Back to Authors

Holmes, David R.

https://orcid.org/0000-0002-0037-0373

Mayo Clinic

Mayo Clinic

Citations 350

Regional Variation in the Management and Outcomes of Acute Myocardial Infarction With Cardiogenic Shock in the United States
Vallabhajosyula, Saraschandra , Patlolla, Sri Harsha , Prasad, Abhiram , Bell, Malcolm R. , Jaffe, Allan S. , Rihal, Charanjit S. , Holmes, David R. , Barsness, Gregory W. , Dunlay, Shannon M. , Vallabhajosyula, Saraschandra , Harsha Patlolla, Sri , Prasad, Abhiram , Jaffe, Allan S. , Gersh, Bernard J. , Rihal, Charanjit S.

Circulation: Heart Failure | February 14, 2020 | Volume: 13 | Issue: 2 | Pages: No page available

10.1161/circheartfailure.119.006661 Get It

Background: There are few studies evaluating regional disparities in the care of acute myocardial infarction-cardiogenic shock (AMI-CS). Methods and Results: Using the National Inpatient Sample from 2000 to 2016, we identified adults with a primary diagnosis of AMI and concomitant CS admitted to the United States census regions of Northeast, Midwest, South, and West. Interhospital transfers were excluded. End points of interest included in-hospital mortality, use of coronary angiography, percutaneous coronary intervention, mechanical circulatory support, hospitalization costs, length of stay, and discharge disposition. Multivariable regression was used to adjust for potential confounding. Of the 402 825 AMI-CS admissions, 16.8%, 22.5%, 39.3%, and 21.4% were admitted to the Northeast, Midwest, South, and West, respectively. Higher rates of ST-elevation AMI-CS were noted in the Midwest and West. Admissions to the Northeast were on average characterized by a higher frequency of whites, Medicare beneficiaries, and lower rates of cardiac arrest. Admissions to the Northeast were less likely to receive coronary angiography, percutaneous coronary intervention, and mechanical circulatory support, despite the highest rates of extracorporeal membrane oxygenation use. Compared with the Northeast, in-hospital mortality was lower in the Midwest (adjusted odds ratio [aOR], 0.96 [95% CI, 0.93–0.98]; P <0.001) and West (aOR, 0.96 [95% CI, 0.94–0.98]; P =0.001) but higher in the South (aOR, 1.04 [95% CI, 1.01–1.06]; P =0.002). The Midwest (aOR, 1.68 [95% CI, 1.62–1.74]; P <0.001), South (aOR, 1.86 [95% CI, 1.80–1.92]; P <0.001), and West (aOR, 1.93 [95% CI, 1.86–2.00]; P <0.001) had higher discharges to home. Conclusions: There remain significant regional disparities in the management and outcomes of AMI-CS.
Stent-Only Versus Adjunctive Balloon Angioplasty Approach for Saphenous Vein Graft Percutaneous Coronary Intervention
Latif, Faisal , Uyeda, Lauren , Edson, Robert , Bhatt, Deepak L. , Goldman, Steven , Holmes, David R. , Shunk, Kendrick , Aggarwal, Kul, Bolad, Islam, Ziada, Khaled M. , McFalls, Edward O. , Irimpen, Anand, Truong, Huu Tam, Kinlay, Scott , Velagaleti, Raghava S. , Rangan, Bavana V. , Mavromatis, Kreton , Shih, Mei-Chiung , Ziada, Khaled , Bhatt, Deepak L , Rao, Sunil V. , Uretsky, Barry F. , Papademetriou, Vasilios , Banerjee, Subhash , Brilakis, Emmanouil S.

