Breast cancer is the second-leading cause of mortality among women around the world. Ultrasound (US) is one of the noninvasive imaging modalities used to diagnose breast lesions and monitor the prognosis of cancer patients. It has the highest sensitivity for diagnosing breast masses, but it shows increased false negativity due to its high operator dependency. Underserved areas do not have sufficient US expertise to diagnose breast lesions, resulting in delayed management of breast lesions. Deep learning neural networks may have the potential to facilitate early decision-making by physicians by rapidly yet accurately diagnosing and monitoring their prognosis. This article reviews the recent research trends on neural networks for breast mass ultrasound, including and beyond diagnosis. We discussed original research recently conducted to analyze which modes of ultrasound and which models have been used for which purposes, and where they show the best performance. Our analysis reveals that lesion classification showed the highest performance compared to those used for other purposes. We also found that fewer studies were performed for prognosis than diagnosis. We also discussed the limitations and future directions of ongoing research on neural networks for breast ultrasound.
Quantitative Biomarkers Derived from a Novel Contrast-Free Ultrasound High-Definition Microvessel Imaging for Distinguishing Thyroid Nodules
Low specificity in current ultrasound modalities for thyroid cancer detection necessitates the development of new imaging modalities for optimal characterization of thyroid nodules. Herein, the quantitative biomarkers of a new high-definition microvessel imaging (HDMI) were evaluated for discrimination of benign from malignant thyroid nodules. Without the help of contrast agents, this new ultrasound-based quantitative technique utilizes processing methods including clutter filtering, denoising, vessel enhancement filtering, morphological filtering, and vessel segmentation to resolve tumor microvessels at size scales of a few hundred microns and enables the extraction of vessel morphological features as new tumor biomarkers. We evaluated quantitative HDMI on 92 patients with 92 thyroid nodules identified in ultrasound. A total of 12 biomarkers derived from vessel morphological parameters were associated with pathology results. Using the Wilcoxon rank-sum test, six of the twelve biomarkers were significantly different in distribution between the malignant and benign nodules (all p < 0.01). A support vector machine (SVM)-based classification model was trained on these six biomarkers, and the receiver operating characteristic curve (ROC) showed an area under the curve (AUC) of 0.9005 (95% CI: [0.8279,0.9732]) with sensitivity, specificity, and accuracy of 0.7778, 0.9474, and 0.8929, respectively. When additional clinical data, namely TI-RADS, age, and nodule size were added to the features, model performance reached an AUC of 0.9044 (95% CI: [0.8331,0.9757]) with sensitivity, specificity, and accuracy of 0.8750, 0.8235, and 0.8400, respectively. Our findings suggest that tumor vessel morphological features may improve the characterization of thyroid nodules.
Variability in Lipid Levels and Risk for Cardiovascular Disease: An Electronic Health Record–Based Population Cohort Study
Background Larger within‐patient variability of lipid levels has been associated with increased risk of cardiovascular disease (CVD); however, measures of lipid variability require ≥3 measurements and are not currently used clinically. We investigated the feasibility of calculating lipid variability within a large electronic health record–based population cohort and assessed associations with incident CVD. Methods and Results We identified all individuals ≥40 years of age who resided in Olmsted County, MN, on January 1, 2006 (index date), without prior CVD, defined as myocardial infarction, coronary artery bypass graft surgery, percutaneous coronary intervention, or CVD death. Patients with ≥3 measurements of total cholesterol, low‐density lipoprotein cholesterol, high‐density lipoprotein cholesterol, or triglycerides during the 5 years before the index date were retained. Lipid variability was calculated using variability independent of the mean. Patients were followed through December 31, 2020 for incident CVD. We identified 19 652 individuals (mean age 61 years; 55% female), who were CVD‐free and had variability independent of the mean calculated for at least 1 lipid type. After adjustment, those with highest total cholesterol variability had a 20% increased risk of CVD (Q5 versus Q1 hazard ratio, 1.20 [95% CI, 1.06–1.37]). Results were similar for low‐density lipoprotein cholesterol and high‐density lipoprotein cholesterol. Conclusions In a large electronic health record–based population cohort, high variability in total cholesterol, high‐density lipoprotein cholesterol, and low‐density lipoprotein cholesterol was associated with an increased risk of CVD, independent of traditional risk factors, suggesting it may be a possible risk marker and target for intervention. Lipid variability can be calculated in the electronic health record environment, but more research is needed to determine its clinical utility.
