Photon-Counting Detector CT: Key Points Radiologists Should Know
Esquivel, Andrea , Ferrero, Andrea , Mileto, Achille , Baffour, Francis , Horst, Kelly K. , Rajiah, Prabhakar , Inoue, Akitoshi , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Horst, Kelly , Rajiah, Prabhakar , McCollough, Cynthia H , Fletcher, Joel G , Leng, Shuai , Baffour, Francis I , Inoue, Akitoshi

Korean Journal of Radiology | August 10, 2022 | Volume: 23 | Issue: 9 | Pages: 854

10.3348/kjr.2022.0377 Get It

Dedicated convolutional neural network for noise reduction in ultra-high-resolution photon-counting detector computed tomography
Huber, Nathan R. , Ferrero, Andrea , Rajendran, Kishore , Glazebrook, Katrina N. , Yu, Lifeng , Baffour, Francis , Diehn, Felix E. , Inoue, Akitoshi , Rajendran, Kishore , Huber, Nathan Robert , Fletcher, Joel G. , Yu, Lifeng , Leng, Shuai , McCollough, Cynthia H.

Physics in Medicine & Biology | August 9, 2022 | Volume: 67 | Issue: 17 | Pages: 175014

10.1088/1361-6560/ac8866 Get It

Abstract Objective. To develop a convolutional neural network (CNN) noise reduction technique for ultra-high-resolution photon-counting detector computed tomography (UHR-PCD-CT) that can be efficiently implemented using only clinically available reconstructed images. The developed technique was demonstrated for skeletal survey, lung screening, and head angiography (CTA). Approach . There were 39 participants enrolled in this study, each received a UHR-PCD and an energy integrating detector (EID) CT scan. The developed CNN noise reduction technique uses image-based noise insertion and UHR-PCD-CT images to train a U-Net via supervised learning. For each application, 13 patient scans were reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) and allocated into training, validation, and testing datasets (9:1:3). The subtraction of FBP and IR images resulted in approximately noise-only images. The 5-slice average of IR produced a thick reference image. The CNN training input consisted of thick reference images with reinsertion of spatially decoupled noise-only images. The training target consisted of the corresponding thick reference images without noise insertion. Performance was evaluated based on difference images, line profiles, noise measurements, nonlinear perturbation assessment, and radiologist visual assessment. UHR-PCD-CT images were compared with EID images (clinical standard). Main results. Up to 89% noise reduction was achieved using the proposed CNN. Nonlinear perturbation assessment indicated reasonable retention of 1 mm radius and 1000 HU contrast signals (>80% for skeletal survey and head CTA, >50% for lung screening). A contour plot indicated reduced retention for small-radius and low contrast perturbations. Radiologists preferred CNN over IR for UHR-PCD-CT noise reduction. Additionally, UHR-PCD-CT with CNN was preferred over standard resolution EID-CT images. Significance. CT images reconstructed with very sharp kernels and/or thin sections suffer from increased image noise. Deep learning noise reduction can be used to offset noise level and increase utility of UHR-PCD-CT images.
Sarcopenia identified by computed tomography (CT) imaging using a machine learning–based convolutional neural network (CNN) algorithm impacts survival in patients with newly diagnosed multiple myeloma (NDMM).
Nandakumar, Bharat , Abdallah, Nadine , Kumar, Shaji , Kapoor, Prashant , Lacy, Martha Q. , Hayman, Suzanne R. , Warsame, Rahma , Kourelis, Taxiarchis , Korfiatis, Panagiotis , Klug, Jason R., Dispenzieri, Angela , Dingli, David , Go, Ronald S. , Buadi, Francis K. , Leung, Nelson , Muchtar, Eli , Rajkumar, S. Vincent , Gertz, Morie A. , Baffour, Francis , Gonsalves, Wilson I.

