PurposeTo develop a novel magnetic resonance elastography (MRE) acquisition using a hybrid radial EPI readout scheme (TURBINE), and to demonstrate its feasibility to obtain wave images and stiffness maps in a phantom and in vivo brain.MethodThe proposed 3D TURBINE‐MRE is based on a spoiled gradient‐echo MRE sequence with the EPI readout radially rotating about the phase‐encoding axis to sample a full 3D k‐space. A polyvinyl chloride phantom and 6 volunteers were scanned on a compact 3T GE scanner with a 32‐channel head coil at 80 Hz and 60 Hz external vibration, respectively. For comparison, a standard 2D, multislice, spin‐echo (SE) EPI‐MRE acquisition was also performed with the same motion encoding and resolution. The TURBINE‐MRE images were off‐line reconstructed with iterative SENSE algorithm. The regional ROI analysis was performed on the 6 volunteers, and the median stiffness values were compared between SE‐EPI‐MRE and TURBINE‐MRE.ResultsThe 3D wave‐field images and the generated stiffness maps were comparable between TURBINE‐MRE and standard SE‐EPI‐MRE for the phantom and the volunteers. The Bland–Altman plot showed no significant difference in the median regional stiffness values between the two methods. The stiffness measured with the 2 methods had a strong linear relationship with a Pearson correlation coefficient of 0.943.ConclusionWe demonstrated the feasibility of the new TURBINE‐MRE sequence for acquiring the desired 3D wave‐field data and stiffness maps in a phantom and in‐vivo brains. This pilot study encourages further exploration of TURBINE‐MRE for functional MRE, free‐breathing abdominal MRE, and cardiac MRE applications.
Across‐vendor standardization of semi‐LASER for single‐voxel MRS at 3T
Abstract The semi‐adiabatic localization by adiabatic selective refocusing (sLASER) sequence provides single‐shot full intensity signal with clean localization and minimal chemical shift displacement error and was recommended by the international MRS Consensus Group as the preferred localization sequence at high‐ and ultra‐high fields. Across‐vendor standardization of the sLASER sequence at 3 tesla has been challenging due to the B 1 requirements of the adiabatic inversion pulses and maximum B 1 limitations on some platforms. The aims of this study were to design a short‐echo sLASER sequence that can be executed within a B 1 limit of 15 μT by taking advantage of gradient‐modulated RF pulses, to implement it on three major platforms and to evaluate the between‐vendor reproducibility of its perfomance with phantoms and in vivo. In addition, voxel‐based first and second order B 0 shimming and voxel‐based B 1 adjustments of RF pulses were implemented on all platforms. Amongst the gradient‐modulated pulses considered (GOIA, FOCI and BASSI), GOIA‐WURST was identified as the optimal refocusing pulse that provides good voxel selection within a maximum B 1 of 15 μT based on localization efficiency, contamination error and ripple artifacts of the inversion profile. An sLASER sequence (30 ms echo time) that incorporates VAPOR water suppression and 3D outer volume suppression was implemented with identical parameters (RF pulse type and duration, spoiler gradients and inter‐pulse delays) on GE, Philips and Siemens and generated identical spectra on the GE ‘Braino’ phantom between vendors. High‐quality spectra were consistently obtained in multiple regions (cerebellar white matter, hippocampus, pons, posterior cingulate cortex and putamen) in the human brain across vendors (5 subjects scanned per vendor per region; mean signal‐to‐noise ratio > 33; mean water linewidth between 6.5 Hz to 11.4 Hz). The harmonized sLASER protocol is expected to produce high reproducibility of MRS across sites thereby allowing large multi‐site studies with clinical cohorts.
Modernizing Storage Conditions for Fresh Osteochondral Allografts by Optimizing Viability at Physiologic Temperatures and Conditions
Objective. Osteochondral allograft (OCA) transplantation has demonstrated good long-term outcomes in treatment of cartilage defects. Viability, a key factor in clinical success, decreases with peri-implantation storage at 4°C during pathogen testing, matching logistics, and transportation. Modern, physiologic storage conditions may improve viability and enhance outcomes. Design. Osteochondral specimens from total knee arthroplasty patients (6 males, 5 females, age 56.4 ± 2.2 years) were stored in media and incubated at normoxia (21% O 2 ) at 22°C or 37°C, and hypoxia (2% O 2 ) at 37°C. Histology, live-dead staining, and quantitative polymerase chain reaction (qPCR) was performed 24 hours after harvest and following 7 days of incubation. Tissue architecture, cell viability, and gene expression were analyzed. Results. No significant viability or gene expression deterioration of cartilage was observed 1-week postincubation at 37°C, with or without hypoxia. Baseline viable cell density (VCD) was 94.0% ± 2.7% at day 1. At day 7, VCD was 95.1% (37°C) with normoxic storage and 92.2% (37°C) with hypoxic storage ( P ≥ 0.27). Day 7 VCD (22°C) incubation was significantly lower than both the baseline and 37°C storage values (65.6%; P < 0.01). COL1A1, COL1A2, and ACAN qPCR expression was unchanged from baseline ( P < 0.05) for all storage conditions at day 7, while CD163 expression, indicative of inflammatory macrophages and monocytes, was significantly lower in the 37°C groups ( P < 0.01). Conclusion. Physiologic storage at 37°C demonstrates improved chondrocyte viability and metabolism, and maintained collagen expression compared with storage at 22°C. These novel findings guide development of a method to optimize short-term fresh OCA storage, which may lead to improved clinical results.
Identification of Anonymous MRI Research Participants with Face-Recognition Software
Magnetic resonance elastography (MRE) is increasingly being applied to thin or small structures in which wave propagation is dominated by waveguide effects, which can substantially bias stiffness results with common processing approaches. The purpose of this work was to investigate the importance of such biases and artifacts on MRE inversion results in: (i) various idealized 2D and 3D geometries with one or more dimensions that are small relative to the shear wavelength; and (ii) a realistic cardiac geometry. Finite element models were created using simple 2D geometries as well as a simplified and a realistic 3D cardiac geometry, and simulated displacements acquired by MRE from harmonic excitations from 60 to 220 Hz across a range of frequencies. The displacement wave fields were inverted with direct inversion of the Helmholtz equation with and without the application of bandpass filtering and/or the curl operator to the displacement field. In all geometries considered, and at all frequencies considered, strong biases and artifacts were present in inversion results when the curl operator was not applied. Bandpass filtering without the curl was not sufficient to yield accurate recovery. In the 3D geometries, strong biases and artifacts were present in 2D inversions even when the curl was applied, while only 3D inversions with application of the curl yielded accurate recovery of the complex shear modulus. These results establish that taking the curl of the wave field and performing a full 3D inversion are both necessary steps for accurate estimation of the shear modulus both in simple thin‐walled or small structures and in a realistic cardiac geometry when using simple inversions that neglect the hydrostatic pressure term. In practice, sufficient wave amplitude, signal‐to‐noise ratio, and resolution will be required to achieve accurate results.
MRI feature tracking strain is prognostic for all-cause mortality in AL amyloidosis