Impact of Point-of-care Allogeneic Red Blood Cell Washing on Markers of Transfusion-related Respiratory Complications: A Phase II Randomized Clinical Trial
Background: Transfusion-related acute lung injury (TRALI) and transfusion-associated circulatory overload (TACO) are leading causes of transfusion-related morbidity and mortality. Soluble factors in erythrocyte supernatant may increase risk for these complications. The authors hypothesized that point-of-care allogeneic erythrocyte washing may be an effective intervention to mitigate elevations in soluble factors as well as physiologic responses associated with transfusion-associated respiratory complications in the setting of cardiac surgery. Methods: This is a two-center, nonblinded, randomized clinical trial evaluating point-of-care washed versus standard issue allogeneic erythrocyte transfusions administered during or on the day of cardiac surgery. The primary analysis was performed via modified intention to treat. The primary outcomes assessed were changes in intermediate markers of lung injury as well as cardiopulmonary physiologic responses to erythrocyte transfusion. Secondary outcomes included the duration of intensive care unit and hospital stay, durations of mechanical ventilation and oxygen supplementation, presence of TRALI or TACO, and mortality. Results: Among 154 analyzed patients (81 washed, 73 standard issue), the median age was 66 yr, and 77 (50.0%) were women. The median (interquartile range) number of allogeneic erythrocyte units transfused on the day of surgery was 3.0 (2.0 to 5.0) in the washed erythrocyte group and 3.0 (2.0 to 4.0) in the standard issue group (P = 0.13). No between-group differences were identified in any of the assessed recipient lung injury biomarkers (all P values > adjusted alpha). Durations of intensive care unit stay (median [interquartile range], 3.0 [2.0 to 5.0] vs. 3.0 [2.0 to 4.0] days; P = 0.117) and hospital length of stay (12.0 [9.0 to 17.0] vs. 12.0 [9.0 to 17.0] days; P = 0.801) were similar, as were the number of ventilator-free days at day 28 (27.0 [27.0 to 27.0] vs. 27.0 [26.0 to 27.0]; P = 0.699) and oxygen-free days at day 28 (24.0 [19.0 to 26.0] vs. 24.0 [22.0 to 26.0]; P = 0.400). No significant differences were noted in mortality rate or in incidence rates for TRALI, TACO, and acute kidney injury. Conclusions: Among patients undergoing cardiovascular surgery with high risk of erythrocyte transfusion, point-of-care washing of allogeneic erythrocyte transfusions did not mitigate changes in intermediate markers of lung injury or cardiopulmonary physiologic responses to erythrocyte transfusion and was not associated with improved clinical outcomes.
Clinical and pathological features of graft‐versus‐host disease after liver transplantation: A case report and review of the literature
A 59‐year‐old female developed symptoms of graft‐versus‐host disease 3½ weeks after liver transplantation for primary biliary cirrhosis. Symptoms of graft‐versus‐host disease included fever, erythroderma with bullae formation, and mucosal surface ulceration. Donor lymphocytes were present in the peripheral blood. Despite treatment with equine antilymphoblast globulin, steroids and, eventually, cyclosporine withdrawal, she developed neutropenia and succumbed to sepsis. At autopsy, she had marked lymphocyte depletion involving the bone marrow and both native and donor origin lymph nodes. As expected, the liver was normal. The clinical and pathological features were remarkably similar to those of the few other reported cases of graft‐versus‐host disease after liver transplantation and transfusion‐associated graft‐versus‐host disease; therapy is usually ineffective, and progression of disease leads to pancytopenia and death from sepsis.