Journal of Clinical Oncology | June 6, 2022 | Volume: 40 | Issue: 16_suppl | Pages: 110-110

10.1200/jco.2022.40.16_suppl.110 Get It

110 Background: Sarcopenia or a loss of muscle mass increases with aging and is associated with increased overall mortality in patients with cancer. Recent advances in machine learning–based CNN algorithms have allowed for the rapid processing of digital images to produce image classifications of body composition. Since incidence of MM is highly associated with aging, we sought to determine if the presence of sarcopenia, as determined by utilizing this machine learning–based CNN algorithm on CT images, had prognostic value in patients with NDMM. Methods: We identified all patients with NDMM from January 2003 to July 2019 who had a standard-dose CT scan that included the L3 vertebral level performed within 6 months of diagnosis. Using a machine learning–based CNN-algorithm, abdominal CT images were analyzed to measure muscle area. These measurements were normalized by dividing the area values by the height of the patient squared (m2) to obtain skeletal muscle index (SMI) values. Patients were categorized as sarcopenic according to international gender-specific consensus cutoffs for SMI (male: < 55 cm2/m2 and female: < 39 cm2/m2). Patients with the following FISH cytogenetics were considered high risk (HR): t(4;14), t(14;16), t(14;20), and deletion 17p/monosomy 17 whereas the remainder were standard risk (SR). Survival analysis was performed using the Kaplan-Meier method and compared via the log-rank method. Results: The study cohort consisted of 344 patients. 68 (20%) were categorized as HR based on FISH cytogenetics.187 (54%) patients were sarcopenic based on their peri-diagnosis standard-dose CT scan. Sarcopenic patients were more likely to have ISS-3 disease (45% vs. 30%; p =.023), be male (73% vs. 48%; p <.001), and be ≥ age 75 (27% vs. 14%; p =.002) compared to non-sarcopenic patients. The median OS for patients with HR FISH and ISS 2 / 3 disease was 40 months and 57 months respectively compared to 90 months and 119 months for those with SR FISH and ISS-1 disease respectively (FISH: p <.004; ISS: p <.001). The median OS for sarcopenic patients was 44 months compared to 90 months for those not sarcopenic (p <.001). The time to next therapy (TTNT) for sarcopenic patients was 39 months compared to 45 months for those not sarcopenic (p =.05). In a multivariable model, the presence of sarcopenia (HR 1.64, 95% CI, 1.05–2.56; p =.03) retained significance in the presence of HR FISH, ISS 2 / 3 disease, and age ≥ 75. Conclusions: Gender-specific sarcopenia identified by a machine learning–based CNN algorithm significantly affects OS in patients with NDMM and is independent of age, ISS stage, and cytogenetic status. Future studies utilizing this machine learning–based methodology of assessing sarcopenia in larger prospective clinical trials are required to validate these findings.
An interactive eye‐tracking system for measuring radiologists' visual fixations in volumetric CT images: Implementation and initial eye‐tracking accuracy validation
Gong, Hao , Hsieh, Scott S. , Holmes, David R. , Cook, David A. , Bartlett, David J. , Baffour, Francis , Takahashi, Hiroaki , Yu, Lifeng , Inoue, Akitoshi , Baffour, Francis I , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H. , Fletcher, Joel G. , Takahashi, Hiroaki

