-bone healing after rotator cuff repair in a rat model. Study Design: Controlled laboratory study. Methods: This study used 120 Sprague-Dawley rats that underwent an acute supraspinatus tendon transection from the insertion, followed by repair using a single transosseous suture. They were divided into 3 groups: a control group that received only sutures, a TISSEEL group that used a commercially available fibrin sealant patch (TISSEEL) of approximately 0.5 cm 2 , and a PEP-TISSEEL group that used a similarly sized TISSEEL patch combined with PEP. Autopsies were performed at 1, 3, 6, and 8 weeks after surgery. Analyses were performed using molecular biological, biomechanical, and histological techniques. Results: At 6 weeks, the PEP-TISSEEL group achieved greater failure load (mean, 27.5 ± 5.3 N) than the control (mean, 16.4 ± 4.2 N; P = .012) and TISSEEL (mean, 23.4 ± 5.0 N; P = .041) groups, with superiority persisting at 12 weeks (27.2 ± 6.5 N vs 13.1 ± 2.6 N [ P = .002] for the control group and 21.1 ± 5.8 N [ P = .037] for the TISSEEL group). DigiGait showed earlier recovery of stride length and paw angle. Histology revealed organized collagen and reduced scarring, while molecular assays demonstrated early inflammatory modulation with subsequent upregulation of collagen type 1 or 3 and TGF-β, supporting accelerated tendon-bone healing. Conclusion: Intraoperative application of PEP-TISSEEL enhanced tendon-bone healing in a rat model by improving biomechanical strength, promoting enthesis-specific histological regeneration, and accelerating functional recovery as evidenced by gait analysis. Clinical Relevance: The intraoperative application of PEP combined with TISSEEL significantly enhances rotator cuff tendon healing by modulating early inflammation, promoting collagen synthesis, and improving biomechanical properties in a rat model. These findings suggest that PEP-based therapies could offer a promising adjunct in surgical repair, potentially reducing retear rates and improving functional outcomes in patients with rotator cuff injuries. Further clinical studies are warranted to translate these benefits into human applications.
The effect of cemented femoral component design and prophylactic wire placement against early periprosthetic femoral fracture in primary total hip arthroplasty
AimsPrevious studies have highlighted differences in the risk of periprosthetic fractures (PPFs) in patients undergoing total hip arthroplasty with either a cemented taper slip (TS) stem or a composite beam (CB) stem. This biomechanical study explored the occurrence of PPF around these stems, and the protective effect of adding a 16-gauge prophylactic calcar or diaphyseal wire to the TS stems to increase the resistance to torque as a potential way to prevent these fractures.MethodsA total of 21 TS stems (eight alone, six with calcar wiring, and seven with diaphyseal wiring placed 2 cm distal to the lesser trochanter) and seven CB stems were cemented into standard sawbones. The peak torque at failure was measured using a servohydraulic test machine, and the fracture location was recorded. An a priori power analysis determined that seven specimens per group were needed to detect a 30 Nm difference with 90% power, assuming a 14.8 Nm SD in peak torque between groups. Comparisons were performed using paired t-tests.ResultsCB stems exhibited a significantly higher mean peak torque at failure (205.3 Nm (SD 26.9)) than TS stems (159.5 Nm (SD 17.4); p = 0.012), calcar-wired TS (148.2 Nm (SD 38.6); p = 0.031), and diaphyseal-wired TS (164.9 Nm (SD 21.5); p = 0.027). This study did not demonstrate that wired-TS stems had a higher peak torque at failure than non-wired TS stems. Additionally, calcar wiring was not found to be stronger than diaphyseal wiring (p = 0.400). Four CB fractures occurred distal to the stem, whereas all TS fractures occurred at the mid-stem, simulating a Vancouver type B fracture. Interestingly, adding the diaphyseal wire shifted the fracture location more distally in four of the seven stems (p = 0.070).ConclusionIn this model, CB stems had greater resistance to torque than TS stems, which may explain the lower risk of PPF. Adding calcar or diaphyseal wires to the TS stems resulted in no significant change in peak torque to fracture. CB cemented stems should be considered in patients at high risk of PPF.Cite this article: Bone Joint J 2025;107-B(5 Supple A):32–37.