A-373 Comparison of the CoaguChek ® and Coag-Sense ® PT2 Meter Point of Care INR Devices
Abstract Background Warfarin monitoring may be done at the point-of-care (POC) at home, in a clinic environment, or be performed using plasma specimens in a central laboratory. With a goal of standardizing International Normalization Ratio (INR) measurements and improving data integrity by enabling electronic transmission of results from any location, we evaluated two POC INR devices against an internal plasma INR reference method. Methods We conducted a multicenter study to test the accuracy of two commercially available point of care devices: Coag-Sense PT2 Meter (Coagusense, Inc., Fremont, CA) and CoaguChek XS Pro or XS Plus (Roche Diagnostics, Indianapolis, IN) compared with plasma INR values among warfarin treated patients. Bias and linear regression analysis were assessed for device-plasma INR comparisons. Warfarin dosing decisions were assessed for each device compared to an internal plasma INR reference method (Instrumentation Laboratories ACLTOP 500, 550, 750 analyzers (Werfen Diagnostics, Bedford MA) in one of three CLIA-certified laboratories. The thromboplastin used at our institution for INR measures is HemosIL RecombiPlasTin 2G (R2G) reagent (Werfen Diagnostics, Bedford MA) which has an International Sensitivity Index (ISI) of 1.0. Results Two hundred ninety-nine warfarin patients treated across three Mayo Clinic sites agreed to participate in the study. Common anticoagulant indications were atrial fibrillation (63.9%), venous thromboembolism (21.7%) and heart valve prosthesis (15.4%) with a 2.0–3.0 INR target range for 93.6% of patients. For the CoaguChek devices, 81.3% of values fell within 0.2 INR units of plasma INR referent and 95.3% within 0.4 units. The correlation between CoaguChek whole blood and plasma INR was excellent (R2 = 0.93). For the Coag-Sense device, 34.1% of values fell within 0.2 INR units and 60.2% within 0.4 INR units of plasma INR values, with a slightly weaker correlation between Coag-Sense whole blood and plasma INR (R2 = 0.83; P < 0.0001). Mean (± standard deviation) deviation from plasma INR was 0.04 ± 0.2 for CoaguChek compared to 0.4 ± 0.3 for Coag-Sense (P < 0.0001). The difference between POC devices was largely attributed to systematic negative bias between Coag-Sense and ACL TOP plasma INR values. Using the plasma INR as the reference method for dosing decision making, appropriate dosing recommendations would have occurred for 97.7% of CoaguChek and 81.6% of Coag-Sense results. Conclusion Compared to our institution's plasma reference method, INR values obtained from the CoaguChek devices (XS Pro and XS Plus) exhibited less systematic bias compared to the Coag-Sense values. This translates to greater percentage of concordant management decisions between POC and laboratory plasma INR methods when the CoaguChek device is used.
A Blinded Randomized Trial Comparing Standard Activated Clotting Time Heparin Management to High Target Active Clotting Time and Individualized Hepcon HMS Heparin Management in Cardiopulmonary Bypass Cardiac Surgical Patients
Abstract A device that would provide a rapid evaluation of hemostasis would greatly aid physicians in making scientific decisions regarding transfusion therapy; especially with perioperative bleeding. We performed a prospective in-vitro study with reconstituted, recalcified whole blood (n = 6) separated into samples containing specific deficiencies in platelets, plasma, lyophilized platelets and lyophilized plasma such that the concentrations of the specific platelet or plasma were 0%, 10%, 30%, 50%, and 100%. The whole blood was obtained from consenting healthy volunteers. Samples from the various concentrations of the reconstituted blood were subjected to the following point of care coagulation tests: activated clotting time (ACT), thromboelastogram (TEG), laboratory prothrombin time (PT), laboratory activated partial thromboplastin time (APTT) and Signature+ PT. ACT’s were performed for each of four celite doses (1.5 mg, 3.0 mg, 6.0 mg and 12 mg celite). The four dose celite ACT’s were performed in duplicate and the mean recorded. The TEG was performed in duplicate, and the mean was recorded. The signature+ PT was performed in duplicate, and the mean recorded. The laboratory PT, aPTT, Platelet Count and Fibrinogen were performed once each. ACT values were analyzed within each of the three preparations using analysis of variance. This assessed the strength of the relationship between blood constituent concentration and ACT, and determined whether this relationship differed across varying amounts of celite. Other coagulation parameters including TEG (mA), PT and APTT were analyzed using analysis of variance with a single term for blood constituent concentration. This model determined the strength of the relationship between these coagulation parameters and blood constituent concentration. In addition, the kaolin activated TEG and the signature+ PT was evaluated to determine the strength of the relationship