Background: Thrombelastography (TEG) is an established but labor intensive method for assessing global hemostasis for the management of bleeding and thrombotic risk in surgical, cardiovascular, and trauma patients. We performed the initial validation study of the first true point-of-care TEG, the CORA® (COagulation Resonance Analyzer or TEG-6S system). CORA uses resonance-frequency viscoelasticity measurements and a disposable multi-channel microfluidic cartridge to assess hemostasis and response to antiplatelet therapy. Methods: TEG assays (n=5,100) were performed from the blood of healthy volunteers (n=160) and patients undergoing coronary revascularization (n=300) collected at 3 hospitals. Quality controls were also assayed. The performance of the TEG-6S system was compared with the conventional TEG 5000 system in accordance with Clinical Laboratory Standards Institute Guidelines. Results: Regression analysis demonstrated a strong correlation (R) between the two systems by all standard measures and a lower coefficient of variation (CV %) with the CORA system at all hospitals (Table). Receiver operating characteristic (ROC) curve analysis showed an excellent correlation between platelet mapping methods (AUC≥0.90, p<0.001) and there was a substantial agreement for measuring antiplatelet response to aspirin (k=0.67, agreement=87%) and P2Y12 inhibitors (k=0.69, agreement=86%). Conclusion: The new point-of-care TEG-6S system is associated with improved precision, greater ease of use, and a strong correlation as compared to the conventional TEG 5000 system. The TEG-6S will facilitate future trials of personalized antiplatelet therapy and improve the assessment of bleeding and thrombotic risk in cardiovascular, surgical, and trauma patients.
In-Vitro Evaluation of the Multiple Coagulation Test System (MCTS).
Abstract A device that would provide a rapid evaluation of hemostasis would greatly aid physicians in making scientific decisions regarding transfusion therapy; especially with perioperative bleeding. We performed a prospective in-vitro study with reconstituted, recalcified whole blood (n = 6) separated into samples containing specific deficiencies in platelets, plasma, lyophilized platelets and lyophilized plasma such that the concentrations of the specific platelet or plasma were 0%, 10%, 30%, 50%, and 100%. The whole blood was obtained from consenting healthy volunteers. Samples from the various concentrations of the reconstituted blood were subjected to the following point of care coagulation tests: activated clotting time (ACT), thromboelastogram (TEG), laboratory prothrombin time (PT), laboratory activated partial thromboplastin time (APTT) and Signature+ PT. ACT’s were performed for each of four celite doses (1.5 mg, 3.0 mg, 6.0 mg and 12 mg celite). The four dose celite ACT’s were performed in duplicate and the mean recorded. The TEG was performed in duplicate, and the mean was recorded. The signature+ PT was performed in duplicate, and the mean recorded. The laboratory PT, aPTT, Platelet Count and Fibrinogen were performed once each. ACT values were analyzed within each of the three preparations using analysis of variance. This assessed the strength of the relationship between blood constituent concentration and ACT, and determined whether this relationship differed across varying amounts of celite. Other coagulation parameters including TEG (mA), PT and APTT were analyzed using analysis of variance with a single term for blood constituent concentration. This model determined the strength of the relationship between these coagulation parameters and blood constituent concentration. In addition, the kaolin activated TEG and the signature+ PT was evaluated to determine the strength of the relationship between these tests and the variations in platelet and plasma concentrations. There was a significant correlation between the plasma, platelets and lyophilized plasma concentrations and ACT results (all p < 0.001). There was a significant correlation between plasma platelets and lyophilized plasma and the TEG MA and angle (all p < 0.028). There was a significant correlation between laboratory PT and APTT and plasma, platelets, and lyophilized plasma, lyophilized platelets (all p < 0.001). There was a significant correlation between the Signature+ PT and plasma, lyophilized platelets, and lypholized plasma and platelets (all p < 0.005), (figure 1). A better point of care coagulation device that is based on in-vitro additions of various therapies, and comparison of their effects on coagulation tests may provide better treatment of the bleeding patient. The Signature+ PT could provide the endpoint for such a device whereas the ACT was nonspecific and had a small change in results with large changes in plasma concentration. The additional benefit of lypholized plasma to behave similarly to human plasma may allow such a device to be built. Figure Figure
In Remembrance of Hiroshi Takeshita, MD, Pioneering Neuroanesthesiologist
Abstract Background: Transfusion-associated circulatory overload (TACO) is a leading cause of transfusion-related fatalities, but its incidence and associated patient and transfusion characteristics are poorly understood. To inform surgical transfusion practice and to begin mitigating perioperative TACO, the authors aimed to define its epidemiology. Methods: In this retrospective cohort study, the medical records of adult patients undergoing noncardiac surgery with general anesthesia during 2004 or 2011 and receiving intraoperative transfusions were screened using an electronic algorithm for identification of TACO. Those patients who were screened as high probability for TACO underwent rigorous manual review. Univariate and multivariate analyses evaluated associations between patient and transfusion characteristics with TACO rates in a before-and-after study design. Results: A total of 2,162 and 1,908 patients met study criteria for 2004 and 2011, respectively. The incidence of TACO was 5.5% (119 of 2,162) in 2004 versus 3.0% (57 of 1,908) in 2011 ( P < 0.001), with comparable rates for men (4.8% [98 of 2,023]) and women (3.8% [78 of 2,047]) ( P = 0.09). Overall, vascular (12.1% [60 of 497]), transplant (8.8% [17 of 193]), and thoracic surgeries (7.2% [10 of 138]) carried the highest TACO rates. Obstetric and gynecologic patients had the lowest rate (1.4% [4 of 295]). The incidence of TACO increased with volume transfused, advancing age, and total intraoperative fluid balance (all P < 0.001). Conclusions: The incidence of perioperative TACO is similar to previous estimates in nonsurgical populations. There was a reduction in TACO rate between 2004 and 2011, with incidence patterns remaining comparable in subgroup analyses. Future efforts exploring risk factors for TACO may guide preventive or therapeutic interventions, helping to further mitigate this transfusion complication.
