The force within a muscle may be assessed using intramuscular pressure measurements (IMP). However, a limiting factor in implementing this technology in the clinic is the observed variability of IMP measurements. The variability may be due in part to the flow of interstitial fluid. The objective of this study was to develop a technique for tracking interstitial fluid flow during muscle lengthening using fluorescent microspheres. Additionally, the effect of microsphere diameter on dispersion was evaluated. Fluorescent microspheres were injected into the rat tibialis anterior (TA) either before (right limb) or after (left limb) lengthening to 10% strain (n = 5). To help discriminate the effects of microsphere size, 10 µl of microspheres (0.25% by volume) were injected simultaneously: 0.1 µm in sky blue and 0.2 µm in yellow green. Once frozen, 20 µm muscle cross‐sections were stained and imaged using confocal microscopy to evaluate the microsphere's axial dispersion as a percent of muscle length. The microsphere dispersion was normalized to the muscle length. The fluorescent microspheres flowed with the interstitial fluid and did not penetrate the muscle fiber. There was significantly greater microsphere dispersion with passive strain (p‐value > 0.01) for lengthened samples (31±7%) compared to static samples (17±9%). Dispersion did not differ for the two bead sizes. In conclusion, this illustrates the microspheres track the interstitial fluid and passive lengthening results in additional dispersion. Supported by NIH under award number R01HD31476 and T32HL105355.
Validation of a dynamic joint contracture measuring device in a live rabbit model of arthrofibrosis
Abstract Quantitative evaluation of passive tension in a muscle is important in tendon transfer surgeries, however, currently appropriate intraoperative measurement techniques are lacking. Objective : Intramuscular pressure (IMP) is explored as an application to access force. Approach : The tibialis anterior (TA) in New Zealand white rabbits ( n = 9) was used to test the hypothesis of a strong correlation between the IMP, muscle force, and length. This study also helped to develop intraoperative techniques for future human studies evaluating various insertion techniques (parallel versus perpendicular). Main results : The Pearson correlation between IMP and force for all trials was 0.74 ± 0.30. Separating out the parallel insertion from the perpendicular insertion revealed a significantly higher correlation for parallel, 0.91 ± 0.13 versus 0.56 ± 0.32. Significance : These data indicate IMP sensors can be used to assess force in a single muscle and the parallel insertion method should be used. New findings • What is the central question of this study? Successful outcomes of tendon and muscle transfers depend on proper muscle tension. A near linear relationship has been seen between muscle force and intramuscular pressure. This study aims to develop an intraoperative technique for assessing passive muscle tension using intramuscular pressure. • What is the main finding and its importance? The findings from this study reveal a high correlation between pressure and passive tension in a single muscle. The techniques developed in this study will allow the translation to a human model. The work will help to improve surgical outcomes and aim to retain muscle strength in the patient following procedures such as tendon and muscle transfers.
Analysis of fluid movement in skeletal muscle using fluorescent microspheres
ABSTRACTIntroductionRegional variability in interstitial fluid pressure confounds use of intramuscular pressure measurement to assess muscle force. It is hypothesized that interstitial flow is dependent on intramuscular pressure. The goal of this study was to assess the feasibility of using fluorescent microspheres to evaluate movement of interstitial fluid in skeletal muscle.MethodsTwo diameters of fluorescent microspheres were injected into the rat tibialis anterior during both static (n = 6) and passively lengthened (10% strain) experimental conditions (n = 6). Microsphere dispersion was evaluated using confocal imaging of transverse muscle sections.ResultsFluorescent microspheres tracked interstitial fluid while not penetrating the muscle fiber. When compared with the static condition, significantly greater dispersion (P = 0.003) was seen with passively lengthened conditions (17 ± 9% vs. 31 ± 7%, respectively). Dispersion did not differ for the 2 microsphere sizes (P = 0.811).ConclusionsFluorescent microspheres track movement of interstitial fluid, and dispersion is dependent on passive lengthening. Muscle Nerve 54: 444–450, 2016