Medical Physics | September 17, 2021 | Volume: 48 | Issue: 11 | Pages: 6710-6723

10.1002/mp.15219 Get It

AbstractPurposeEye‐tracking approaches have been used to understand the visual search process in radiology. However, previous eye‐tracking work in computer tomography (CT) has been limited largely to single cross‐sectional images or video playback of the reconstructed volume, which do not accurately reflect radiologists' visual search activities and their interactivity with three‐dimensional image data at a computer workstation (e.g., scroll, pan, and zoom) for visual evaluation of diagnostic imaging targets. We have developed a platform that integrates eye‐tracking hardware with in‐house‐developed reader workstation software to allow monitoring of the visual search process and reader‐image interactions in clinically relevant reader tasks. The purpose of this work is to validate the spatial accuracy of eye‐tracking data using this platform for different eye‐tracking data acquisition modes.MethodsAn eye‐tracker was integrated with a previously developed workstation designed for reader performance studies. The integrated system captured real‐time eye movement and workstation events at 1000 Hz sampling frequency. The eye‐tracker was operated either in head‐stabilized mode or in free‐movement mode. In head‐stabilized mode, the reader positioned their head on a manufacturer‐provided chinrest. In free‐movement mode, a biofeedback tool emitted an audio cue when the head position was outside the data collection range (general biofeedback) or outside a narrower range of positions near the calibration position (strict biofeedback). Four radiologists and one resident were invited to participate in three studies to determine eye‐tracking spatial accuracy under three constraint conditions: head‐stabilized mode (i.e., with use of a chin rest), free movement with general biofeedback, and free movement with strict biofeedback. Study 1 evaluated the impact of head stabilization versus general or strict biofeedback using a cross‐hair target prior to the integration of the eye‐tracker with the image viewing workstation. In Study 2, after integration of the eye‐tracker and reader workstation, readers were asked to fixate on targets that were randomly distributed within a volumetric digital phantom. In Study 3, readers used the integrated system to scroll through volumetric patient CT angiographic images while fixating on the centerline of designated blood vessels (from the left coronary artery to dorsalis pedis artery). Spatial accuracy was quantified as the offset between the center of the intended target and the detected fixation using units of image pixels and the degree of visual angle.ResultsThe three head position constraint conditions yielded comparable accuracy in the studies using digital phantoms. For Study 1 involving the digital crosshairs, the median ± the standard deviation of offset values among readers were 15.2 ± 7.0 image pixels with the chinrest, 14.2 ± 3.6 image pixels with strict biofeedback, and 19.1 ± 6.5 image pixels with general biofeedback. For Study 2 using the random dot phantom, the median ± standard deviation offset values were 16.7 ± 28.8 pixels with use of a chinrest, 16.5 ± 24.6 pixels using strict biofeedback, and 18.0 ± 22.4 pixels using general biofeedback, which translated to a visual angle of about 0.8° for all three conditions. We found no obvious association between eye‐tracking accuracy and target size or view time. In Study 3 viewing patient images, use of the chinrest and strict biofeedback demonstrated comparable accuracy, while the use of general biofeedback demonstrated a slightly worse accuracy. The median ± standard deviation of offset values were 14.8 ± 11.4 pixels with use of a chinrest, 21.0 ± 16.2 pixels using strict biofeedback, and 29.7 ± 20.9 image pixels using general biofeedback. These corresponded to visual angles ranging from 0.7° to 1.3°.ConclusionsAn integrated eye‐tracker system to assess reader eye movement and interactive viewing in relation to imaging targets demonstrated reasonable spatial accuracy for assessment of visual fixation. The head‐free movement condition with audio biofeedback performed similarly to head‐stabilized mode.
Role of imaging in multiple myeloma
Baffour, Francis , Glazebrook, Katrina N. , Kumar, Shaji , Baffour, Francis I , Broski, Stephen M.

American Journal of Hematology | April 30, 2020 | Volume: 95 | Issue: 8 | Pages: 966-977

10.1002/ajh.25846 Get It

AbstractWith rapid advancements in the diagnosis and treatment of multiple myeloma (MM), imaging has become instrumental in detection of intramedullary and extramedullary disease, providing prognostic information, and assessing therapeutic efficacy. Whole‐body low dose computed tomography (WBLDCT) has emerged as the study of choice to detect osteolytic bone disease. Positron emission tomography/computed tomography (PET/CT) combines functional and morphologic information to identify MM disease activity and assess treatment response. Magnetic resonance imaging (MRI) has excellent soft‐tissue contrast and is the modality of choice for bone marrow evaluation. This review focuses on the imaging modalities available for MM patient management, highlighting advantages, disadvantages, and applications of each.
Regional assessment of in vivo myocardial stiffness using 3D magnetic resonance elastography in a porcine model of myocardial infarction
Arunachalam, Shivaram P. , Arani, Arvin , Baffour, Francis , Rysavý, J, Rossman, Phillip J. , Glaser, Kevin J. , Lake, David S. , Trzasko, Joshua D. , McGee, Kiaran P. , Araoz, Philip A. , Rysavy, Joseph A, Manduca, Armando , Ehman, Richard L. , Arunachalam, S P , Arani, Arvin , Baffour, Francis I

