Abstract INTRODUCTION The Consortium for Clarity in Alzheimer's disease related dementias (ADRD) Research Through Imaging (CLARiTI) is a study that aims to collect standardized imaging and plasma biomarkers on 2000 Clinical Core participants enrolled across all Alzheimer's Disease Research Centers (ADRC) sites. We sought to summarize the known heterogeneity across centers regarding scientific focus and initial enrollment plans for CLARiTI. METHODS We developed and distributed a survey capturing information on the 36 CLARiTI site's theme/expertise, recruitment plans, and the intersection of CLARiTI with other ADRC imaging efforts. RESULTS Anticipated CLARiTI enrollees spanned 11 different categories of suspected etiologies underlying impairment. A wide range of risk factors were endorsed across sites regarding the enrollment of unimpaired individuals. Variability also existed regarding site‐level strategies in enrollment into CLARiTI versus other imaging efforts. DISCUSSION We anticipate that the 2000 individuals that will enroll into CLARiTI will reflect the clinical heterogeneity already in place across the ADRC network. Highlights The ADRC Consortium for Clarity in ADRD Research Through Imaging (CLARiTI) will leverage and contribute to the existing Alzheimer's Disease Research Centers (ADRC) program by supporting standardized imaging and plasma collection across all centers. We summarize the variation in scientific focus and enrollment plans across ADRC sites participating in CLARiTI. The anticipated CLARiTI cohort will reflect the clinical heterogeneity that already exists across the ADRC network. CLARiTI will contribute to scientific goals related to the detection of multi‐etiological signatures relevant for Alzheimer's disease and related disorders (ADRDs).
Across‐vendor standardization of semi‐LASER for single‐voxel MRS at 3T
Abstract The semi‐adiabatic localization by adiabatic selective refocusing (sLASER) sequence provides single‐shot full intensity signal with clean localization and minimal chemical shift displacement error and was recommended by the international MRS Consensus Group as the preferred localization sequence at high‐ and ultra‐high fields. Across‐vendor standardization of the sLASER sequence at 3 tesla has been challenging due to the B 1 requirements of the adiabatic inversion pulses and maximum B 1 limitations on some platforms. The aims of this study were to design a short‐echo sLASER sequence that can be executed within a B 1 limit of 15 μT by taking advantage of gradient‐modulated RF pulses, to implement it on three major platforms and to evaluate the between‐vendor reproducibility of its perfomance with phantoms and in vivo. In addition, voxel‐based first and second order B 0 shimming and voxel‐based B 1 adjustments of RF pulses were implemented on all platforms. Amongst the gradient‐modulated pulses considered (GOIA, FOCI and BASSI), GOIA‐WURST was identified as the optimal refocusing pulse that provides good voxel selection within a maximum B 1 of 15 μT based on localization efficiency, contamination error and ripple artifacts of the inversion profile. An sLASER sequence (30 ms echo time) that incorporates VAPOR water suppression and 3D outer volume suppression was implemented with identical parameters (RF pulse type and duration, spoiler gradients and inter‐pulse delays) on GE, Philips and Siemens and generated identical spectra on the GE ‘Braino’ phantom between vendors. High‐quality spectra were consistently obtained in multiple regions (cerebellar white matter, hippocampus, pons, posterior cingulate cortex and putamen) in the human brain across vendors (5 subjects scanned per vendor per region; mean signal‐to‐noise ratio > 33; mean water linewidth between 6.5 Hz to 11.4 Hz). The harmonized sLASER protocol is expected to produce high reproducibility of MRS across sites thereby allowing large multi‐site studies with clinical cohorts.