High-Pitch Multienergy Coronary CT Angiography in Dual-Source Photon-Counting Detector CT Scanner at Low Iodinated Contrast Dose
Objectives The aim of this study was to evaluate the high-helical pitch, multienergy (ME) scanning mode of a clinical dual-source photon-counting detector (PCD) computed tomography (CT) and the benefit of virtual monoenergetic images (VMIs) for low-contrast-dose coronary CT angiography (CTA). Materials and Methods High-pitch (3.2) ME coronary CTA was performed in PCD-CT in 27 patients using low contrast dose (30 mL of iohexol 350 mg/mL) and in 26 patients at routine contrast dose (60 mL). Low-energy-threshold 120 kV images (also known as T3D images) and 50 kiloelectron volts (50 keV) and 100 kiloelectron volts (100 keV) VMIs were reconstructed using a 1024 × 1024 matrix and 0.6-mm slices. The CT numbers, noise, and contrast-to-noise ratio (CNR) were measured in the ascending aorta (AA), left main coronary artery (LMCA), and distal left anterior descending (LAD) artery. Confidence in grading luminal stenosis with calcific plaque, noncalcific plaque, and stent was evaluated by 2 independent readers on a 0–100 scale (0 the lowest), and a CAD-RADS score was assigned. Image contrast enhancement, sharpness, noise, artifacts, and overall image quality were rated using a 5-point ordinal scale (1 the lowest). Results The radiation doses (CTDI) in low- and routine-contrast cohorts were 2.5 ± 0.6 mGy and 3.1 ± 1.7 mGy, respectively ( P = 0.12). At all measured locations, the mean CT number was >300 HU in 120 kV (LMCA 382.9 ± 76.2, distal LAD 341.0 ± 53.9, AA 399.5 ± 76.1) and 50 keV images (LMCA 667.5 ± 139.9, distal LAD 578.1 ± 121.5, AA 700.8 ± 142.5) in the low-contrast cohort, with a 96% increase in CT numbers for 50 keV over 120 kV. The CT numbers were significantly higher ( P < 0.0001) in 50 keV than 120 kV and 100 keV VMI. The CNR was also significantly ( P < 0.0001) higher in 50 keV than 120 kV and 100 keV images in all vessels. Confidence in the assessment of luminal stenosis in the presence of calcific plaque was significantly higher ( P = 0.001) with the addition of 100 keV VMI (median score, 100) than using 50 keV alone (median score, 70) and 120 kV (median score, 70) for reader 1, but no significant differences were seen for reader 2 who had same median scores of 100 for all image types. The confidence in the assessment of luminal stenosis within a stent improved with the use of 100 keV images for both readers (reader 1: median scores for 50 + 100 keV = 100, 50 keV = 82.5, 120 kV = 82.5; reader 2: 50 + 100 keV = 100, 50 keV = 90, 120 kV = 90). There were no significant differences in confidence scores for assessment of luminal stenosis from noncalcific plaques for both readers. The reader-averaged qualitative scores for vascular enhancement and overall image quality were significantly higher for 50 keV VMI than for 120 kV images in both low- and routine-contrast dose cohorts. The image sharpness was nonsignificantly higher at 50 keV VMI than 120 kV images, and the artifact score was comparable for 50 keV VMI and 120 kV images. The noise was higher in 50 keV VMI than in 120 kV images. Conclusions High-pitch ME PCD-CT mode produced diagnostic quality coronary CTA images at low radiation and iodinated contrast doses. The availability of ME VMIs significantly improved the CNR, overall image quality, and confidence in assessment of luminal stenosis in the presence of calcific plaques and stents, and resulted in change of CAD-RADS categories in 9 patients.
Improved cochlear implant electrode localization using coregistration of pre‐ and postoperative CT
Abstract Background and Purpose Artifact from cochlear implant electrodes degrades image resolution on CT. Here, we describe the use of coregistered pre‐ and postoperative CT images to reduce metallic artifact from the electrodes to assess its position more accurately within the cochlear lumen. Methods Pre‐ and postoperative CTs were reviewed after coregistration/overlay of both exams. Images were evaluated by two neuroradiologists for scalar location of electrodes tip (± scalar translocation), tip fold over, and angular depth of insertion. Results Thirty‐four patients were included in the final cohort. Transscalar migration was present in three (8.8%) cases (one case demonstrated tip fold over), with initial disagreement regarding transscalar migration in 1 out of 34 patients (2.9%). Agreement regarding depth of insertion was present in 31 (91.1%) cases. Five‐point Likert scales were used to compare the ability to resolve the proximity of electrodes to the lateral/outer cochlear wall without and with overlay, which is a qualitative measure of artifact from the array. Likert scores showed definitive benefit of metal artifact reduction using overlayed images with an average score of 4.34. Conclusion This study demonstrates a novel technique of using fused coregistration of pre‐ and postoperative CTs for the purpose of artifact reduction/electrode localization. It is anticipated that this technique will permit more accurate localization of the electrodes for improvement in surgical technique and electrode array design.