THE EFFECT OF CEMENTED FEMORAL COMPONENT DESIGN AND PROPHYLACTIC WIRE PLACEMENT AGAINST EARLY PERIPROSTHETIC FEMORAL FRACTURE IN PRIMARY TOTAL HIP ARTHROPLASTY: A BIOMECHANICAL STUDY
Previous studies have highlighted differences in the risk of periprosthetic fracture between tapered slip (TS) and composite beam (CB) stems. This biomechanical study explored periprosthetic fractures around these stems and the effect of adding a 16-gauge calcar or diaphyseal wire to TS stems on their resistance to torque.A power analysis determined a sample size of 7 specimens per group, assuming a standard deviation of 14.8 Nm in peak torque, to provide 90% power to detect a difference of at least 30 Nm between groups. Twenty-one TS stems (eight alone, six with calcar wiring, seven with diaphyseal wiring placed 2 cm distal to the lesser trochanter) and seven CB stems were cemented into standard Sawbones. A servo-hydraulic test machine applied a 1000 N load with a 1-degree rotation per second until failure. The peak torque at failure was measured, and the fracture location recorded. Comparisons were performed using two-sample t-tests.CB stems exhibited a significantly higher peak torque at failure (205.3 Nm) than TS stems (159.5 Nm, p=0.020). Calcar-wire-TS (148.2 Nm, p=0.036) and diaphyseal-wire-TS (164.9 Nm, p=0.036) were both weaker than CB stems. Wired-TS stems showed no significant difference from non-wired-TS stems. Additionally, the study could not conclude that calcar wiring is stronger than diaphyseal wiring. All TS fractures occurred at the mid-stem, simulating a B-type fracture, while the addition of the diaphyseal wire shifted the fracture location more distally in four of seven stems (p=0.0699).This biomechanical study supports the clinical evidence that CB stems have stronger resistance to torque than TS stems and may explain lower risk of periprosthetic fracture. The addition of calcar or diaphyseal wires to TS stems resulted in no significant changes in peak torque to fracture. In patients at high risk of periprosthetic fracture, CB cemented stems should be considered.
Ultrasound Shear Wave Elastography for Noninvasive Diagnosis of Acute Compartment Syndrome Using a Novel In Vivo Turkey Model
ABSTRACT Introduction Acute Compartment Syndrome (ACS) is a severe trauma caused by elevated intra-muscle-compartment pressure (ICP). The current standard method for diagnosis is to insert a needle into the muscle sterilely under anesthesia. However, to secure the environment is sometimes not easy and leads to delays in diagnosis. Recently, we have focused on shear wave ultrasound elastography (SWE) as an alternative, which can be done concisely in unclean environment and without anesthesia. We would like to report the usefulness of SWE for ACS diagnosis using 2-pedal walking turkey model recently developed in our lab. Materials and Methods A total of 32 1-year-old Bourbon turkeys were used. 5% solution of chicken albumin was infused continuously into the tibialis cranialis (TC) muscle using IV pump. The ICP was increased stepwise from 0 to 50 mmHg. During the rising of ICP, the correlation between values of SWE (kPa) and ICP (mmHg) was measured. After the ICP reached 50 mmHg, half of the turkeys were maintained at this pressure for 2 hours and the rest for 6 hours. After infusion, a fasciotomy was performed on the half turkey. Half of the turkeys were euthanized after 2 weeks and the rest after 6 weeks. SWE of TC muscle and walking gait data on turkeys using a portable walkway system were measured weekly until euthanasia. At euthanasia, isometric tetanic muscle force (ITF) tests to TC muscle and histological evaluations were performed. Results SWE value (kPa) was highly significantly correlated to the actual ICP (mmHg) (R2 = 0.91). Stance of ACS side leg were significantly extended, and swing of the control side shortened from the second to the third week after ACS in the 6 hours infusion-no-fasciotomy group (P < 0.05*). ITF was significantly reduced mainly in the 6 hours infusion group (P < 0.05*). Histological evaluation revealed that in the 6 hours infusion and 6 weeks survival group, both the muscle fiber and intercellular distances were significantly expanded (P < 0.05). Conclusion SWE seems to be a substitute measure of ICP in diagnosing ACS. With regard to our in vivo ACS model using turkey, survival at 50 mmHg ICP for 6 hours and 6 weeks post ACS would be an appropriate situation.