between these tests and the variations in platelet and plasma concentrations. There was a significant correlation between the plasma, platelets and lyophilized plasma concentrations and ACT results (all p < 0.001). There was a significant correlation between plasma platelets and lyophilized plasma and the TEG MA and angle (all p < 0.028). There was a significant correlation between laboratory PT and APTT and plasma, platelets, and lyophilized plasma, lyophilized platelets (all p < 0.001). There was a significant correlation between the Signature+ PT and plasma, lyophilized platelets, and lypholized plasma and platelets (all p < 0.005), (figure 1). A better point of care coagulation device that is based on in-vitro additions of various therapies, and comparison of their effects on coagulation tests may provide better treatment of the bleeding patient. The Signature+ PT could provide the endpoint for such a device whereas the ACT was nonspecific and had a small change in results with large changes in plasma concentration. The additional benefit of lypholized plasma to behave similarly to human plasma may allow such a device to be built. Figure Figure
Vision, mission, and values: From concept to execution at Mayo Clinic
Mayo Clinic displays steadfast commitment to patient care, referral relations, and health care quality through institutional examples of unique, value-add endeavors that are under way with the Mayo Clinic Patient Experience Subcommittee and the Referring Physician Office. In this article, we share the Mayo Model of Care and patient stories that embody the 8 Mayo Clinic values of respect, compassion, integrity, healing, teamwork, excellence, innovation, and stewardship. The Mayo founders imparted to their staff the passion for patient care by encouraging a fair and just culture for its employees. This culture allows the creation, maintenance, and improvement of clinical care, research studies, and educational curricula, which in turn propagate the mission–“To inspire hope and contribute to health and well-being by providing the best care to every patient through integrated clinical practice, education, and research.”
Looking Under the Streetlight? A Framework for Differentiating Performance Measures by Level of Care in a Value-Based Payment Environment
The majority of quality measures used to assess providers and hospitals are based on easily obtained data, focused on a few dimensions of quality, and developed mainly for primary/community care and population health. While this approach supports efforts focused on addressing the triple aim of health care, many current quality report cards and assessments do not reflect the breadth or complexity of many referral center practices. In this article, the authors highlight the differences between population health efforts and referral care and address issues related to value measurement and performance assessment. They discuss why measures may need to differ across the three levels of care (primary/community care, secondary care, complex care) and illustrate the need for further risk adjustment to eliminate referral bias. With continued movement toward value-based purchasing, performance measures and reimbursement schemes need to reflect the increased level of intensity required to provide complex care. The authors propose a framework to operationalize value measurement and payment for specialty care, and they make specific recommendations to improve performance measurement for complex patients. Implementing such a framework to differentiate performance measures by level of care involves coordinated efforts to change both policy and operational platforms. An essential component of this framework is a new model that defines the characteristics of patients who require complex care and standardizes metrics that incorporate those definitions.
Fresh and Citrated Whole-Blood Specimens Can Produce Different Thromboelastography Results in Patients on Extracorporeal Membrane Oxygenation
Abstract Objectives: To compare thromboelastography (TEG) tracings obtained from fresh and citrated whole-blood samples in patients on extracorporeal membrane oxygenation (ECMO) or after cardiopulmonary bypass and in healthy volunteers. Methods: Samples of fresh and citrated whole blood were analyzed for 25 patients and 4 healthy volunteers. Thromboelastography analysis was performed in both plain and heparinase cups. Results: In 5 of 6 patients on ECMO, use of citrated samples resulted in apparent partial or complete heparin reversal. In TEG tracings from patients following cardiopulmonary bypass, there was a slight hypercoagulable appearance in the citrated sample. No differences were noted between fresh and citrated samples from healthy volunteers whose blood was spiked with heparin. Conclusions: In some patients on ECMO, use of samples collected in sodium citrate tubes for TEG analysis results in significant artifacts, which could lead to heparin overdosing in these patients.
Major histocompatibility complex class II alleles and the course and outcome of MS