Predictors of Metformin Failure: Repurposing Electronic Health Record Data to Identify High-Risk Patients
Abstract Context Metformin is the first-line drug for treating diabetes but has a high failure rate. Objective To identify demographic and clinical factors available in the electronic health record (EHR) that predict metformin failure. Methods A cohort of patients with at least 1 abnormal diabetes screening test that initiated metformin was identified at 3 sites (Arizona, Mississippi, and Minnesota). We identified 22 047 metformin initiators (48% female, mean age of 57 ± 14 years) including 2141 African Americans, 440 Asians, 962 Other/Multiracial, 1539 Hispanics, and 16 764 non-Hispanic White people. We defined metformin failure as either the lack of a target glycated hemoglobin (HbA1c) (<7%) within 18 months of index or the start of dual therapy. We used tree-based extreme gradient boosting (XGBoost) models to assess overall risk prediction performance and relative contribution of individual factors when using EHR data for risk of metformin failure. Results In this large diverse population, we observed a high rate of metformin failure (43%). The XGBoost model that included baseline HbA1c, age, sex, and race/ethnicity corresponded to high discrimination performance (C-index of 0.731; 95% CI 0.722, 0.740) for risk of metformin failure. Baseline HbA1c corresponded to the largest feature performance with higher levels associated with metformin failure. The addition of other clinical factors improved model performance (0.745; 95% CI 0.737, 0.754, P < .0001). Conclusion Baseline HbA1c was the strongest predictor of metformin failure and additional factors substantially improved performance suggesting that routinely available clinical data could be used to identify patients at high risk of metformin failure who might benefit from closer monitoring and earlier treatment intensification.
Ultrasonographic Detection and Surgical Retrieval of a Nonmetallic Twinkle Marker in Breast Cancer: Pilot Study
Objective: Investigate the performance of multiparametric MRI radiomic features, alone or combined with current standard-of-care methods, for pulmonary nodule classification. Assess the impact of segmentation variability on feature reproducibility and reliability. Methods: Radiomic features were extracted from 74 pulmonary nodules of 68 patients who underwent nodule resection or biopsy after MRI exam. The MRI features were compared with histopathology and conventional quantitative imaging values (maximum standardized uptake value [SUVmax] and mean Hounsfield unit [HU]) to determine whether MRI radiomic features can differentiate types of nodules and associate with SUVmax and HU using Wilcoxon rank sum test and linear regression. Diagnostic performance of features and four machine learning (ML) models were evaluated with area under the receiver operating characteristic curve (AUC) and 95% confidence intervals (CIs). Concordance correlation coefficient (CCC) assessed the segmentation variation impact on feature reproducibility and reliability. Results: Elevn diffusion-weighted features distinguished malignant from benign nodules (adjusted p < 0.05, AUC: 0.73–0.81). No features differentiated cancer types. Sixty-seven multiparametric features associated with mean CT HU and 14 correlated with SUVmax. All significant MRI features outperformed traditional imaging parameters (SUVmax, mean HU, apparent diffusion coefficient [ADC], T1, T2, dynamic contrast-enhanced imaging values) in distinguishing malignant from benign nodules with some achieving statistical significance (p < 0.05). Adding ADC and smoking history improved feature performance. Machine learning models demonstrated strong performance in nodule classification, with extreme gradient boosting (XGBoost) having the highest discrimination (AUC = 0.83, CI=[0.727, 0.932]). We found good to excellent inter- and intrareader feature reproducibility and reliability (CCC≥0.80). Conclusion: Eleven MRI radiomic features differentiated malignant from benign lung nodules, outperforming traditional quantitative methods. MRI radiomic ML models demonstrated good nodule classification performances with XGBoost superior to three others. There was good to excellent inter- and intrareader feature reproducibility and reliability. Advances in knowledge: Our study identified MRI radiomic features that successfully differentiated malignant from benign lung nodules and demonstrated high performance of our MR radiomic feature-based ML models for nodule classification. These new findings could help further establish thoracic MRI as a non-invasive and radiation-free alternative to standard practice for pulmonary nodule assessment.
White Blood Cells and Chronic Rhinosinusitis: A Mendelian Randomization Study
Abstract Background Risk factors for the pathogenesis of chronic rhinosinusitis (CRS) remain largely undetermined, which is likely due to the heterogeneity of the disease. White blood cell counts have been largely unexplored as a risk factor for CRS even though different types of white blood cells are involved in the inflammatory process of CRS. Objective To investigate causal associations between different types of white blood cells on risk of CRS utilizing a Mendelian randomization (MR) analysis. Methods A two-sample MR analysis was performed using respective GWAS summary statistics for the exposure traits (neutrophil count, eosinophil count, basophil count, lymphocyte count, and monocyte count) and outcome trait (CRS). For the exposure traits, the European Bioinformatics Institute database of complete GWAS summary data was used. For the outcome trait, summary statistics for CRS GWAS were obtained from FinnGen. Primary analysis for MR was performed using inverse-variance weighted two-sample MR. Sensitivity analyses included weighted median, MR-Egger, and MR-PRESSO (raw and outlier-corrected). Results Eosinophils were associated with CRS (OR = 1.55 [95%CI 1.38,1.73]; p = 4.3E-14). Eosinophil results were similar across additional MR methods. MR results did not demonstrate significant causal relationships between neutrophils, lymphocytes, monocytes, or basophils with CRS. No significant pleiotropic bias was observed. Conclusions In a two-sample MR analysis, a potential causal link between blood eosinophil counts and CRS has been demonstrated. In addition, causal relationships between blood counts among other white blood cell types and CRS were not found. Further studies involving genetic variation in CRS are needed to corroborate genetic causal effects for CRS.
Photon-counting Detector CT with Deep Learning Noise Reduction to Detect Multiple Myeloma