Citations 16

Aspirin Responsiveness in Healthy Volunteers Measured with Multiple Assay Platforms
Karon, Brad S. , Wockenfus, Amy M., Scott, Renee, Hartman, Stacy, McConnell, Joseph P., Santrach, Paula J., Jaffe, Allan S. , Jaffe, Allan S.

Clinical Chemistry | April 17, 2008 | Volume: 54 | Issue: 6 | Pages: 1060-1065

10.1373/clinchem.2007.101014 Get It

Abstract Background: We evaluated the sensitivity, precision, and concordance of 4 assays designed to detect aspirin responsiveness or resistance. Methods: Twenty-nine healthy laboratory volunteers took 80 mg aspirin for 7 days, and a subset of volunteers took 325 mg aspirin for an additional 7 days. We measured platelet function by light transmission aggregometry with arachidonic acid, PFA-100, and VerifyNow. PFA-100 and VerifyNow assays were performed in duplicate to assess method imprecision. Some volunteers had samples taken within 2–4 h of the final dose of aspirin and again within 20–24 h of the final dose. We measured urinary 11-dehydro-thromboxane B2 at baseline and after 80 or 325 mg aspirin. Results: No volunteers were nonresponsive to aspirin therapy as measured by the PFA-100. One of 29 participants demonstrated lack of response to aspirin as measured by VerifyNow and urinary 11-dehydro-thromboxane B2; 2 of 29 demonstrated lack of response as measured by light transmission aggregometry. Imprecision was <10% for the PFA-100 and VerifyNow. Concordance was high (>90%) between all assays. Neither aspirin dose (80 vs 325 mg) nor timing between final dose of aspirin and blood draw (2–4 vs 20–24 h) affected any of the assays. Conclusions: Light transmission aggregometry, PFA-100, VerifyNow, and urinary 11-dehydro-thromboxane B2 are all sensitive to the effects of aspirin in healthy individuals. Variables such as aspirin dose, timing between final dose of aspirin and blood collection, and imprecision do not affect the ability of the assays to detect aspirin effect on platelet function.
Evaluation of the Impact of Hematocrit and Other Interference on the Accuracy of Hospital-Based Glucose Meters
Karon, Brad S. , Griesmann, Laurie D, Scott, Renee, Bryant, Sandra C. , DuBois, Jeffrey A., Shirey, Terry, Presti, Steven, Santrach, Paula J.

Diabetes Technology & Therapeutics | February 8, 2008 | Volume: 10 | Issue: 2 | Pages: 111-120

10.1089/dia.2007.0257 Get It

Devices for Monitoring Heparin and Protamine in the Operating Room
Santrach, Paula J.

Seminars in Cardiothoracic and Vascular Anesthesia | June 21, 2007 | Volume: 7 | Issue: 4 | Pages: 379-385

10.1177/108925320300700403 Get It

Ongoing monitoring of heparin anticoagulation is an essential component of many cardiothoracic and vascular surgical procedures in order to prevent significant thrombotic and hemorrhagic complications. The classic test to assess high-dose (>1 unitlmL) heparin anticoagulation is the activated clotting time. Although simple to perform, the activated clotting time has many variations and can be affected by a number of nonanalytical and patient-related factors. Correlation with the heparin concentration may be poor. Alternatively, other test systems assess the individual patient's responsiveness to heparin in order to customize the heparin administration and subsequent protamine neutralization. The choice of test and system depends on the clinical application and the desired outcome. Regulatory and accreditation standards govern this type of testing; modern instrumentation can facilitate compliance with these standards. Understanding of the nature of the test and its performance under a variety of conditions is critical for proper interpretation.
Redefinition of Myocardial Infarction
Roger, Véronique L. , Killian, Jill M. , Weston, Susan A., Jaffe, Allan S. , Kors, Jan A. , Santrach, Paula J., Tunstall‐Pedoe, Hugh , Jacobsen, Steven J. , Jaffe, Allan S.

Circulation | August 15, 2006 | Volume: 114 | Issue: 8 | Pages: 790-797

10.1161/circulationaha.106.627505 Get It

Background— The 2000 European Society of Cardiology/American College of Cardiology definition for myocardial infarction (MI) combines ischemic symptoms, electrocardiographic changes, and troponin rather than creatine kinase levels. The use of troponins will increase the detection of MI by a magnitude to be quantified, and the clinical acceptance of the new definition is unknown. Method and Results— Subjects presenting to an Olmsted County facility with a troponin T value ≥0.03 ng/mL between November 2002 and March 2005 were prospectively classified through the use of standardized MI criteria, relying on cardiac pain, Minnesota coding of the ECG, and troponin, creatine kinase, and its MB fraction measured simultaneously. Through the use of dynamic changes in troponin, 538 MIs were identified versus 327 with creatine kinase and 427 with only the MB fraction of creatine kinase. This represents a 74% (95% confidence interval [CI], 69% to 79%) increase above the number of MIs identified with creatine kinase and a 41% (95% CI, 37% to 46%) increase above the number identified with criteria including only its MB fraction. When relying on single values of troponin, increases in the number of MIs were always large but varied widely according to the threshold used for troponin. Cases meeting only troponin-based criteria were less likely to have electrocardiographic ST-segment elevation and had better survival than those identified with previous criteria. Clinician diagnoses mentioned MI in 42% (95% CI, 34% to 49%) of cases meeting only troponin-based criteria versus 74% (95% CI, 69% to 78%) for MIs meeting the previous criteria ( P <0.001). Conclusions— The prospective application of the new criteria in the community results in a large increase in the number of MIs and a change in case mix. The clinical acceptance of the new criteria is incomplete, and studies that rely exclusively on dismissal diagnoses to assess MI rates may underestimate the burden of disease as presently defined.
Comparison of Blood-conservation Strategies in Cardiac Surgery Patients at High Risk for Bleeding
Nuttall, Gregory A. , Oliver, William C., Ereth, Mark H. , Santrach, Paula J., Bryant, Sandra C. , Orszulak, Thomas A., Schaff, Hartzell V.