Circulation: Cardiovascular Interventions | February 5, 2020 | Volume: 13 | Issue: 2 | Pages: No page available

10.1161/circinterventions.119.008494 Get It

Background: Direct stenting without pre-dilation or post-dilation has been advocated for saphenous vein graft percutaneous coronary intervention to decrease the incidence of distal embolization, periprocedural myocardial infarction, and target lesion revascularization. Methods: We performed a post hoc analysis of patients enrolled in the DIVA (Drug-Eluting Stents Versus Bare Metal Stents in Saphenous Vein Graft Angioplasty; NCT 01121224) prospective, double-blind, randomized controlled trial. Patients were stratified into stent-only and balloon-stent groups. Primary end point was 12-month incidence of target vessel failure (defined as the composite of cardiac death, target vessel myocardial infarction, or target vessel revascularization). Secondary end points included all-cause death, stent thrombosis, myocardial infarction, and target lesion revascularization during follow-up. Results: Of the 575 patients included in this substudy, 185 (32%) patients underwent stent-only percutaneous coronary intervention. Patients in the stent-only versus balloon-stent group had similar baseline characteristics and similar incidence of target vessel failure at 12-months (15% versus 19%; hazard ratio, 1.34 [95% CI, 0.86–2.08]; P =0.19). During long-term follow-up (median of 2.7 years), the incidence of definite stent thrombosis (1% versus 5%; hazard ratio, 9.20 [95% CI, 1.23–68.92]; P =0.0085), the composite of definite or probable stent thrombosis (5% versus 11%; hazard ratio, 2.52 [95% CI, 1.23–5.18]; P =0.009), and target vessel myocardial infarction (8% versus 14%; hazard ratio, 1.92 [95% CI, 1.08–3.40]; P =0.023) was lower in the stent-only group. Multivariable analysis showed that a higher number of years since coronary artery bypass grafting and >1 target saphenous vein graft lesions were associated with increased target vessel failure during entire follow-up, while preintervention Thrombolysis in Myocardial Infarction-3 flow was protective. Conclusions: In patients undergoing percutaneous coronary intervention of de novo saphenous vein graft lesions, there was no difference in target vessel failure at 12 months and long-term follow-up in the stent-only versus the balloon-stent group; however, the incidence of stent thrombosis was lower in the stent-only group, as was target vessel myocardial infarction. Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT 01121224.
P339 Gradient adjusted cardiac power index does not improve prediction of survival post transcatheter aortic valve replacement compared to cardiac power index alone
Mookadam, Farouk , Venepally, Nithin R. , Wang, P, Khetarpal, Banveet Kaur , Sweeney, Joseph C. , Eleid, M, Pollak, Peter , Fortuin, F. David , Holmes, David R. , Agasthi, Pradyumna , Mookadam, Farouk , Sweeney, J, Arsanjani, Reza

European Heart Journal - Cardiovascular Imaging | January 17, 2020 | Volume: 21 | Issue: Supplement_1 | Pages: No page available

