ABSTRACT Purpose Standard spatial‐spectral excitation pulses apply a fly‐back gradient between sub‐pulses, limiting, for example, how thin the slices can be (> 4 mm). Without fly‐back gradients, slices can be as thin as 1.7 mm but require a phase calibration for the sub‐pulses with inverted gradients due to system imperfections. Here we propose and test a fast (< 1 s), localized pre‐scan enabling thin‐slice frequency‐selective excitation. Methods The calibration pre‐scan determines the correction phase between even and odd sub‐pulses by measuring the phase difference of two FIDs excited with either the last or second‐to‐last RF sub‐pulse of the spatial‐spectral pulse. Non‐localized and localized versions of the calibration pre‐scan are tested and validated for water‐only excitation in phantoms and the human heart. As an example, breath‐held coronary MR angiography is performed with a spiral multi‐slice sequence employing the proposed pulses with a slice thickness of 1.7 mm. Results The proposed calibration pre‐scan takes 11.1 ms per slice, whether it is localized or not. Localized calibration phases are validated with an image‐based calibration map. Slice profiles are visualized for pulses with different time‐bandwidth products. Fat is suppressed to below 20% and 25% of the surrounding water signal in both phantoms and the human heart, respectively. High‐quality coronary angiograms are demonstrated in all test subjects. Conclusion Spatial‐spectral pulses without fly‐back gradients can be calibrated quickly (up to 90 slices in 1 s), enabling thinner slices, higher excitation angles, or pulses with sharper slice profiles using waveforms with higher time‐bandwidth products.
Real-time AI integration for MR to detect artifacts and guide pulse sequence adaptations
Abstract This work presents a first-of-its-kind artificial intelligence (AI-)integrated MR pulse sequence that detects out-of-voxel (OOV) artifacts in real-time (within-TR) and responds prospectively by updating the crusher gradient scheme. Per Excitation Real-time Execution & Guided Responses with Integrated Neural-network Evaluation (PEREGRINE), allows for deployment of deep learning models and pulse sequence updates. In this study, PEREGRINE operated a time-domain (TD) and frequency-domain (FD) convolutional autoencoder that detect OOV artifacts. Scans without (AI-off) and with (AI-on) updates were collected from the medial prefrontal cortex of healthy volunteers using a MEGA-edited MRS experiment. The degree of OOV contamination (OOV Score) was quantified per transient based upon the prevalence of OOV signals in the TD and FD data. OOV Scores above a user-defined threshold triggered an update of the crusher gradient scheme, iterating through 48 permutations (6 axis transpositions × 8 polarity flips). Within each 2-second TR, PEREGRINE successfully provided single-transient OOV Scores and updated gradients accordingly. No difference was observed between the OOV Scores from the full (“Full” condition) AI-on and AI-off sessions due to the AI-on scan cycling over better and worse gradient permutations relative to the AI-off scan. However, the AI-on scan had significantly lower OOV Scores than the AI-off scan when selecting the transients where PEREGRINE persisted (“Dwell” condition) on a given gradient permutation. Ultimately, Fit Quality Number (FQN) from linear combination modeling improved significantly for the AI-on compared to the AI-off scan. PEREGRINE enabled an adaptive and AI-integrated sequence allowing for real-time evaluation and response to OOV artifacts, identifying gradient modifications that produced less OOV contamination. Graphical Abstract Graphical Abstract Summary PEREGRINE, Per Excitation Real-time Execution & Guided Responses with Integrated Neural-network Evaluation, allows for pulse sequence updates using on-scanner deployed neural networks. To demonstrate the utility, PEREGRINE was used to operate two neural networks (time/frequency domain), trained to detect out-of-voxel artifacts, during a MEGA-edited MRS experiment in the prefrontal cortex. When artifacts were detected, PEREGRINE updated the crusher gradients within the same TR. Real-time, adaptive, and AI-driven MR will provide a long-awaited solution for combatting artifacts and poor data quality. Graphical Abstract Figure
Simultaneous Assessment of Skeletal Muscle Energetics and Blood Flow During Dynamic Exercise by Interleaved
31
P
‐
ABSTRACT Purpose To simultaneously measure skeletal muscle energetics and blood flow (BF) before, during, and after dynamic plantar flexion exercise (PFE). Methods Non‐localized pulse‐acquire phosphorus‐31 magnetic resonance spectroscopy ( 31 P MRS) and phase contrast flow magnetic resonance imaging ( 1 H MRI) using golden‐angle rotated spiral readouts were acquired in an interleaved fashion. Data were collected at rest, during PFE to volitional fatigue, and post‐exercise recovery in 10 healthy adults. Interleaved popliteal artery BF was validated against conventional cine phase‐contrast measures at rest and post‐exercise recovery, while calf muscle energetics were validated by comparing to conventional 31 P MRS‐only measures at rest. To minimize motion artifacts during dynamic PFE, flow data were resolved in 3 dimensions (cardiac phase, pedal position, and exercise stage). Results Resting phosphocreatine (PCr) and inorganic phosphate concentrations were similar between both techniques (both p > 0.05). During PFE, PCr declined to 46% ± 10% of rest. PCr recovery time was 43 ± 15 s. Resting BF was 132 ± 43 mL/min and increased up to four‐fold during PFE depending on exercise stage and pedal position. Notably, there was excellent agreement between the interleaved and conventional BF measures ( r 2 = 0.95, slope = 0.977, p < 0.0001) with minimal bias (12.62 mL/min) over a wide range of physiologically relevant BF values (from ∼60 to 600 mL/min). Conclusion The feasibility of simultaneous assessment of skeletal muscle energetics and BF during dynamic exercise by interleaved 31 P MRS/ 1 H flow MRI was demonstrated along with good agreement between interleaved and conventional techniques during rest and recovery. One can now simultaneously quantify critical BF‐metabolism relationships and use this to probe disease‐related adaptations.