The hibernating 13-lined ground squirrel as a model organism for potential cold storage of platelets
Hibernating mammals have developed many physiological adaptations to extreme environments. During hibernation, 13-lined ground squirrels ( Ictidomys tridecemlineatus) must suppress hemostasis to survive prolonged body temperatures of 4–8°C and 3–5 heartbeats per minute without forming lethal clots. Upon arousal in the spring, these ground squirrels must be able to quickly restore normal clotting activity to avoid bleeding. Here we show that ground squirrel platelets stored in vivo at 4–8°C were released back into the blood within 2 h of arousal in the spring with a body temperature of 37°C but were not rapidly cleared from circulation. These released platelets were capable of forming stable clots and remained in circulation for at least 2 days before newly synthesized platelets were detected. Transfusion of autologous platelets stored at 4°C or 37°C showed the same clearance rates in ground squirrels, whereas rat platelets stored in the cold had a 140-fold increase in clearance rate. Our results demonstrate that ground squirrel platelets appear to be resistant to the platelet cold storage lesions observed in other mammals, allowing prolonged storage in cold stasis and preventing rapid clearance upon spring arousal. Elucidating these adaptations could lead to the development of methods to store human platelets in the cold, extending their shelf life.
Measurement of Shear-Activated Platelet Aggregate Formation in Non-Anticoagulated Blood: Utility in Detection of Clopidogrel–Aspirin-Induced Platelet Dysfunction
We studied the ability of a new instrument, the PlaCor PRT that measures shear-induced platelet aggregation in fingerstick, non-anticoagulated blood without added agonists, to detect platelet dysfunction ex vivo. Platelet reactivity time (PRT) and whole blood aggregation (WBA) were measured in 160 healthy volunteers, before and after aspirin and in 170 participants with established vascular disease or risk factors thereof treated with aspirin ± clopidogrel. Pretreatment PRT and WBA were significantly correlated (collagen r = −.63; arachidonate r = −.65; P < .0001). Following aspirin, the mean PRT increased from 82 to 142 seconds ( P < .0001), and in participants treated with clopidogrel–aspirin, the mean PRT (286 seconds, n = 65) was significantly longer than with aspirin alone (166 seconds, n = 105; P < .001). Only 13% of PRTs of participants treated with clopidogrel and aspirin were within the normal range. We conclude that the PlaCor PRT is a simple, rapid, point-of-care instrument that compares favorably with published descriptions of other platelet function instruments.
Impairment of diaphragm muscle force and neuromuscular transmission after normothermic cardiopulmonary bypass: effect of low-dose inhaled CO
Cardiopulmonary bypass (CPB) is associated with significant postoperative morbidity, but its effects on the neuromuscular system are unclear. Recent studies indicate that even relatively short periods of mechanical ventilation result in significant neuromuscular effects. Carbon monoxide (CO) has gained recent attention as therapy to reduce the deleterious effects of CPB. We hypothesized that 1) CPB results in impaired neuromuscular transmission and reduced diaphragm force generation; and 2) CO treatment during CPB will mitigate these effects. In adult male Sprague-Dawley rats, diaphragm muscle-specific force and neuromuscular transmission properties were measured 90 min after weaning from normothermic CPB (1 h). During CPB, either low-dose inhaled CO (250 ppm) or air was administered. The short period of mechanical ventilation used in the present study (∼3 h) did not adversely affect diaphragm muscle contractile properties or neuromuscular transmission. CPB elicited a significant decrease in isometric diaphragm muscle-specific force compared with time-matched, mechanically ventilated rats (∼25% decline in both twitch and tetanic force). Diaphragm muscle fatigability to 40-Hz repetitive stimulation did not change significantly. Neuromuscular transmission failure during repetitive activation was 60 ± 2% in CPB animals compared with 76 ± 4% in mechanically ventilated rats ( P < 0.05). CO treatment during CPB abrogated the neuromuscular effects of CPB, such that diaphragm isometric twitch force and neuromuscular transmission were no longer significantly different from mechanically ventilated rats. Thus, CPB has important detrimental effects on diaphragm muscle contractility and neuromuscular transmission that are largely mitigated by CO treatment. Further studies are needed to ascertain the underlying mechanisms of CPB-induced neuromuscular dysfunction and to establish the potential role of CO therapy.
Microporous Polysaccharide Hemospheres Do Not Enhance Abdominal Infection in a Rat Model Compared with Gelatin Matrix