10.1093/ehjci/jez319.192 Get It

Abstract Funding Acknowledgements None Background Cardiac Power Index (CPI) is an integrative hemodynamic measure of cardiac pumping capability and is the product of the simultaneously measured mean arterial pressure (MAP) and cardiac output (CO). In patients with aortic stenosis (AS), MAP is not reflective of mean systolic left ventricular (LV) pressure due to the transvalvular gradient. Non-invasive assessment of mean systolic LV pressure is challenging in severe aortic stenosis. CPI assessed using systemic MAP was previously shown to predict survival post transcatheter aortic valve replacement (TAVR). Purpose We evaluated the utility of a gradient adjusted CPI in predicting survival post TAVR compared to CPI alone Methods A retrospective study was performed including patients undergoing TAVR with 1 year follow-up. Baseline demographics, clinical, and echocardiographic data were abstracted from a cohort of 1,011 patients. CPI was calculated, (CO x MAP)/ (451 x BSA) Watts/m2. Gradient adjusted CPI was calculated using an augmented MAP i) adding aortic valve mean gradient(AVMG) to systolic blood pressure (CPI1); ii) adding aortic valve maximal instantaneous gradient to systolic blood pressure (CPI2) and iii) adding AVMG to MAP (CPI3). Patient survival score was calculated using a step up technique to identify the cut off value for CPI and gradient adjusted CPI to identify, where the maximum difference in mortality occurred. Multivariate cox-regression analysis was performed to adjust for baseline covariates. Receiver operator curves(ROC) for CPI and gradient adjusted CPI were calculated to predict survival post TAVR. Results The mortality rate at 1 yr was 16%. Mean age and AVMG of survivors was 81 +/- 9 yrs and 43 +/-14 mmHg vs 80 +/-9 yrs and 42 +/- 13 mmHg in the deceased group. Proportion of female patients was similar in both groups (p = 0.7). Patients in the deceased group at baseline had a higher prevalence of chronic lung disease, atrial fibrillation, heart failure within 2-weeks of procedure, higher STS-PROM score, lower serum albumin level, higher prevalence of moderate to severe tricuspid regurgitation, higher right ventricular systolic pressure and higher prevalence of dialysis. Both CPI and gradient adjusted CPI were independently associated with survival at 1 year. The area under ROC for CP, CP1, CP2 and CP3 were 0.67 (95% confidence interval [CI] 0.62 - 0.72), 0.65 (95% CI 0.60 – 0.70), 0.66 (95% CI 0.61 – 0.71) and 0.63 (95% CI 0.58 – 0.68) respectively. Conclusion Gradient adjusted CPI did not improve accuracy of predicting post TAVR survival at 1 year compared to CPI alone. Abstract P339 Figure. Area under ROC
Incidence, Temporal Trends, and Associated Outcomes of Vascular and Bleeding Complications in Patients Undergoing Transfemoral Transcatheter Aortic Valve Replacement
Sherwood, Matthew W. , Xiang, Katelyn, Li, Zhuokai , Vemulapalli, Sreekanth , Vora, Amit N. , Harrison, J. Kevin , Thourani, Vinod H. , Holmes, David R. , Kirtane, Ajay J. , Pineda, Andrés M. , Douglas, Pamela S. , Douglas, Pamela S , Matsouaka, Roland , Fanaroff, Alexander C. , Peterson, Eric D. , Rao, Sunil V.

Circulation: Cardiovascular Interventions | January 15, 2020 | Volume: 13 | Issue: 1 | Pages: No page available

10.1161/circinterventions.119.008227 Get It

Background: Vascular and bleeding complications were commonly reported in transcatheter aortic valve replacement clinical trials. Little is known about complication rates in contemporary US clinical practice or clinical outcomes associated with these complications. Methods: In the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry, we evaluated patients undergoing transcatheter aortic valve replacement from November 1, 2011 to June 30, 2016. The primary outcomes were in-hospital vascular complications and bleeding events. Secondary outcomes included all-cause mortality, stroke, and rehospitalization at 1 year. P values for trends were calculated for rates over time, and multivariable logistic regression was used to determine the association between vascular/bleeding complications and in-hospital clinical outcomes. Results: Overall, 34 893 patients undergoing transcatheter aortic valve replacement at 445 hospitals were analyzed. Of these, 9.3% (n=3257) experienced a vascular complication while 7.6% (n=2651) had an in-hospital bleeding event. Rates of both vascular complications and bleeding events decreased over time ( P value for trend test <0.0001); however, there was significant variation in rates across hospital sites (adjusted median rate, 11.4%; IQR, 8.9–14.5). Vascular complications were independently associated with 30-day death (adjusted HR, 2.23 [95% CI, 1.80–2.77]) and death (adjusted HR, 1.17 [95% CI, 1.05–1.30]) and rehospitalization (adjusted HR, 1.14 [95% CI, 1.07–1.22]) at 1 year. Bleeding events were also associated with 30-day death (adjusted HR, 3.71 [95% CI, 2.94–4.69]), and with death (adjusted HR, 1.39 [95% CI, 1.23–1.56]) and hospital readmission (adjusted HR, 1.19 [95% CI, 1.11–1.27]) at 1 year. Conclusions: In patients undergoing transcatheter aortic valve replacement in the US, vascular complications and in-hospital bleeding events were common, but rates have declined over time with significant variation in complication rates across hospital sites. Vascular and bleeding complications are both associated with worse short- and long-term clinical outcomes including all-cause mortality. Further innovation to reduce sheath sizes and optimize antithrombotic therapy is necessary to reduce the incidence of these detrimental complications.
Transcatheter closure of coronary artery fistula: A 21‐year experience
El‐Sabawi, Bassim , Al‐Hijji, Mohammed , Eleid, Mackram F. , Cabalka, Allison K. , Ammash, Naser M., Dearani, Joseph A. , Bjarnason, Haraldur , Holmes, David R. , Rihal, Charanjit S. , Al-Hijji, Mohammed A , Cabalka, Allison , Bjarnason, Haraldur , Dearani, Joseph A. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | January 10, 2020 | Volume: 96 | Issue: 2 | Pages: 311-319