Mitochondrial oxidative phosphorylation capacity in skeletal muscle measured by ultrafast
Z
‐spectroscopy (
UFZ
)
MRI
Abstract Purpose To investigate the feasibility of rapid CEST MRI acquisition for evaluating oxidative phosphorylation (OXPHOS) in human skeletal muscle at 3T, utilizing ultrafast Z‐spectroscopy (UFZ) combined with MRI and the Polynomial and Lorentzian line‐shape Fitting (PLOF) technique. Methods UFZ MRI on muscle was evaluated with turbo spin echo (TSE) and 3D EPI readouts. Five healthy subjects performed in‐magnet plantar flexion exercise (PFE) and subsequent changes of amide, PCr, and partial PCr mixed Cr (Cr + ) CEST dynamic signals post‐exercise were enabled by PLOF fitting. PCr/Cr CEST signal was further refined through pH correction by using the ratios between PCr/Cr and amide signals, named PCAR/CAR, respectively. Results UFZ MRI with TSE readout significantly reduces acquisition time, achieving a temporal resolution of <50 s for collecting high‐resolution Z‐spectra. Following PFE, the recovery/decay times (τ) for both PCr and Cr in the gastrocnemius muscle of the calf were notably longer when determined using PCr/Cr CEST compared to those after pH correction with amideCEST, namely = 87.1 ± 15.8 s and = 98.1 ± 20.4 s versus = 32.9 ± 19.7 s and = 43.0 ± 13.0 s, respectively. obtained via 31 P MRS ( = 50.3 ± 6.2 s) closely resemble those obtained from pH‐corrected PCr/Cr CEST signals. Conclusion The outcomes suggest potential of UFZ MRI as a robust tool for non‐invasive assessment of mitochondrial function in skeletal muscles. pH correction is critical for the reliable OXPHOS measurement by CEST.
Across‐vendor standardization of semi‐LASER for single‐voxel MRS at 3T
Abstract The semi‐adiabatic localization by adiabatic selective refocusing (sLASER) sequence provides single‐shot full intensity signal with clean localization and minimal chemical shift displacement error and was recommended by the international MRS Consensus Group as the preferred localization sequence at high‐ and ultra‐high fields. Across‐vendor standardization of the sLASER sequence at 3 tesla has been challenging due to the B 1 requirements of the adiabatic inversion pulses and maximum B 1 limitations on some platforms. The aims of this study were to design a short‐echo sLASER sequence that can be executed within a B 1 limit of 15 μT by taking advantage of gradient‐modulated RF pulses, to implement it on three major platforms and to evaluate the between‐vendor reproducibility of its perfomance with phantoms and in vivo. In addition, voxel‐based first and second order B 0 shimming and voxel‐based B 1 adjustments of RF pulses were implemented on all platforms. Amongst the gradient‐modulated pulses considered (GOIA, FOCI and BASSI), GOIA‐WURST was identified as the optimal refocusing pulse that provides good voxel selection within a maximum B 1 of 15 μT based on localization efficiency, contamination error and ripple artifacts of the inversion profile. An sLASER sequence (30 ms echo time) that incorporates VAPOR water suppression and 3D outer volume suppression was implemented with identical parameters (RF pulse type and duration, spoiler gradients and inter‐pulse delays) on GE, Philips and Siemens and generated identical spectra on the GE ‘Braino’ phantom between vendors. High‐quality spectra were consistently obtained in multiple regions (cerebellar white matter, hippocampus, pons, posterior cingulate cortex and putamen) in the human brain across vendors (5 subjects scanned per vendor per region; mean signal‐to‐noise ratio > 33; mean water linewidth between 6.5 Hz to 11.4 Hz). The harmonized sLASER protocol is expected to produce high reproducibility of MRS across sites thereby allowing large multi‐site studies with clinical cohorts.