Abstract Patients with core-binding factor (CBF) acute myeloid leukemia (AML), caused by either t(8;21)(q22;q22) or inv(16)(p13q22)/t(16;16)(p13;q22), have higher complete remission rates and longer survival than patients with other subtypes of AML. However, ∼40% of patients relapse, and the literature suggests that patients with inv(16) fare differently from those with t(8;21). We retrospectively analyzed 537 patients with CBF-AML, focusing on additional cytogenetic aberrations to examine their impact on clinical outcomes. Trisomies of chromosomes 8, 21, or 22 were significantly more common in patients with inv(16)/t(16;16): 16% vs 7%, 6% vs 0%, and 17% vs 0%, respectively. In contrast, del(9q) and loss of a sex chromosome were more frequent in patients with t(8;21): 15% vs 0.4% for del(9q), 37% vs 0% for loss of X in females, and 44% vs 5% for loss of Y in males. Hyperdiploidy was more frequent in patients with inv(16) (25% vs 9%, whereas hypodiploidy was more frequent in patients with t(8;21) (37% vs 3%. In multivariable analyses (adjusted for age, white blood counts at diagnosis, and KIT mutation status), trisomy 8 was associated with improved overall survival (OS) in inv(16), whereas the presence of other chromosomal abnormalities (not trisomy 8) was associated with decreased OS. In patients with t(8;21), hypodiploidy was associated with improved disease-free survival; hyperdiploidy and del(9q) were associated with improved OS. KIT mutation (either positive or not tested, compared with negative) conferred poor prognoses in univariate analysis only in patients with t(8;21).
Pathologic Spectrum and Molecular Landscape of Myeloid Disorders Harboring SF3B1 Mutations
Abstract Objectives SF3B1 mutations are the most common mutations in myelodysplastic syndromes (MDS). The International Working Group for the Prognosis of MDS (IWG-PM) recently proposed SF3B1-mutant MDS (SF3B1-mut-MDS) as a distinct disease subtype. We evaluated the spectrum and molecular landscape of SF3B1-mutated myeloid disorders and assessed the prognostication in MDS harboring SF3B1 mutations (MDS-SF3B1). Methods Cases were selected by retrospective review. Clinical course and laboratory and clinical findings were collected by chart review. SF3B1-mut-MDS was classified following IWG-PM criteria. Results SF3B1 mutations were identified in 75 of 955 patients, encompassing a full spectrum of myeloid disorders. In MDS-SF3B1, Revised International Prognostic Scoring System (IPSS-R) score greater than 3 and transcription factor (TF) comutations were adverse prognostic markers by both univariate and multivariate analyses. We confirmed the favorable outcome of IWG-PM-defined SF3B1-mut-MDS. Interestingly, it did not show sharp prognostic differentiation within MDS-SF3B1. Conclusions SF3B1 mutations occur in the full spectrum of myeloid disorders. We independently validated the favorable prognostication of IWG-PM-defined SF3B1-mut-MDS. However it may not provide sharp prognostication within MDS-SF3B1 where IPSS-R and TF comutations were prognostic-informative. Larger cohort studies are warranted to verify these findings and refine MDS-SF3B1 prognostication.
Revisiting the effects of spectral interfering substances in optical end‐point coagulation assays
AbstractIntroductionHemolysis, icterus, and lipemia (HIL) are common pre‐analytical variables in the clinical laboratory. Understanding their effects on coagulation laboratory results is essential.MethodsHIL effects on the prothrombin time (PT), activated partial thromboplastin time (APTT), dilute Russell's viper venom time (DRVVT), thrombin time (TT), and protein C chromogenic activity (CFx) were evaluated on the ACL TOP 750 optical analyzer and STA‐R Evolution mechanical analyzer (PT and APTT only) by spiking normal donor, patient, and commercial control samples with varying concentrations of hemolysate, bilirubin, or a lipid emulsion. The relative difference or bias compared to the original results was determined.ResultsHemolysis (H) indices up to 900 mg/dL did not affect the APTT, PT, DRVVT Confirm, TT, and CFx; however, H indices above approximately 200 mg/dL resulted in a false‐negative DRVVT screen and screen/confirm ratio in samples with a lupus anticoagulant. There was an artifactual prolongation of the PT and APTT when conjugated bilirubin was dissolved in aqueous solvents and not when it was dissolved in dimethyl sulfoxide. Icterus (I) indices up to 45 mg/dL did not result in significant (>15%) bias for all assays evaluated. The PT and APTT assays failed to produce a robust clot curve when the lipemia (L) index exceeded 6000 milliabsorbance units (mAbs), and the TT and DRVVT assays failed when the L index exceeded 3000 mAbs; the CFx assay was unaffected by lipemia.ConclusionsVerification of the manufacturer's recommended interference thresholds is important since it may avoid inappropriate instrument flagging and/ or sample rejection.
Platelet transfusion: The effects of a fluid warmer on platelet function
BackgroundPlatelet (PLT) transfusions are an important component of hemostatic resuscitation. The AABB has published several guidelines recommending that PLT units should not be infused through blood warming devices.Study Design and MethodsThirty‐one units of hospital blood bank apheresis PLTs were obtained. PLT‐rich plasma (PRP) aggregometry and thromboelastography (TEG) were performed on the unit samples before and after the units were infused through a Ranger blood/fluid warming device.ResultsThere were no differences in any of the aggregometry results before and after infusion of the PLTs through the blood warmer (all P > .32). There was a significant reduction in the TEG maximum amplitude (MA) of 69.8 ± 7.9 mm before and 66.0 ± 8.8 mm after (P < .001) infusion of the PLTs through the blood warmer and α angle 61.8 ± 9.4° before and 59.3 ± 8.2° after (P = .044) infusion of the PLTs through the blood warmer, although both mean values were within normal range for the TEG and not clinically significant. There were very good correlations of aggregometry and TEG results before and after infusion of the PLTs through the blood warmer device.ConclusionThis study did not demonstrate significant deleterious effect on PLT function from infusing apheresis PLT units through a blood warming device by PRP aggregometry. We did detect a statistically significant—but not clinically significant—reduction in TEG MA and α angle. The prohibition of transfusing PLT units though the Ranger blood warming device is not indicated.