10.1002/ccd.28721 Get It

AbstractObjectivesTo evaluate the outcomes of transcatheter coronary artery fistula (CAF) closure and to identify anatomic/procedural factors that may impact outcomes.BackgroundDue to the rarity of CAF, reported experience with transcatheter closure remains limited and anatomic and procedural factors that may lead to unsuccessful closure, complications, or recanalization of CAF are unclear.MethodsAll patients who underwent transcatheter CAF closure at Mayo Clinic from 1997 to 2018 were retrospectively reviewed. CAF anatomic characteristics, procedural techniques, and clinical/angiographic outcomes were assessed.ResultsA total of 45 patients underwent transcatheter closure of 56 CAFs. The most commonly used devices were embolization coils in 40 (71.4%) CAFs, vascular occluders in 10 (17.8%), or covered stent in 2 (3.6%). Acute procedural success with no or trivial residual flow occurred in 50 (89.3%) CAFs. Residual flow was small in three (5.4%) and large in three (5.4%). Eight (17.8%) patients had complications, including device migration in three, intracranial hemorrhage from anticoagulation in one, and myocardial infarction (MI) in four. MI was a result of covered stent thrombosis or stagnation of flow after closure of large distal CAF. Twenty‐two patients with 27 CAFs had follow‐up angiography after successful index procedure at median time of 423 (IQ 97‐1348) days. Of these, 23 (85.2%) had no/trace flow and 4 had large flow from recanalization.ConclusionsTranscatheter CAF closure is associated with a favorable acute procedural success and complication rate in selected patients. Procedural success and risk for complication are highly dependent on CAF anatomy and closure technique.
Treatment after TAVR — Discordance and Clinical Implications
Nishimura, Rick A., Holmes, David R.

New England Journal of Medicine | January 8, 2020 | Volume: 382 | Issue: 2 | Pages: 193-194

10.1056/nejme1915930 Get It

Recurrent pulmonary vein stenosis after successful intervention: Prognosis and management of restenosis
Fender, Erin A. , Widmer, R. Jay , Mahowald, Madeline , Hodge, David O. , Packer, Douglas L. , Holmes, David R. , Mahowald, Madeline K , Widmer, Robert Jay

Catheterization and Cardiovascular Interventions | December 19, 2019 | Volume: 95 | Issue: 5 | Pages: 954-958

