Abstract Background and study aims Obtaining quality tissue during ERCP biliary stricture sampling is of paramount importance for a timely diagnosis. While single-operator cholangioscopy (SOC)-guided biopsies have been suggested to be the superior biliary tissue acquisition modality given direct tissue visualization, less is known about the specimen histological quality. We aimed to analyze the specimen quality of SOC biopsies and compare the new generation forceps with prior “legacy” forceps. Patients and methods Patients who underwent SOC from January 2017-August 2021 for biliary sampling were reviewed. In February 2020, the SOC-guided biopsy forceps were changed from legacy SpyBite to the SpyBite Max forceps (max). Specimens were assessed by blinded pathologists for crush artifact (none, mild, or severe) and gross size (greatest dimension in mm). Crush artifact and gross size were compared between the two groups. The diagnostic performance characteristics for cholangiocarcinoma (CCA), were assessed in an exploratory fashion. Results Eighty-one patients (max = 27, legacy = 54) with similar baseline characteristics were included in this study. On blinded pathological assessment, 58 % had crush artifact, without significant differences between the two groups (Max 63 % vs. Legacy 56 %; P = 0.64). A similar mean specimen size was found (max 3 mm vs. legacy 3.2 mm; P = 0.24). The overall prevalence of CCA was 40 %. The sensitivity, specificity, positive predictive value, and negative predictive value of the entire cohort using a combination of cytology, fluorescence in situ hybridization, and SOC-guided biopsies were 78.1 %, 91.8 %, 86.2 %, and 86.5 %, respectively. No difference between legacy or max groups was found. Conclusions A high rate of crush artifact was found in SOC-guided biopsy specimens. Further investigation regarding proper biopsy technique and handling is necessary to increase the diagnostic yield with SOC-guided biopsies.
Consensus-based development of a causal attribution system for post-ERCP adverse events
The benefit of endoscopic retrograde cholangiopancreatography (ERCP) for the treatment of primary sclerosing cholangitis (PSC) remains controversial. To identify predictors of jaundice resolution after ERCP and whether resolution is associated with improved patient outcomes, we conducted a retrospective cohort study of 124 patients with jaundice and PSC. These patients underwent endoscopic biliary balloon dilation and/or stent placement at an American tertiary center, with validation in a separate cohort of 102 patients from European centers. Jaundice resolved after ERCP in 52% of patients. Median follow‐up was 4.8 years. Independent predictors of jaundice resolution included older age (P = 0.048; odds ratio [OR], 1.03 for every 1‐year increase), shorter duration of jaundice (P = 0.059; OR, 0.59 for every 1‐year increase), lower Mayo Risk Score (MRS) (P = 0.025; OR, 0.58 for every 1‐point increase), and extrahepatic location of the most advanced biliary stricture (P = 0.011; OR, 3.13). A logistic regression model predicted jaundice resolution with area under the receiver operator characteristic curve of 0.67 (95% confidence interval, 0.5‐0.79) in the validation set. Independent predictors of death or transplant during follow‐up included higher MRS at the time of ERCP (P < 0.0001; hazard ratio [HR], 2.33 for every 1‐point increase), lower total serum bilirubin before ERCP (P = 0.031; HR, 0.91 for every 1 mg/dL increase), and persistence of jaundice after endoscopic therapy (P = 0.003; HR, 2.30). Conclusion: Resolution of jaundice after endoscopic treatment of biliary strictures is associated with longer transplant‐free survival of patients with PSC. The likelihood of resolution is affected by demographic, hepatic, and biliary variables and can be predicted using noninvasive data. These findings may refine the use of ERCP in patients with jaundice with PSC.
Go With the Flow: Alternative Terminology in Relational Anatomy
INTRODUCTION: Exogenous transmission of infection via duodenoscope cross-contamination after failed disinfection is a preventable risk. Inadequate reprocessing of reusable duodenoscopes can occur. Given this possibility, a new single-use duodenoscope was recently developed. It had comparable performance to reusable duodenoscopes when tested by expert endoscopists in a comparative bench model for endoscopic retrograde cholangiopancreatography (ERCP). We subsequently aimed to assess the performance of this disposable duodenoscope in a series of human cases. METHODS: Six academic medical centers enrolled consecutive adults 18 years or older without altered pancreaticobiliary anatomy scheduled for an ERCP. Seven ERCP experts rated the new EXALT single-use Model D duodenoscope (Boston Scientific, Marlborough, MA; ClinicalTrials.gov NCT03701958) in ERCP procedures for Overall Satisfaction on a scale of 1 (unsatisfied) to 10 (very satisfied), “Not preferred/Neutral/Preferred” compared to reusable duodenoscopes on 23 ERCP maneuvers, and Qualitative Comparison of 17 performance characteristics on a scale of 1 (not preferred) to 5 (comparable to reusable duodenoscopes). RESULTS: Sixty consecutive patients had an ERCP using the first-generation single-use duodenoscope in April and May 2019. Thirty-seven (61.7%) were male, mean age was 64.4 years, and 44 (73.3%) had a prior ERCP at baseline. All 60 ERCP procedures were successfully performed, 58 (96.7%) with the single-use duodenoscope alone and 2 (3.3%) with crossover to a reusable duodenoscope. Median overall satisfaction with the single-use duodenoscope was rated 9.0 (range 1-10). The overall satisfaction rating was ≥ 7 in 56 (93.3%) ERCPs. All three ratings were at or above midpoint (Overall satisfaction ≥ 5, Comparative ERCP maneuver “Neutral/Preferred,” Qualitative Comparative rating of performance characteristic 3-5) in 47 (78.3%) cases. Four ERCPs had low (≤4) overall satisfaction ratings attributed to inadequate pushability of instruments due to suboptimal positioning of the duodenoscope in front of the papilla; these ERCPs were a subset in which biliary or pancreatic duct strictures were dilated and/or stented. CONCLUSION: Expert endoscopists reported good overall performance of a new single-use duodenoscope in a broad array of cases. Low ratings occurred rarely and were associated with particular ERCP maneuvers. Detailed design improvements to the single-use duodenoscope are underway.
The string sign for diagnosis of mucinous pancreatic cysts
Background. The SpyGlass Direct Visualization System (Boston Scientific, Natick, MA) is routinely used during single operator choledochoscopy (SOC) to identify biliary lesions or strictures with a diagnostic accuracy up to 88%. The objective of this study was to determine the interobserver agreement (IOA) of modified scoring criteria for diagnosing biliary lesions/strictures. Methods. 27 SPY SOC video clips were reviewed and scored by 9 interventional endoscopists based on published criteria that included the presence and severity of surface structure, vasculature visualization, lesions, and findings. Results. Overall IOA was “slight” for all variables. The K statistics are as follows: surface (K=0.12, SE = 0.02); vessels (K=0.14, SE = 0.02); lesions (K=0.11, SE = 0.02); findings (K=0.08, SE = 0.03); and final diagnosis (K=0.08, SE = 0.02). The IOA for “findings” and “final diagnosis” was also only “slight.” The final diagnosis was malignant (11), benign (11), and indeterminate (5). Conclusion. IOA using the modified criteria of SOC images was slight to almost poor. The average accuracy was less than 50%. These findings reaffirm that imaging criteria for benign and malignant biliary pathology need to be formally established and validated.