Back to Authors

Gillen, Joseph

https://orcid.org/0000-0002-0734-2180

Mayo Clinic

Johns Hopkins University

Citations 2

Across‐vendor standardization of semi‐LASER for single‐voxel MRS at 3T
Deelchand, Dinesh K. , Berrington, Adam , Noeske, Ralph , Joers, James M. , Arani, Arvin , Gillen, Joseph , Nielsen, Jon‐Fredrik , Peltier, Scott , Seraji‐Bozorgzad, Navid , Juchem, Christoph , Soher, Brian J. , Kantarci, Kejal , Ratai, Eva, Barker, Peter B. , Öz, Gülin , Ratai, Eva‐Maria , Landheer, Karl , Öz, Gülin , Arani, Arvin , Kantarci, Kejal , Deelchand, Dinesh K , Schär, Michael , Noll, Douglas C. , Mareci, Thomas H.

NMR in Biomedicine | December 19, 2019 | Volume: 34 | Issue: 5 | Pages: No page available

10.1002/nbm.4218 Get It

Abstract The semi‐adiabatic localization by adiabatic selective refocusing (sLASER) sequence provides single‐shot full intensity signal with clean localization and minimal chemical shift displacement error and was recommended by the international MRS Consensus Group as the preferred localization sequence at high‐ and ultra‐high fields. Across‐vendor standardization of the sLASER sequence at 3 tesla has been challenging due to the B 1 requirements of the adiabatic inversion pulses and maximum B 1 limitations on some platforms. The aims of this study were to design a short‐echo sLASER sequence that can be executed within a B 1 limit of 15 μT by taking advantage of gradient‐modulated RF pulses, to implement it on three major platforms and to evaluate the between‐vendor reproducibility of its perfomance with phantoms and in vivo. In addition, voxel‐based first and second order B 0 shimming and voxel‐based B 1 adjustments of RF pulses were implemented on all platforms. Amongst the gradient‐modulated pulses considered (GOIA, FOCI and BASSI), GOIA‐WURST was identified as the optimal refocusing pulse that provides good voxel selection within a maximum B 1 of 15 μT based on localization efficiency, contamination error and ripple artifacts of the inversion profile. An sLASER sequence (30 ms echo time) that incorporates VAPOR water suppression and 3D outer volume suppression was implemented with identical parameters (RF pulse type and duration, spoiler gradients and inter‐pulse delays) on GE, Philips and Siemens and generated identical spectra on the GE ‘Braino’ phantom between vendors. High‐quality spectra were consistently obtained in multiple regions (cerebellar white matter, hippocampus, pons, posterior cingulate cortex and putamen) in the human brain across vendors (5 subjects scanned per vendor per region; mean signal‐to‐noise ratio > 33; mean water linewidth between 6.5 Hz to 11.4 Hz). The harmonized sLASER protocol is expected to produce high reproducibility of MRS across sites thereby allowing large multi‐site studies with clinical cohorts.
AutoVOI: real‐time automatic prescription of volume‐of‐interest for single voxel spectroscopy
Park, Young Woo , Deelchand, Dinesh K. , Joers, James M. , Hanna, Brian, Berrington, Adam , Gillen, Joseph , Kantarci, Kejal , Soher, Brian J. , Barker, Peter B. , Park, HyunWook , Öz, Gülin , Lenglet, Christophe , Öz, Gülin , Kantarci, Kejal , Deelchand, Dinesh K

Magnetic Resonance in Medicine | April 6, 2018 | Volume: 80 | Issue: 5 | Pages: 1787-1798

10.1002/mrm.27203 Get It

PurposeTo develop a fast and automated volume‐of‐interest (VOI) prescription pipeline (AutoVOI) for single‐voxel MRS that removes the need for manual VOI placement, allows flexible VOI planning in any brain region, and enables high inter‐ and intra‐subject consistency of VOI prescription.MethodsAutoVOI was designed to transfer pre‐defined VOIs from an atlas to the 3D anatomical data of the subject during the scan. The AutoVOI pipeline was optimized for consistency in VOI placement (precision), enhanced coverage of the targeted tissue (accuracy), and fast computation speed. The tool was evaluated against manual VOI placement using existing T1‐weighted data sets and corresponding VOI prescriptions. Finally, it was implemented on 2 scanner platforms to acquire MRS data from clinically relevant VOIs that span the cerebrum, cerebellum, and the brainstem.ResultsThe AutoVOI pipeline includes skull stripping, non‐linear registration of the atlas to the subject's brain, and computation of the VOI coordinates and angulations using a minimum oriented bounding box algorithm. When compared against manual prescription, AutoVOI showed higher intra‐ and inter‐subject spatial consistency, as quantified by generalized Dice coefficients (GDC), lower intra‐ and inter‐subject variability in tissue composition (gray matter, white matter, and cerebrospinal fluid) and higher or equal accuracy, as quantified by GDC of prescribed VOI with targeted tissues. High quality spectra were obtained on Siemens and Philips 3T systems from 6 automatically prescribed VOIs by the tool.ConclusionRobust automatic VOI prescription is feasible and can help facilitate clinical adoption of MRS by avoiding operator dependence of manual selection.