Magnetic Resonance in Medicine | April 6, 2017 | Volume: 79 | Issue: 1 | Pages: 361-369

10.1002/mrm.26695 Get It

Purpose The stiffness of a myocardial infarct affects the left ventricular pump function and remodeling. Magnetic resonance elastography (MRE) is a noninvasive imaging technique for measuring soft‐tissue stiffness in vivo. The purpose of this study was to investigate the feasibility of assessing in vivo regional myocardial stiffness with high‐frequency 3D cardiac MRE in a porcine model of myocardial infarction, and compare the results with ex vivo uniaxial tensile testing. Methods Myocardial infarct was induced in a porcine model by embolizing the left circumflex artery. Fourteen days postinfarction, MRE imaging was performed in diastole using an echocardiogram‐gated spin‐echo echo‐planar‐imaging sequence with 140‐Hz vibrations and 3D MRE processing. The MRE stiffness and tensile modulus from uniaxial testing were compared between the remote and infarcted myocardium. Results Myocardial infarcts showed increased in vivo MRE stiffness compared with remote myocardium (4.6 ± 0.7 kPa versus 3.0 ± 0.6 kPa, P = 0.02) within the same pig. Ex vivo uniaxial mechanical testing confirmed the in vivo MRE results, showing that myocardial infarcts were stiffer than remote myocardium (650 ± 80 kPa versus 110 ± 20 kPa, P = 0.01). Conclusions These results demonstrate the feasibility of assessing in vivo regional myocardial stiffness with high‐frequency 3D cardiac MRE. Magn Reson Med 79:361–369, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Cardiac MR elastography for quantitative assessment of elevated myocardial stiffness in cardiac amyloidosis
Arani, Arvin , Arunachalam, Shivaram P. , Chang, Ian C , Baffour, Francis , Rossman, Phillip J. , Glaser, Kevin J. , Trzasko, Joshua D. , McGee, Kiaran P. , Grogan, Martha , Dispenzieri, Angela , Araoz, Philip A. , Chang, Ian C Y, Manduca, Armando , Ehman, Richard L. , Dispenzieri, Angela , Arunachalam, S P , Arani, Arvin , Baffour, Francis I

Journal of Magnetic Resonance Imaging | February 25, 2017 | Volume: 46 | Issue: 5 | Pages: 1361-1367

10.1002/jmri.25678 Get It

PurposeTo evaluate if cardiac magnetic resonance elastography (MRE) can measure increased stiffness in patients with cardiac amyloidosis. Myocardial tissue stiffness plays an important role in cardiac function. A noninvasive quantitative imaging technique capable of measuring myocardial stiffness could aid in disease diagnosis, therapy monitoring, and disease prognostic strategies. We recently developed a high‐frequency cardiac MRE technique capable of making noninvasive stiffness measurements.Materials and MethodsIn all, 16 volunteers and 22 patients with cardiac amyloidosis were enrolled in this study after Institutional Review Board approval and obtaining formal written consent. All subjects were imaged head‐first in the supine position in a 1.5T closed‐bore MR imager. 3D MRE was performed using 5 mm isotropic resolution oblique short‐axis slices and a vibration frequency of 140 Hz to obtain global quantitativein vivoleft ventricular stiffness measurements. The median stiffness was compared between the two cohorts. An octahedral shear strain signal‐to‐noise ratio (OSS‐SNR) threshold of 1.17 was used to exclude exams with insufficient motion amplitude.ResultsFive volunteers and six patients had to be excluded from the study because they fell below the 1.17 OSS‐SNR threshold. The myocardial stiffness of cardiac amyloid patients (median: 11.4 kPa, min: 9.2, max: 15.7) was significantly higher (P = 0.0008) than normal controls (median: 8.2 kPa, min: 7.2, max: 11.8).ConclusionThis study demonstrates the feasibility of 3D high‐frequency cardiac MRE as a contrast‐agent‐free diagnostic imaging technique for cardiac amyloidosis.Level of Evidence:2Technical Efficacy:Stage 2J. Magn. Reson. Imaging 2017;46:1361–1367.