Anesthesiology | November 10, 2003 | Volume: 92 | Issue: 3 | Pages: 674-682

10.1097/00000542-200003000-00010 Get It

Background Aprotinin and tranexamic acid are routinely used to reduce bleeding in cardiac surgery. There is a large difference in agent price and perhaps in efficacy. Methods In a prospective, randomized, partially blinded study, 168 cardiac surgery patients at high risk for bleeding received either a full-dose aprotinin infusion, tranexamic acid (10-mg/kg load, 1-mg x kg(-1) x h(-1) infusion), tranexamic acid with pre-cardiopulmonary bypass autologous whole-blood collection (12.5% blood volume) and reinfusion after cardiopulmonary bypass (combined therapy), or saline infusion (placebo group). Results There were complete data in 160 patients. The aprotinin (n = 40) and combined therapy (n = 32) groups (data are median [range]) had similar reductions in blood loss in the first 4 h in the intensive care unit (225 [40-761] and 163 [25-760] ml, respectively; P = 0.014), erythrocyte transfusion requirements in the first 24 h in the intensive care unit (0 [0-3] and 0 [0-3] U, respectively; P = 0.004), and durations of time from end of cardiopulmonary bypass to discharge from the operating room (92 [57-215] and 94 [37, 186] min, respectively; P = 0.01) compared with the placebo group (n = 43). Ten patients in the combined therapy group (30.3%) required transfusion of the autologous blood during cardiopulmonary bypass for anemia. Conclusions The combination therapy of tranexamic acid and intraoperative autologous blood collection provided similar reduction in blood loss and transfusion requirements as aprotinin. Cost analyses revealed that combined therapy and tranexamic acid therapy were the least costly therapies.
Comparison of LightCycler PCR, Rapid Antigen Immunoassay, and Culture for Detection of Group A Streptococci from Throat Swabs
Uhl, J. R., Adamson, Steven C., Vetter, Emily A., Schleck, Cathy D. , Harmsen, William S. , Iverson, L. K., Santrach, Paula J., Henry, Nancy K., Cockerill, Franklin R.

Journal of Clinical Microbiology | January 7, 2003 | Volume: 41 | Issue: 1 | Pages: 242-249

10.1128/jcm.41.1.242-249.2003 Get It

ABSTRACT We compared the performance characteristics of a real-time PCR method, the LightCycler Strep-A assay (Roche Applied Science, Indianapolis, Ind.), to those of a rapid antigen immunoassay, the Directigen 1-2-3 Group A Strep Test kit (BD Diagnostic Systems, Sparks, Md.), and a standard culture method for detection of group A streptococci (GAS) from 384 throat swabs. The LightCycler PCR produced more positive results ( n = 58) than either culture ( n = 55) or the Directigen immunoassay ( n = 31). The results of the LightCycler PCR and the Directigen method were independently compared to the results of the accepted “gold standard,” bacterial culture. The sensitivities, specificities, and positive and negative predictive values for this comparison were as follows: for the Directigen method, 55, 99, 97, and 93%, respectively; for the LightCycler PCR, 93, 98, 88, and 99%, respectively. In no case was a throat swab positive by both the LightCycler PCR and the Directigen method but negative by culture. The medical histories of patients whose throat swabs were negative by culture but positive by either the LightCycler PCR ( n = 7) or the Directigen method ( n = 1) were reviewed. All of these patients had signs or symptoms compatible with GAS disease, and therefore, all of these discordant positive results (along with positive results by either the Directigen method or the LightCycler PCR that agreed with the culture results) were counted as true positives for statistical analysis. For this analysis, the LightCycler PCR detected more true-positive results than the culture method (58 versus 55 swabs); however, this difference was not statistically significant ( P = 0.5465). In contrast, statistically significantly more true-positive results occurred by culture than by the Directigen method (55 versus 31 swabs; P < 0.0001) and by the LightCycler PCR than by the Directigen method (58 versus 31 swabs; P < 0.0001). The LightCycler PCR is a suitable stand-alone method for the detection of GAS from throat swabs. Additionally, this method requires less than half the personnel time and the procedure can be completed in considerably less time (∼1 h) than our standard approach (up to 2 days) for detection of GAS in throat swabs (i.e., testing by the Directigen method with negative results verified by culture).