10.1002/ccd.28645 Get It

Abstract Objectives The aim of this study was to describe management of recurrent pulmonary vein stenosis (PVS) and determine if stenting is superior to balloon angioplasty (BA) in preventing subsequent restenosis. Background PVS is a serious complication of atrial fibrillation ablation. BA and stenting are effective therapies; however, restenosis frequently occurs. Here we report management of recurrent stenosis. Methods This was a prospective observational study performed from 2000 to 2014. Results One hundred and thirteen patients with severe PVS underwent intervention in 88 veins treated with BA and 81 treated with stenting. Forty‐two patients experienced restenosis. Restenosis was more common in veins treated with BA (RRR 53% [95% CI 32–70%, p = .008]). A second intervention was performed in 41 patients. In the 34 vessels treated with initial BA, 24 were treated for restenosis with a stent and 10 were treated with a second BA. The recurrence rate was 46% in those treated with BA followed by stenting and 50% in those treated with two BA procedures. In the 22 veins treated with initial stenting, 9 were treated with another stent and 13 were treated with BA. The recurrence rate was 44% in those treated with a second stent and 46% for those treated with a stent followed by BA. The risk of a third stenosis was the same among all groups (Analysis of variance [ANOVA] p = .99). Limited sample size precluded analysis of outcome by stent size. Conclusions Restenosis occurred in 44% of patients overall. Management is challenging; stenting does not appear to be superior to BA.
Extracorporeal Membrane Oxygenation Use in Acute Myocardial Infarction in the United States, 2000 to 2014
Vallabhajosyula, Saraschandra , Prasad, Abhiram , Bell, Malcolm R. , Sandhu, Gurpreet S. , Eleid, Mackram F. , Schears, Gregory J. , Stulak, John M., Jaffe, Allan S. , Holmes, David R. , Rihal, Charanjit S. , Barsness, Gregory W. , Dunlay, Shannon M. , Vallabhajosyula, Saraschandra , Prasad, Abhiram , Singh, Mandeep , Gersh, Bernard J. , Jaffe, Allan S. , Rihal, Charanjit S.

Circulation: Heart Failure | December 12, 2019 | Volume: 12 | Issue: 12 | Pages: No page available

10.1161/circheartfailure.119.005929 Get It

Background: Extracorporeal membrane oxygenation (ECMO) is increasingly used in acute myocardial infarction (AMI); however, there are limited large-scale national data. Methods: Using the National Inpatient Sample database from 2000 to 2014, a retrospective cohort of AMI utilizing ECMO was identified. Use of percutaneous coronary intervention, intra-aortic balloon pump, and percutaneous left ventricular assist device (LVAD) was also identified in this population. Outcomes of interest included temporal trends in utilization of ECMO alone and with concomitant procedures (percutaneous coronary intervention, intra-aortic balloon pump, and percutaneous LVAD), in-hospital mortality, and resource utilization. Results: In ≈9 million AMI admissions, ECMO was used in 2962 (<0.01%) and implanted a median of 1 day after admission. ECMO was used in 0.5% and 0.3% AMI admissions complicated by cardiogenic shock and cardiac arrest, respectively. ECMO was used more commonly in admissions that were younger, nonwhite, and with less comorbidity. ECMO use was 11× higher in 2014 as compared with 2000 (odds ratio, 11.37 [95% CI, 7.20–17.97]). Same-day percutaneous coronary intervention was performed in 23.1%; intra-aortic balloon pump/percutaneous LVAD was used in 57.9%, of which 30.3% were placed concomitantly. In-hospital mortality with ECMO was 59.2% overall but decreased from 100% (2000) to 45.1% (2014). Durable LVAD and cardiac transplantation were performed in 11.7% as an exit strategy. Of the hospital survivors, 40.8% were discharged to skilled nursing facilities. Older age, male sex, nonwhite race, and lower socioeconomic status were independently associated with higher in-hospital mortality with ECMO use. Conclusions: In AMI admissions, a steady increase was noted in the utilization of ECMO alone and with concomitant procedures (percutaneous coronary intervention, intra-aortic balloon pump, and percutaneous LVAD). In-hospital mortality remained high in AMI admissions treated with ECMO.
Intravascular ultrasound, optical coherence tomography, and fractional flow reserve use in acute myocardial infarction
Vallabhajosyula, Saraschandra , Hajj, Stephanie C. El , Bell, Malcolm R. , Prasad, Abhiram , Rihal, Charanjit S. , Holmes, David R. , Barsness, Gregory W. , El Hajj, Stephanie C, Holmes, David R , Vallabhajosyula, Saraschandra , Prasad, Abhiram , Hajj, Stephanie C. El , Lerman, Amir , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | November 14, 2019 | Volume: 96 | Issue: 1 | Pages: No page available