Core‐binding factor acute myeloid leukemia with inv(16): Older age and high white blood cell count are risk factors for treatment failure
Abstract Heparin-induced thrombocytopenia (HIT) is a life-threatening, prothrombotic, antibody-mediated disorder. To maximize the likelihood of recovery, early and accurate diagnosis is critical. Widely available HIT assays, such as the platelet factor 4 (PF4) heparin enzyme-linked immunosorbent assay (ELISA) lack specificity, and the gold-standard carbon 14–labeled serotonin release assay (SRA) is of limited value for early patient management because it is available only through reference laboratories. Recent studies have demonstrated that pathogenic HIT antibodies selectively activate PF4-treated platelets and that a technically simpler assay, the PF4-dependent P-selectin expression assay (PEA), may provide an option for rapid and conclusive results. Based upon predefined criteria that combined 4Ts scores and HIT ELISA results, 409 consecutive adults suspected of having HIT were classified as disease positive, negative, or indeterminate. Patients deemed HIT indeterminate were considered disease negative in the primary analysis and disease positive in a sensitivity analysis. The ability of PEA and SRA to identify patients judged to have HIT was compared using receiver operating characteristic curve statistics. Using these predefined criteria, the diagnostic accuracy of PEA was high (area under the curve [AUC], 0.94; 95% confidence interval [CI], 0.87-1.0) and similar to that of SRA (AUC, 0.91; 95% CI, 0.82-1.0). In sensitivity analysis, the AUCs of PEA and SRA were also similar at 0.88 (95% CI, 0.78-0.98) and 0.86 (95% CI, 0.77-0.96), respectively. The PEA, a technically simple nonradioactive assay that uses ∼20-fold fewer platelets compared with the SRA, had high accuracy for diagnosing HIT. Widespread use of the PEA may facilitate timely and more effective management of patients with suspected HIT.
Characteristics of late transplant‐associated thrombotic microangiopathy in patients who underwent allogeneic hematopoietic stem cell transplantation
AbstractTransplant‐associated thrombotic microangiopathy (TA‐TMA) has a wide range of presentations after hematopoietic stem‐cell transplantation (HSCT). We retrospectively studied the risk factors and outcomes of patients with early (≤day 100) and late (>day 100) TA‐TMA. Among the 1451 HSCT recipients, early TA‐TMA occurred in 45 (3.1%) patients at a median of 27 (3‐91) days, and late TA‐TMA in 39 (2.7%) patients at a median of 303 (122‐2595) days. Patients with early TA‐TMA were more likely to have high blood calcineurin‐inhibitor levels (P < .001) and acute graph‐vs‐host disease (GVHD, P < .001), while late TMA patients were more likely to have chronic GVHD (P < .001). The estimated median overall survival after onset of TMA for the entire cohort was 6 months. The estimated median overall survival was not reached in patients with an improvement of TMA vs 2 months in patients with no improvement (P < .001). In the early TMA group, older age (for every 10 years, HR 1.40; 95% CI 1.00‐1.94; P = .049) and bacterial infection (HR 2.42; 95% CI 0.98‐6.00; P = .056) were positively associated with mortality. Switching to MMF treatment (HR 0.40; 95% CI 0.16‐0.99; P = .047) and improvement of TMA (HR 0.08; 95% CI 0.03‐0.25; P < .001) were negatively associated with mortality in the multivariate analysis. In the late TMA group, the improvement of TMA was the only independent predictor associated with a lower risk of death (HR 0.05; 95% CI 0.02‐0.19; P < .001). Mortality rates in both early and late TMA remain unacceptably high. Future studies are needed for early diagnosis, trigger identifications, and use of targeted treatments.
Aetiology and outcomes of secondary myelofibrosis occurring in the context of inherited platelet disorders: A single institutional study of four patients
Abstract Objectives Despite more than 40 years of experience performing the Bethesda assay (BA), poor intra- and interlaboratory precision remains the biggest laboratory challenge to date. Methods The BA procedure was modeled using stochastic simulation techniques to determine the precision of the BA up to dilutions of 1:4,096, to estimate the minimum significant relative change at various inhibitor titers, and to understand the laboratory procedural variables that could significantly affect the performance of the BA at high dilutions. Results Selecting the lowest dilution tube with a residual activity closest to 25% for calculating the reported Bethesda titer (BT), using a factor activity assay with a coefficient of variation less than or equal to 7.5% in the range of 15% to 50% factor activity level, performing the factor activity measurement in replicates, and minimizing pipette volumetric error resulted in the lowest imprecision in the reported BT. The factor neutralization kinetics of the inhibitor appear to have little impact on the precision of the assay if the incubation time is greater than 90 minutes. Conclusions This in silico model will assist future laboratory efforts in standardizing the quantification of specific coagulation factor inhibitors and improving the precision of the reported results.
PD-1/PD-L1 expression in extramedullary lesions of acute myeloid leukemia