10.1002/ccd.28543 Get It

AbstractBackgroundThere are limited data on the use of intravascular ultrasound (IVUS), optical coherence tomography (OCT), and fractional flow reserve (FFR) during acute myocardial infarction (AMI).ObjectivesTo assess the temporal trends of IVUS, OCT, and FFR use in AMI.MethodsA retrospective cohort study from the National Inpatient Sample (2004–2014) was designed to include AMI admissions that received coronary angiography. Administrative codes were used to identify percutaneous coronary intervention (PCI), IVUS, OCT, and FFR. Outcomes included temporal trends, inhospital mortality and resource utilization stratified by IVUS, OCT, or FFR use.ResultsIn 4,419,973 AMI admissions, IVUS, OCT, and FFR were used in 2.6%, 0.1%, and 0.6%, respectively. There was a 22‐fold, 118‐fold, and 33‐fold adjusted increase in IVUS, OCT, and FFR use, respectively, in 2014 compared to the first year of use. Non‐ST‐elevation AMI presentation, male sex, private insurance coverage, admission to a large urban hospital, and absence of cardiac arrest and cardiogenic shock were associated with higher IVUS, OCT, or FFR use. PCI was performed in 83.2% of the IVUS, OCT, or FFR cohort compared to 64.2% of the control group (p < .001). The cohort with IVUS/OCT/FFR use had lower inhospital mortality (adjusted odds ratio 0.53 [95% confidence interval 0.50–0.56]), more frequent discharges to home (83.7% vs. 76.8%), shorter hospital stays (4.3 ± 4.4 vs. 5.0 ± 5.5 days) and higher hospitalization costs ($90,683 ± 74,093 vs. $74,671 ± 75,841).ConclusionsIn AMI, the use of IVUS, OCT, and FFR has increased during 2004–2014. Significant patient and hospital‐level disparities exist in the use of these technologies.
Automatic detection of calcium phosphate deposit plugs at the terminal ends of kidney tubules
Fernandez, K. A. , Korinek, Mark, Camp, Jon J. , Holmes, David R. , Fernandez, Katrina, Camp, Jon, Lieske, John, Fernandez, K A , Lieske, John C.

Healthcare Technology Letters | October 11, 2019 | Volume: 6 | Issue: 6 | Pages: 271-274

10.1049/htl.2019.0086 Get It

Kidney stones are a common urologic condition with a high amount of recurrence. Recurrence depends on a multitude of factors the incidence of precursors to kidney stones, plugs, and plaques. One method of characterising the stone precursors is endoscopic assessment, though it is manual and time‐consuming. Deep learning has become a popular technique for semantic segmentation because of the high accuracy that has been demonstrated. The present Letter examined the efficacy of deep learning to segment the renal papilla, plaque, and plugs. A U‐Net model with ResNet‐34 encoder was tested; the Letter examined dropout (to avoid overtraining) and two different loss functions (to address the class imbalance problem. The models were then trained in 1666 images and tested on 185 images. The Jaccard‐cross‐entropy loss function was more effective than the focal loss function. The model with the dropout rate 0.4 was found to be more effective due to its generalisability. The model was largely successful at delineating the papilla. The model was able to correctly detect the plaques and plugs; however, small plaques were challenging. Deep learning was found to be applicable for segmentation of an endoscopic image for the papilla, plaque, and plug, with room for improvement.